Page 71
CHAPTER 3 SYSTEM DATA PROGRAMMING Trunk Data Programming (For Adjunct Analog) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 63 DESCRIPTION DATA Specify the DTMF Sender release timing to the trunk route. (1) (2)YY=46 00-63 : Trunk Route No. 0:2sec. 1:4sec. 2:6sec. 3:8sec. 4:12sec. 5:14sec. 6:16sec. 7:10sec. Specify the designated seizure of trunks on each station basis. (1) (2)YY=98 00-63 : Trunk Route No. 0 : Allowed Specify the COT card Terminating Imped- ance. (1) (2)YYY=100 00-63 :...
Page 72
NEAX2000 IVS2WCS System Manual (PCS)Page 64ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming WCS FEATURE PROGRAMMING Announcement-PS No Answer/Announcement-PS Out of Cell See the WCS Features and Specifications. DESCRIPTION DATA Assign a Digital Announcement Trunk (DAT) circuit number to the required LEN. NOTE 1:The DAT circuit No. must be as- signed to the first LEN (Level 0), the third LEN (Level 2), the fifth LEN (Level 4), and the seventh LEN (Level 6) of each LT...
Page 73
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 65 DESCRIPTION DATA Specify the duration of message for Announcement-PS Out of Cell/PS Power Off. (1) (2)Y=0 84 01-99: 4-396 sec. in 4 sec. increments If no data is set, the default setting is 116-120 seconds. Specify the message reply timer for Announcement-PS No Answer. NOTE:CM41 Y=0>01 is effective only when CM08>085 is set to 0. (1) (2)Y=0 86 01-99: 4-396 sec. in 4 sec....
Page 74
NEAX2000 IVS2WCS System Manual (PCS)Page 66ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming To record/replay/delete a message: There are two methods to record/replay/delete a message from a PS or a station. (1) To record/replay/delete a message from a station or a PS by dialling an access code assigned by CM20, do the following programming. This method is available only for the IntegratedType. (2) To record/replay/delete a message from a PS by dialling “1”, “2”, “3”, do...
Page 75
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 67 For operating procedure, see the following pages. DESCRIPTION DATA Assign the Class of Service for the Announcement Service to a certain PS station. NOTE:By this method, while a PS is specified to “Allowed” to record/ replay/delete a message by CM15 YYY=110, the PS cannot originate a call. Specify to “Restricted” by CM15 YYY=110 again after a message is completed to record/replay/...
Page 76
NEAX2000 IVS2WCS System Manual (PCS)Page 68ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming Operating Procedure for Announcement Service (1) By dialling predetermined access cord from a station or a PS (For Integrated Type) To replay an announcement: 1. Dial the access code to replay the announcement assigned by CM20. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4. Receive a message. 5. Press the END key. To record an...
Page 77
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 69 (2) By dialling “1”, “2”, “3”, from a PS (For Integrated Type and AdjunctType) To replay an announcement: 1. Dial “2”. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4. Receive a message. 5. Press the END key. To record an announcement: 1. Dial “1”. 2. Dial the Digital Announcement Trunk Circuit Number (000-127). 3. Press the SEND key. 4....
Page 78
NEAX2000 IVS2WCS System Manual (PCS)Page 70ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming Call Forwarding-Not Available Refer to the WCS Features and Specifications. DESCRIPTION DATA Assign the destination VMS station for Call Forwarding-Not Available. (1) (2)YY=20 00-63: Tenant No. of Virtual PS X-XXXXXXXX: VMS Station No. Assign the access code to set/cancel Call Forwarding when the incoming call is not available, and set the access code to replay the message. (1)...
Page 79
CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 71 Calling Name Display-PS Refer to the WCS Features and Specifications. Refer to the following manuals for the name display feature programming. Feature Programming Manual : Alphanumeric Display, Caller ID Class, Guest Name Display CCIS System Manual : Calling Name Display-CCIS DESCRIPTION DATA Specify the terminal kind of the PS as “D termPS II”. (1) (2)YY=15 X-XXXXXXXX: PS station...
Page 80
NEAX2000 IVS2WCS System Manual (PCS)Page 72ND-70920 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING WCS Feature Programming Group Call-Automatic Conference (6/10-Party) Refer to the WCS Features and Specifications. DESCRIPTION DATA Assign a Conference Trunk card number to the required LEN.(1) (2)000-763 : LEN 0-7 (PIM0-7) + 00-63 (Port No.) ED00-ED03: Conference Trunk Card No. Assign the stations which belongs to each paging group, and their number within the group. A maximum of 9 stations can be paged...