Page 421
Volume, Brightness, and Contrast Controls DSX Software ManualFeatures◆391 Features To set up the display brightness, contrast control, and dial pad illummination presets: 1. [Menu + Display] [Menu + MORE (2 or 3 times) + Dsply]Select the display preset mode. 2.Do one of the following. a.[Contrast] [Cont]• Select the display contrast preset. • When you see Contrast ------, press Volume Up and Volume Down to set the contrast preset (0-8). b.[Brightness + Active] [Brght + Actv]• Select the active...
Page 422
Walking Class of Service 392◆Features DSX Software Manual Walking Class of Service Description Walking Class of Service allows an extension user to temporarily implement their Toll Restriction and Class of Service settings at a co-worker’s keyset. This is normally used to override dialing restrictions at a tele- phone. For example, an executive with an unrestricted phone can walk to any keyset in the building, imple- ment Walking Class of Service, and dial without restriction. After the keyset goes...
Page 423
Walking Class of Service DSX Software ManualFeatures◆393 Features Other Related Features Features Extension Locking (page 166) Extension Locking and Walking Class of Service share the same PIN code. Single Line Telephones (page 305) Walking Class of Service is not available to single line telephone users. Station Message Detail Recording (page 328) When an extension user implements Walking Class of Service and places an outside call, the system assigns the SMDR record to the users’s extension. The...
Page 424
Walking Class of Service 394◆Features DSX Software Manual 4.When you see NEW PIN ACCEPTED: [Exit] [Exit] To change your PIN number (if you already have one assigned): 1. Press INTERCOM and dial ##6. 2.When you see ENTER PIN CODE: • Enter your current PIN number + HOLD. 3.When you see ENTER NEW PIN: • Enter your new PIN number + HOLD. • When entering your PIN number: - CLEAR erases your entire entry. - REDIAL backspaces over (erases) the last digit entered. 4.When you see REENTER NEW PIN: • Con firm...
Page 425
DSX Software ManualIntraMail Features◆395 IntraMail Features IntraMail Features Introduction Introduction How To Use This Chapter This chapter provides detailed information on the IntraMail features. Similar to the Features chapter, the IntraMail features in this chapter are in alphabetical order, like a dictionary. This chapter subdivides each feature de finition into headings as follows: ❥Description Read Description to get an overview of the feature, its bene fit, any special considerations you...
Page 426
Start-Up Programming 396◆IntraMail Features DSX Software Manual Start-Up Programming Start-Up IntraMail Programming 1.Add additional IntraMail mailboxes as required. - In 2141-01: Station Mailbox Type (page 766), enter 1. This enables a Subscriber Mailbox for the extension. - By default in DSX-80/160, the first 16 mailboxes are enabled (extensions 300-315). - By default in DSX-40, the first 8 mailboxes are enabled (extensions 300-307). 1.In 3112-01: Direct Termination in the Day (page 819), enter...
Page 427
Start-Up Programming DSX Software ManualIntraMail Features◆397 IntraMail Features 1.Normally, you should leave the following programs at their default settings: -1312-01: Voice Mail Extension Number (page 624) ( 500-507). - 4101-02: Voice Mail Master Number (page 864) ( 700). - 4111-01: Voice Mail Port Name (page 865) ( VM PORT #). - 4112-02: Operator’s Extension (page 868) ( 300) 6.Review this additional programming (not for Built-In Automated Attendant).
Page 428
Specifications 398◆IntraMail Features DSX Software Manual Specifications Specifications Built-In Automated Attendant Capacities MailboxesRouting Mailboxes: . . . . . . . . . . . . . . . . . . . . 8 Call Routing: . . . . . 8 Announcement: . . . 0 Subscriber:. . . . . . . . . . . . . . . . . . . . . . . . . . . 0 Ring Group Mailboxes: . . . . . . . . . . . . . . . . . 0 UCD Group Mailboxes: . . . . . . . . . . . . . . . . 0 Total: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Ports:2...
Page 429
Application Examples DSX Software ManualIntraMail Features◆399 IntraMail Features Application Examples Examples of Some Common Applications The examples below show some common applications. The chart in the beginning of each example shows: ❥How the relevant programmable options work by default. ❥The Application Summary , which provides the basic steps you need to take to set up the application. Following the chart are the step-by-step instructions for setting up the appl\ ication. Example 1: Set Up...
Page 430
Application Examples 400◆IntraMail Features DSX Software Manual Example 2: Provide Unique Day and Night Dialing Options for Callers 1.Following example 1, set up separate day and night Instruction Menus using Call Rou\ ting Mailboxes 1 and 2. - The day Instruction Menu can say something like: Thank you for calling. For Sales, dial 301. For Technical Support, dial 302. To talk to an operator, dial 0. If you know your party’s extension number, please dial it now. - The night Instruction menu can say...