Page 61

CHAPTER 3 SYSTEM DATA PROGRAMMING
PS Data Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 53
PS DATA PROGRAMMING
Perform the following procedure after completing SYS ID Assignment and ZT Authorization.
DESCRIPTION DATA
Assign a PS station No. to the required
vir tual PS LEN.
NOTE 1:When the Expansion Memory
card (PZ-M537) is not mounted
on the MP card, the 1st data is
000-127.
NOTE 2:For Roaming PS, max. 5 digits
PS station number should be
assigned.(1)
(2)000-255 : Virtual PS...

Page 62

NEAX2000 IVS2WCS System Manual (PCS)Page 54ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
PS Data Programming
DESCRIPTION DATA
Assign the Service Restriction Class to
each PS station.
(1)
(2)YY=02
X-XXXXXXXX : PS station No.
XX ZZ
XX : Service Restriction
Class A (00-15 )
When providing Roaming service, specify
the Service Restriction Class for Roaming
service data download.
NOTE 1:Assign the same Service
Restriction Class data to the PS
station number and the Vi rtual
LC station number
(For...

Page 63

CHAPTER 3 SYSTEM DATA PROGRAMMING
PS Data Programming
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 55
 When changing the PS operation data
If you change the PS operation data in this section which hasbeen already downloaded to a PS,
do PS data download (CM1D YY=20 second data: 1) again.
DESCRIPTION DATA
Download the PS operation data to each
PS by assigning the 2nd data 1.
(1)
(2)YY=20
X-XXXXXXXX : PS station No.
1 : To be executed
Refer to “D
termPS User Manual”.
NOTE 1:All steps for...

Page 64

NEAX2000 IVS2WCS System Manual (PCS)Page 56ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Virtual Line/Trunk Data Programming (For Integrated/Adjunct CCIS)
VIRTUAL LINE/TRUNK DATA PROGRAMMING
(FOR INTEGRATED/ADJUNCT CCIS)
This programming is required for Integrated Type or Adjunct Type (CCIS Interface).
DESCRIPTION DATA
Assign a vir tual station number to the
required LEN.
NOTE 1:The Vir tual LEN must be as-
signed from the last LEN 763.
NOTE 2:Do not assign the same station
No. to the Vir...

Page 65

CHAPTER 3 SYSTEM DATA PROGRAMMING
Virtual Line/Trunk Data Programming (For Integrated/Adjunct CCIS)
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 57
DESCRIPTION DATA
The following data is set automatically by the virtual line-trunk path setting of CM5A YY=00.
If you clear CM5A YY=00 setting data, the following data is also cleared automatically.
NOTE:The trunk route data must be assigned by CM35because the trunk route data is
not automatically assigned.
The trunk route of the Virtual...

Page 66

NEAX2000 IVS2WCS System Manual (PCS)Page 58ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Virtual Line/Trunk Data Programming (For Integrated/Adjunct CCIS)
DESCRIPTION DATA
Change the trunk route for the vir tual trunk
number, if required.
(1)
(2)YY=00
256-511: Virtual Trunk No.
00-63 : Trunk No.
Assign the data for the Virtual Line/Trunk
to the trunk route No. assigned by CM30
YY=00.
(1)
(2)YY=00 (Kind of Route)
00-63 : Trunk Route No.
00 : DDD

(1)
(2)YY=01 (Type of Signal)
00-63 : Trunk...

Page 67

CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk Data Programming (For Adjunct Analog)
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 59
TRUNK DATA PROGRAMMING (FOR ADJUNCT ANALOG)
This programming is required for Adjunct Type (Analog Interface).
DESCRIPTION DATA
Assign a trunk number to the required
LEN.(1)
(2)000-763 : LEN
0-7 (PIM0-7) +
00-63 (Port No.)
D000-D255 : Trunk No.
Assign the trunk route number to the trunk
number.
(1)
(2)YY=00 (DP or DTMF)
000-255: Trunk No.
00-63 : Trunk Route No....

Page 68

NEAX2000 IVS2WCS System Manual (PCS)Page 60ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk Data Programming (For Adjunct Analog)
DESCRIPTION DATA
Specify the answer signal from the distant
office for outgoing connection to the trunk
route.
(1)
(2)YY=04
00-63 : Trunk Route No.
1 : Battery Reversal
7 : Answer signal does not arrive
from C.O. Line (Answer timing
shall be set by CM41 Y=0
Function No. 03)
Specify the release signal from the distant
office for an outgoing connection of an...

Page 69

CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk Data Programming (For Adjunct Analog)
NEAX2000 IVS2WCSSystemManual(PCS)
ND-70920 (E), Issue 1.0Page 61
DESCRIPTION DATA
Specify the Sender prepause timing to the
trunk route.
NOTE:To reduce the connecting time, it
is preferable to shor ten the
prepause timing (i.e., second
data=03 (1.5 sec.))
(1)
(2)YY=21
00-63: Trunk Route No.
00: 0 sec. 08 : 6.0 sec.
01: 0.5 sec. 09 : 7.0 sec.
02: 1.0 sec. 10 : 8.0 sec.
03: 1.5 sec. 11 : 9.0 sec.
04: 2.0 sec. 12 : 10.0 sec.
05:...

Page 70

NEAX2000 IVS2WCS System Manual (PCS)Page 62ND-70920 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Trunk Data Programming (For Adjunct Analog)
DESCRIPTION DATA
Specify the DP Make Ratio.
(1)
(2)YY=25
00-63 : Trunk Route No.
0 : 39 % Make Ratio
1 : 33 % Make Ratio
Assign the DTMF signal width to the trunk
route.
NOTE:To reduce the connecting time, it
is recommended to shorten the
DTMF inter-digital Pause timing
(YY=24), i.e., second data=2 (80
ms). YY=26, i.e., second data=0
(64 ms).
(1)
(2)YY=26...