CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk Data Programming (For Adjunct Analog)
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 63
DESCRIPTION DATA
Specify the DTMF Sender release timing
to the trunk route.
(1)
(2)YY=46
00-63 : Trunk Route No.
0:2sec.
1:4sec.
2:6sec.
3:8sec.
4:12sec.
5:14sec.
6:16sec.
7:10sec.
Specify the designated seizure of trunks
on each station basis.
(1)
(2)YY=98
00-63 : Trunk Route No.
0 : Allowed
Specify the COT card Terminating Imped-
ance.
(1)
(2)YYY=100
00-63 :...

Page 72

NEAX2000 IVS2WCS System Manual (PCS)Page 64ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
WCS FEATURE PROGRAMMING
Announcement-PS No Answer/Announcement-PS Out of Cell
See the WCS Features and Specifications.
DESCRIPTION DATA
Assign a Digital Announcement Trunk
(DAT) circuit number to the required LEN.
NOTE 1:The DAT circuit No. must be as-
signed to the first LEN (Level 0),
the third LEN (Level 2), the fifth
LEN (Level 4), and the seventh
LEN (Level 6) of each LT...

Page 73

CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 65
DESCRIPTION DATA
Specify the duration of message for
Announcement-PS Out of Cell/PS Power
Off.
(1)
(2)Y=0
84
01-99: 4-396 sec. in 4 sec. increments
If no data is set, the default setting is
116-120 seconds.
Specify the message reply timer for
Announcement-PS No Answer.
NOTE:CM41 Y=0>01 is effective only
when CM08>085 is set to 0.
(1)
(2)Y=0
86
01-99: 4-396 sec. in 4 sec....

Page 74

NEAX2000 IVS2WCS System Manual (PCS)Page 66ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
To record/replay/delete a message:
There are two methods to record/replay/delete a message from a PS or a station.
(1) To record/replay/delete a message from a station or a PS by dialling an access code
assigned by CM20, do the following programming.
This method is available only for the IntegratedType.
(2) To record/replay/delete a message from a PS by dialling “1”, “2”, “3”, do...

Page 75

CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 67
For operating procedure, see the following pages.
DESCRIPTION DATA
Assign the Class of Service for the
Announcement Service to a certain PS
station.
NOTE:By this method, while a PS is
specified to “Allowed” to record/
replay/delete a message by
CM15 YYY=110, the PS cannot
originate a call. Specify to
“Restricted” by CM15 YYY=110
again after a message is
completed to record/replay/...

Page 76

NEAX2000 IVS2WCS System Manual (PCS)Page 68ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
Operating Procedure for Announcement Service
(1) By dialling predetermined access cord from a station or a PS (For Integrated Type)
To replay an announcement:
1. Dial the access code to replay the announcement assigned by CM20.
2. Dial the Digital Announcement Trunk Circuit Number (000-127).
3. Press the SEND key.
4. Receive a message.
5. Press the END key.
To record an...

Page 77

CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 69
(2) By dialling “1”, “2”, “3”, from a PS (For Integrated Type and AdjunctType)
To replay an announcement:
1. Dial “2”.
2. Dial the Digital Announcement Trunk Circuit Number (000-127).
3. Press the SEND key.
4. Receive a message.
5. Press the END key.
To record an announcement:
1. Dial “1”.
2. Dial the Digital Announcement Trunk Circuit Number (000-127).
3. Press the SEND key.
4....

Page 78

NEAX2000 IVS2WCS System Manual (PCS)Page 70ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
Call Forwarding-Not Available
Refer to the WCS Features and Specifications.
DESCRIPTION DATA
Assign the destination VMS station for Call
Forwarding-Not Available.
(1)
(2)YY=20
00-63: Tenant No. of Virtual PS
X-XXXXXXXX: VMS Station No.
Assign the access code to set/cancel Call
Forwarding when the incoming call is not
available, and set the access code to
replay the message.
(1)...

Page 79

CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 71
Calling Name Display-PS
Refer to the WCS Features and Specifications.
Refer to the following manuals for the name display feature programming.
Feature Programming Manual : Alphanumeric Display, Caller ID Class, Guest Name Display
CCIS System Manual : Calling Name Display-CCIS
DESCRIPTION DATA
Specify the terminal kind of the PS as
“D
termPS II”.
(1)
(2)YY=15
X-XXXXXXXX: PS station...

Page 80

NEAX2000 IVS2WCS System Manual (PCS)Page 72ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
WCS Feature Programming
Group Call-Automatic Conference (6/10-Party)
Refer to the WCS Features and Specifications.
DESCRIPTION DATA
Assign a Conference Trunk card number to
the required LEN.(1)
(2)000-763 : LEN
0-7 (PIM0-7) +
00-63 (Port No.)
ED00-ED03: Conference Trunk Card
No.
Assign the stations which belongs to each
paging group, and their number within the
group. A maximum of 9 stations can be
paged...