Page 681
The information contained in this document is believed to be accurate in all respects but is not warranted by Mite1 Corporation (MITEL@). The informa- tion is subject to change without notice and should not be construed in any way as a commitment by Mite1 or any of its affiliates or subsidiaries. Mite1 and its affiliates and subsidiaries assume no responsibility for any errors or omissions in this document. Revisions of this document or new editions of it may be issued to incorporate such changes....
Page 682
Reason for Reissue . . . . . . . . . . . . . . ....................................... 350 l-l Basic Troubleshooting Philosophy . . . ....................................... 350 l-l Control Card Nomenclature . . . . . . . . ....................................... 350 1-1 Line Status LEDs ......................... Card Status LEDs ........................ Control Card 7-Segment Display ............ Console STATUS Key ..................... Alarm Indicators .......................... Alarm LED on...
Page 683
Troubleshooting Procedures and General Maintenance Information Busy-out DTMF Generator (*42) ........................................ 350 5-1 Busy-out DTMF Receiver (*43) ......................................... 350 5-2 Busy-outTrunk(*41) .................................................. 350 5-2 DataDump(*97) ..................................................... 350 5-2 Data Load (“98) ...................................................... 350 5-2 LampTest(“16)...
Page 684
Table of Contents Table 4-7 Peripheral Equipment Troubleshooting ............................ 350 4-8 Table 5-1 Maintenance-Related Attendant Functions ......................... 350 5-3 Table 5-2 Maintenance Equipment Status Display Functions ................... 350 5-4 Table 5-3 Call Processing State and Substate Codes ......................... 350 5-16 9104-091-350-NA Issue 5 Revision 0 V
Page 685
Troubleshooting Procedures and General Maintenance Information vi Revision 0 9104-091-350-NA Issue 5
Page 686
This Section contains information to assist troubleshooting of the SX-508 DPABX (Digital Private Automatic Branch Exchange). The SX-50 system is itself the most important tool in the troubleshooting process. It contains an array of diagnostic tests and equipment status displays to assist maintenance personnel. 1.1 This section has been reissued to incorporate MS55 software. 1.2 This Section uses the following approach to determining the cause of a malfunction: * ACQUIRE relevant information (i.e.,...
Page 687
Troubleshooting Procedures and General Maintenance Information 9104-091-350-NA Issue 5 350 l-2 Revision 0
Page 688
,’ 2.1 Each line or trunk circuit has an associated red status LED on the front face of the circuit card. The SX-50 cover must be removed to see these displays. See Table l-1 and Figure 2-i. 2.2 Each card has a green status LED on its front face located just above the red circuit status LEDs. The SX-50 cover must be removed to see these displays. See Table 2-2 and Figure 2-1. ON - steady Card recognized Diagnostic tests passed 9104-091-350-NA Issue5 Revision 0 350 2-l
Page 689
Troubleshooting Procedures and General Maintenance information 2.3 The Control Card has a red 7-segment display near the lower ri Figure 2-2 and Figure 2-3. The display normally shows a flashing cover must be removed to see this display. See Figure 2-1. edge. See The SX-50 DO0037 2.4 The Console STATUS key provides the following functions on successive keypresses: * Software identity - name and maintenance release number. 0 Engineering Control Information. 350 2-2 Revision 0 9104-091-350~NA...
Page 690
Status and Alarm Indicators * Configuration - the number of LS/GS Trunks, E&M Trunks and Extensions con- nected to the system, but not necessarily programmed. See Table 2-3. * Busy-outs for different equipment types (See Table 2-4). 0 Bell volume and LCD contrast adjustment, LED test. 0 LCD Display test. CO: 16 EM: 00 EXT 024 Number of Extensions BUSY OUTS 00 00 00 00 00 TOTAL 00 DTMF Generator DTMF Receivers Dial Tone Detectors Conference Channels Trunks 1 2.5 There are three alarm...