Page 131
CHAPTER 4 CIRCUIT CARD INFORMATION PN-AP00-A (DBM) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 123 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before...
Page 132
NEAX2000 IVS2WCS System Manual (PCS)Page 124ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) PN-24DTA-C (DTI) Locations of Lamps, Switches, and Connectors SENSE RU N MB CRC PCM FRM RMT AIS BL SW1 SW0 JRR1 AISS MAS JPR0 JPS
Page 133
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 125 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Remains lit when detecting PCM signal loss. FRM Red Remains lit when detecting Frame Alignment signal loss. RMT Red Remains lit when receiving Frame Alignment signal loss alarm from a distant...
Page 134
NEAX2000 IVS2WCS System Manual (PCS)Page 126ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-3 Not used 4-F Set the switch to match the AP Number (04-31) to be set by CM05. MB (Toggle SW) NOTE 2 UP For make-busy For normal operation (Continued) F 4 AP No.SW1-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW1-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN
Page 135
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 127 SW0 (Piano Key SW) 1 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 0 input on MP card. OFFSource clock signal from network is not sent to the PLO 0 input on MP card. 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 1 input on MP card. OFFSource clock signal from network is not sent to the PLO 1 input on MP card. 3ONRemote loop-back For normal...
Page 136
NEAX2000 IVS2WCS System Manual (PCS)Page 128ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Piano Key SW) NOTE 41 Not used 2 Not used 3 Not used 4ON AP No. 04-15 OFF AP No. 20-31 JPR0 (Jumper Pin) UPNeutral grounding on the receiving line is provided. Neutral grounding on the receiving line is not provided. JPR1 (Jumper Pin) Line impedance: 100 ohms Left Line impedance: 110 ohms JPS (Jumper Pin) UPNeutral grounding on...
Page 137
CHAPTER 4 CIRCUIT CARD INFORMATION PN-24DTA-C (DTI) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 129 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1:Set the groove on the switch to the desired position. NOTE 2:When the power is on, flip the MB switch to ON (UP position) before...
Page 138
NEAX2000 IVS2WCS System Manual (PCS)Page 130ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) PN-30DTC-A (DTI) Locations of Lamps, Switches, and Connectors SENS RU N MB SW PCM FRM MFRM RMT MRMT AIS BL JP JPSJPR
Page 139
CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) NEAX2000 IVS2WCSSystemManual(PCS) ND-70920 (E), Issue 1.0Page 131 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM when this card is normally operating. PCM Red Remains lit when detecting PCM signal loss. FRM Red Remains lit when detecting Frame Alignment signal loss. MFRM Red Remains lit when detecting Multi-Frame Alignment signal loss on Time Slot 16. RMT Red Remains lit when receiving the alarm from a distant office because Frame...
Page 140
NEAX2000 IVS2WCS System Manual (PCS)Page 132ND-70920 (E), Issue 1.0 CHAPTER 4 CIRCUIT CARD INFORMATION PN-30DTC-A (DTI) Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2 UPFor make-busy For normal operation F 4AP No.SW-8: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW-8: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN