Page 241
Configure Fujitsu Starlog IntegrationPage 1 of 3VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration feature to work with the Fujitsu Starlog PBX. Refer to the appendixes for reference information about this integration. There are two sections to installing this integration: installing and configuring the VoiceMemo software, and configuring the Fujitsu Starlog PBX. Refer to your Starlogdocumentation for help when...
Page 242
GP 505 Page 2 of 3VoiceMemo Release 5.03 and later Step 7.Set the following phone line exceptions for each line in the line group: Exception Value Descriotion3 2 Dial Tone Detect Time 9 20 Ringing Timeout 25 Y Enable DTMF Column 3 14040 Loop Break Detect Time 14490 In-ring Off Time 148 3In-ring On Time Low 152 1500In-ring Minimum Power 1648 DTMF Output Duration 1762 DTMF Output Level Note:If the VoiceMemo system has the Receptionist II optional feature, the Ringing Timeout (line exception 9) must be 3...
Page 243
GP 505 Page 3 of 3VoiceMemo Release 5.03 and later Step 3.CMC 102: FLGN 2 15 49 109 110 111 112 136Set the following system parameter flags to the indicated values: Value Descrintion 1OPS ring pattern = station ringing (1s on, 3s off) 1Enable message waiting for all 500/2500 sets 10Send filler digit (0) to VoiceMemo when required 1Enable called party auto-disconnect on hangup 1Enable stutter dial tone if no message waiting lamp 0Set voice mail integration pattern zero (0) 3 or4Set to extension length on...
Page 244
Configure AT&T System 25 IntegrationPage 1 of 1VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration optional feature to work with the AT&T System 25 PBX. Refer to the appendixes for reference information about this integration. After completing the steps below, you will need to program your switch to pass in-band call information to the AIP VoiceMemo system. Refer to your PBX manual for additional information. SteD...
Page 245
Configure Northern Telecom NorstarIntegrationGP 507Page 1 of 4 VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration feature to work with the Northern Telecom Norstar KSU. Refer to the appendixes for reference information about this integration. There are two sections to installing this integration: installing and configuring the VoiceMemo software, and configuring the Norstar. Refer to your Norstardocumentation for help...
Page 246
GP 507 Page 2 of 4VoiceMemo Release 5.03 and latei step I7.Refer to the Task List in your VoiceMemo Reference and Corzfguration Manual to find procedures to configure any of the options below for the integration line group. You can reach these options by selecting Other Features from the online Enhanced In-band Menu. lSchedule Company Greetings lEnable Call Placement Message Delivery lConfigure for Transfer to System Attendant lDefine an Administrator’s Mailbox lDefine an Attendant’s Mailbox l Configure...
Page 247
GP 507 Page 3 of 4VoiceMemo Release 5.03 and later Step GD Configure the Northern Telecom Norstar 1.Install VMI modules for all integration lines as instructed in the Norstar Voice Mail Inte$zce Installation Gzriu’e. Connect lines from the Line Jacks on the VMIs to available telephone ports on the KSU. Connect lines from the Terminal Jacks on the VMIs to line card ports on the VoiceMemo system. Plug in the power supplies for the VMIs. Mount the VMIs on the wall after connecting them to both the KSU and...
Page 248
GP 507 Page 4 of 4VoiceMemo Release 5.03 and later Step 6.For Modular DR3 and DR4 systems, ensure that each VMI DN is configured as follows: Under Permissions/Capabilities:Set Lock =NONE Full Handsfree =NO Handsfree Answerback =NO Pick Up Group =NO Page Zone = NO Auxiliary Ringer = NO *.Hotline =NO Priority Call =NO Under Line Access: Answer DN = NO Line Pool Access =NO(If a line will be used for outdialing, set to YES.) Two intercom lines are assigned, with one assigned as the prime line. 7.Program...
Page 249
Configure AT&T Legend IntegrationGP508Page 1 of 1 VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration optional feature to work with the AT&T Legend PBX. After completing the steps below, you will need to program your switch to pass in-band call information to the AU? VoiceMemo system.Refer to your PBX manual for additional information. smReference 1.Install the Enhanced In-band Integration optional feature diskette....
Page 250
GP 509Configure Northern Telecom MTX IntegrationPage 1 of 1 voiceMemoRelease 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration optional feature to work with the Northern Telecom MTX switch. After completing the steps below, you will need to program your switch to pass in-band call information to the AIP VoiceMemo system. Refer to your PBX manual for additional information. SteD 1.Install the Enhanced In-band Integration optional...