Page 201

Installation Forms
TABLE 3-19
FORM 13 - TRUNK CIRCUIT DESCRIPTORS
DESCRIPTOR NO. 1TYPECOMMENTS
06
07
0809
12
19
20
21
22
23
24
25Notes: 1. Specify a Trunk Type for the required trunk circuit descriptors. The Trunk Types include:
4-CCT CO, 4-CCT DISA, 6-CCT CO, 6-CCT 
DISA, E&M MODULE, E&M MODULE DISA,
E&M CARD, E&M TRK 
DISA, 2-CCT DID/TIE, 2-CCT TIE DISA, 6-CCT DID, Tl E&M, Tl E&M
DISA, 
Tl DID/TIE, Tl TIE DISA, Tl LS/GS, and Tl CO DISA,
2. The COMMENTS field stores additional information. It is not...

Page 202

SECTION MITL9109-094-206-NATABLE 3-20
FORM 
13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
SHEET 
_ OF _IImpedance (600 Ohms or Complex)
Dictation Trunk 
(Y or N)Notes: 1. 
x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
Descriptors), via the SEL. OPTIONS 
softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The
options can be specified only after a trunk type has been assigned to a trunk circuit
descriptor number,
Page 36 

Page 203

Installation Forms
TABLE 3-20 (CONT’D)
FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
!SHEET _ OF _6-CIRCUIT CO TRUNK andTRUNK CIRCUIT DESCRIPTOR NUMBER (1 
- 25)
6-CIRCUIT
DISAOPTIONS-12-3-4-5-6-7-8-91-0Reverse to Idle 
(Y or N)IFar-End Gives Answer Supervision 
(Y or N)Inhibit Automatic Supervision 
(Y or N)No Seize Alarm 
(Y or N)No Release Alarm 
(Y or N)Toll Office 
(Y or N)~-IInterdigit Timer 300 
- 800 ms (100 ms inc)
Digit 
OUtpUking Ratio (60/40, 80/20, 66/33)Notes: 1. 
JC This form is a nested...

Page 204

SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D)
FORM 
13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS
SHEET 
_ OF _
Ime(Immed, Wink,Delay or Delay
Flash Timer 200 
- 700 ms (IO@ ms inc)Interdigit Timer 300 
+ 800 ms (100 ms inc)Wait for Delay Timer 
300 - 5000 ms
(100 ms inc)Page 38 

Page 205

Installation Forms
TABLE 3-20 (CONT’D)
FORM 13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS
E&M MODULE and
E&M MODULE 
DISA OPTIONS
Remote End is a Satellite 
(Y or N)Remote End is a Satellite with OPS Lines
(Y or N)SHEET 
_ OF _TRUNK CIRCUIT DESCRIPTOR NUMBER (1 
- 25)
-1 -2 -3 -4 -5 -5 -7 -8 -9 -0Notes: 1. 
x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
Descriptors), via the SEL. OPTIONS 
softkeys.2. Specify the hardware options for the selected trunk circuit descriptor...

Page 206

SECTION MITLSI 09-094-206-NATABLE 3-20 (CONT’D)
FORM 
13% - TRUNK CIRCUIT DESCRIPTOR OPTIONS
SHEET OF
Notes: 1. 
# This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
Descriptors), via the SEL. OPTIONS softkeys.
2. Specify the hardware options 
f6r the selected trunk circuit descriptor number. The
options can be specified only after a trunk type has been assigned to a trunk circuit
descriptor number.
Page 40 

Page 207

Installation Forms
TABLE 3-20 (CONT’D)
FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
SHEET 
_ OF _P-CIRCUIT DID/TIE and
Remote Endis aSatellite withOPSLinesNotes: 1. 
x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
Descriptors), via the SEL. OPTIONS 
softkeys.2. Specify the hardware options for the selected trunk circuit descriptor number. The
options can be specified only after a trunk type has been assigned to a trunk circuit
descriptor number.
Page 41 

Page 208

SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D)
FORM 13x 
- TRUNK CIRCUIT DESCRIPTOR OPTIONS
SHEET 
_ OF _II6-CIRCUIT DID
OPTIONS
Wink Timer 
150 - 300 ms (50 ms inc)Remote End is a Satellite 
(Y or N)Remote End is a Satellite With OPS Lines
(Y or N)Notes: 1. 
x This form is a nested form and can only be accessed from Form 13 (Trunk Circuit
Descriptors), via the SEL. OPTIONS softkeys.
2. Specify the hardware options for the selected trunk circuit descriptor number. The
options can be specified only after...

Page 209

Installation Forms
TABLE 3-20 (CONT’D)
FORM 13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
SHEET_OF _Outgoing 
Start Type (Immed, Wink, Delay or Delay
Integ)Digit Outpulsing Ratio 
(60/40, 80/20, 66/33)
Outpulse Delay Timer 100 - 2000 ms
(100 ms inc)
Flash Timer 
200 - 700 ms (100 ms inc)Interdigit Timer 300 
- 800 ms (100 ms inc)
Wait for Delay Timer 
300 - 6000 ms
(100 ms inc)
Remote end is a satellite 
(Y or N)Remote end is a satellite with OPS Lines
(Y or N)Notes: 1. 
x This form is a nested form and can...

Page 210

SECTION MITL9109-094-206-NATABLE 3-20 (CONT’D)
FORM 
13x - TRUNK CIRCUIT DESCRIPTOR OPTIONS
SHEET 
_ OF _
NoRelease Alarm(Y or N)Toll Office 
(Y or N)Is this a CO 
(Y or N)DTMF 
(Y or N)Disconnect Timer 
150 - 300 ms (50 ms inc)Release Acknowledge Timer 2 
- 120 sGuard Timer 
200 - 1000 (100 ms inc)
Start Type (Immed, Wink or Delay)
Debounce Timer 20 - 150 ms (IO ms inc)Wink Timer 
150 - 300 ms (50 ms inc)
OUtgOing Stat? Type (Immed, Wink, Delay or Delay
Integ)Digit Outpulsing Ratio 
(60/40, 60/20,...