Page 231
Task List Page 1 of 1 VoiceMemo Release 5.03 and 5.04A and later TuskProcedure Enhanced In-band Integration Configure an Enhanced In-baud Integration......................................GP502 Configure AT&T Legend Integration.................................................GP508 Configure AT&T System 25Integration.............................................Gl? 506 Configure Fujitsu Omni Integration...................................................GP504 Configure Fujitsu Starlog...
Page 232
Configure an Enhanced In-band IntegrationPage 1 of 1VoiceMemo Release 5.03 and later This procedure describes the steps required to configure your AIP VoiceMemo system with Enhanced In-band Integration. These steps include a Detailed Procedure that is a sample for reference when creating in-band templates for use with your particular switch. Use this procedure if there is no default template set available for your switch. Step 1. 2. 3. 4. 5. 6. 7. 8.Install the Enhanced In-band Integration optional...
Page 233
GP504Configure Omni IntegrationPage 1 of 8 VoiceMemo Release 5.03 and later This procedure summarizes the steps required to install and configure the Enhanced In-band Integration to work with the Omni PBX. Refer to the appendixes for reference information about this integration. There are two sections to installing this integration: installing and configuring the software on the VoiceMemo system, and configuring the Omni PBX. Refer to your Omni documentation for help when configuring the PBX, if...
Page 234
GP 504 Page 2 of 8VoiceMemo Release 5.03 and later step 9.If your VoiceMemo system has Release 5.03 software, set the number of in-band tasks per module to 20% of the number of in-band ports in each module.If your system has Release 5.04 software, the system automatically configures the required number of tasks. 10. Set the following phone line exceptions for each line in the line group: Excention Value Descriution08 10 Dead Line Time-out 24 YEnable Wink Start signaling 32 20 Received DTMF Debounce35...
Page 235
GJ? 504 Page 3 of 8VoiceMemo Release 5.03 and later Stev 5.Use the following RC transactions to add the hardware to the system data base. Select double-height slots to accommodate the EMT cards. RC 221Add a Card CARD CARDTYPEFB NUMBER ---- --------- EMTFB-17201RC 153Add a Trunk *. VoiceMemoMessage Wait TrunksTrunk Physical Trunk Type E&ME&M Supervisory IncomingWinkID Supervisory Outgoing Wink-- @D Configure Trunks for the Enhanced In-band line Group 6.Use the following RC transactions to add the Enhanced...
Page 236
GP 504 Page 4 of 8VoiceMemo Release 5.03 and later SteDRC 212 H OF OLKA s sWH --- YRC211 STA AC TC IE 0 sNS --- YChange/Show Non-Displayable Class of Service 1 R ECD AP EI DH ID MO vIN ENE --- --- YN Change/Show Displayable Class of Service 1 A 0TCN OC M M LE E EN LS R RE s s ST --- --- --- Y YY 7.Use RC 218 to assign a directory number for the Enhanced In-band trunk group. This DN is the destination for all forwarded calls. If your system has the Receptionist II application, it is also the termination...
Page 237
GP 504 Page 5 of 8VoiceMemo Release 5.03 and later Step 8.Use RC 113 to create a “dummy” extension, and then forward that extension to the DN for the Enhanced In-band trunk group with RC 141. This extension is the number that users must dial to retrieve their messages. You should select an easy-to-remember number for this extension. DIR --cos--DIV DIV DIV NUMDNCND DST ID-_------_____---~_--------~~~~~~~YY zzDA VM WhereXXX is the DN for message retrieval from step 7 YY/ZZ is the Basic Class of...
Page 238
G-l? 504 Page 6 of 8 VoiceMemo Release 5.03 and later StepReferenceRC 212Change/Show Non-Displayable Class of Service 1 RH EOF CD AP 00 OL EI DH RN KA ID MO IL ss vIN GY WH ENE --- --- --- --- NNYYRC 211 Change/Show Displayable Class of Service 1 STAA 0AC TCN TC OC M M IE LE E EN OS LS R RE NSS S ST --- --- --- --- NNNN10. Set the following values for the E & M trunk groups. These fields are not accessible through RC transactions. T5841Trunk Group outpulsing delay value = 0 T575 1Trunk Group AIOD...
Page 239
GP 504 Page 7 of 8VoiceMemo Release 5.03 and later step ED Configure User Stations11. Allow user stations to forward to the VoiceMemo system and receive message waiting indication with the following RC transactions. RC 212Change/Show Non-Displayable Class of Service 1 CVM AAA LR ILI LFA VB WB MO DL SX -__ --- YY RC 214Change/Show Non-Displayable Class of Service 2 MESSAGE WAITING LAMP---_--- Y12. Change all user COSs with RC 211 to ahow access to the Enhanced In-band trunk group. 13. Use the following...
Page 240
GP 504Page 8 of 8 VoiceMemo Release 5.03 and later Step15. Forward POTS telephones to the VoiceMemo directory number with RC 141. lSelect the condition for forwarding, most likely “Divert if Busy or No Answer.” lSelect “VMS” as the Destination Type. 16. Tell users with FeaturePhones to forward their phones to the VoiceMemo DN. 17. Force the E & M trunks out of service and put them back into service using Maintenance mode. Reference18. Instruct users to dial the “dummy” extension and enter their...