1.1 This Section describes the Station Message Detail Recording (SMDR) feature of the 
SX-508 DIGITAL Private Automatic Branch Exchange (DPABX). 
1.2 This section has been reissued to incorporate MS55 software. 
1.3 Station Message Detail Recording collects data about each trunk call, outgoing 
and/or incoming, to facilitate analysis of telephone usage for control of costs. The call 
record, one 80-column line of text, is sent to the DPABX Printer Port at the 
completion of the call. This output can be...

Page 652

Station Message Detail Recording 
9104-091-221-NA 
Issue5  221 1-2 Revision 0  

Page 653

Each time a trunk is seized, information about activity on the trunk is collected until the 
trunk is released. If more than one trunk is involved in a call, a separate record is 
generated for each trunk. If a station talks to a trunk, then transfers it to another station, 
only one call record is generated. However, the number of the second station will also 
appear in the record. 
2.1 SMDR records provide information on the following items: 
0 Outgoing and Incoming calls 
e Account Codes (optional) 
e...

Page 654

Station Message Detail Recording 
: The originator of the call is identified in this field. If the originator was 
a station, the numb ears in the field. I he originator was a trunk, the trunk number 
appears, preceded (CO trunk) or an (non-CO trunk). If the Attendant originated 
: An * in this field identifies calls originated or answered by the 
Attendant or Auxiliary Attendant. The field is otherwise blank. 
: This field applies only to outgoing calls. For incoming 
s in this space. The trunk group...

Page 655

: If the call originated within the PABX 
and an Account Code and/or Verified Authorization Code 
(WAC) was entered, the 
Account Code/I/AC appears in this field. Detailed Description 
9104-091-221~NA Issue 5 
Revision 0 221 2-3  1 Long Call 
Z blank: less than 5 min 
- 
5minto14min59s 
% :15minto29min59s 
t : 30 min or more 
2-6 Date mm/dd mm = month (01-12) dd = day (01-31) 
7 space 
8-13 Start Time hh:mmp 
hh = hour mm = minutes 
p = blank (AM) or P (PM), (12-hour mode) 
14 space 
15-22 Duration...

Page 656

Installation of Station Message Detail Recording is as follows: 
0 Determine the required output configuration (e.g., printer parameters). 
e Connect output device (printer, data recorder or modem) to RS-232 Port using 
RS-232 Extender Cable. See Figure 3-1, Control Card Connections or Figure 3-2, 
Control Card 2 (MCC2) Connections for location of RS-232 Port. 
e Program SMDR. See Part 4. 
3.1 The printer must have at least an 80-character line length and accept ASCII 
characters. Table 3-1 shows the...

Page 657

Station Message Detail Recording 
0 
( 0 0 0 1 SPACE 1 0 P 
I 
0 0 0 1 
DC1 ! 
1 A 
1 Q 
I 
221 3-2 Revision 0 
9104-091-221 -NA Issue 5  

Page 658

Installation 
GROUNDING 
/.,/--- BRACKET 
TEST POINTS 
AC NIGHT BELL 
/ RESET SWITCH 
4 
3 STATUS 
2 SWITCH 
5 1 
----. RS-232 PORT 
---‘.J4 
(ATFENDANT CONSOLE) 
7SEGMENT 
DISPLAY 
 CARD 
EXTRACTOR 
EDG BAR 
DD0039 
9104-091-221-NA Issue 5 
Revision 0 
221 3-3  

Page 659

Station Message Detail Recording 
, AC NIGHT BELL 
, RESET SWITCH 
----. RS-232PORT 
-(ATTENDANT CONSOLE] 
7SEGMENT 
DISPLAY 
’ EDG BAR 
DD0039 
- 
221 3-4 
Revision 0 
9104-091-221-NA Issue 5  

Page 660

This Part describes programming options that affect Station Message Detail Recording 
(SMDR). See Section 9104-091-210-NA, Customer Data Entry, for further details. 
4.1 SMDR must be enabled in System Options Programming, Command 100 Register 
14. There are four options: 
e disabled (field c = 0), (this is default) 
0 enabled for incoming trunk calls only (field c = 1) 
e enabled for outgoing trunk calls only (field c = 2) 
* enabled for both incoming and outgoing trunk calls (field c = 3). 
SMDR must...