Installation Forms
TABLE 3-12
FORM 08 - ATTENDANT LDN ASSIGNMENTS
Bay/Slt/Cct:Console Extension Number:
Bay/Slt/Cct:Console Extension Number:
Notes: 1. There are a maximum of 11 consoles
2. The directory number is a maximum of five digits. It links this form to Form 19, Call
Rerouting Table, where the actual call type is defined for each directory number. The
directory number programmed for 
softkey 2 shares the softkey with calls to the con-
sole’s extension number (as defined in the EXT NUM field of...

Page 192

SECTION MITL9109-094-206-NATABLE 3-13
FORM 09 
- STATION/SUPERSET@ TELEPHONES
SHEET 
_ OF _Notes: Notes for this form follow on next page.
Page 26 

Page 193

Installation Forms
Notes: 1.2.
3.
4.
5.
6.
7.NOTES FOR FORM 09
STATION/SUPERSET TELEPHONES
Specify the Tenant Group, Extension Number, COS number and COR number for each
device.
Specify the device type in the TYP field as a Rotary Dial or DTMF set (STN), 
SUPERSETtelephone (SET) or Call Announce Port (CAP). The CAP can be a Station Circuit, a
SUPERSET telephone circuit, COV circuit, or OPS circuit. Hardware restrictions prevent a
digital ONS circuit from being a CAP.
Specify the physical location (by the...

Page 194

SECTION MITL9109-094-206-NATABLE 3-14
FORM 
09x - SUPERSET TELEPHONE LINES
SHEET 
_ OF _EXTENSION NUMBER:SUPERSET 3TM telephoneSUPERSET 4@ telephone zz:ISVPERSET 
3TMDN telephone ____
SVPERSET 4TMDN telephone ____
* See note 4.
Notes: 1. 
x This form is anested form and can only be accessed fromForm 09
(Station/SUPERSET Telephones).
2. KEY 01 is the Prime Line and cannot be modified.
3. If the set is a 
SUPERSET 3DN or a SUPERSET 4DN Telephone, the form shows 12 keys
(01 to 12).
4. If the set is a...

Page 195

installation Forms
NOTES FOR FORM 09x (CONT’D)
SUPERSET TELEPHONE LINES
5. Line Select keys can be programmed as line appearances. Select the appearance type
and variants from the following list:
TYPE
KEY= Key Line
Multiple= Multiple Call Line
Personal= Personal Outgoing Line
DTS= Direct Trunk Select
Private= Private Trunk
Speed Call (default for keys 2 
- 15)
DIRECTION
BOTH= Both Way
IN= In OnlyRING
IMMED =
Immediate Ring
DELAY =
Delay Ring
NO= No Ring
SECRETARIAL (Multiple call lines only)
NON=...

Page 196

SECTION MITL9109-094-206-NATABLE 3-15
FORM 10 
- PICKUP GROUPS
SHEET 
_ OF _I
IIIIIIIIINotes: 1. The system supports a maximum of 50 Pickup Groups and each Pickup Group supports
a maximum of 50 members.
2. The order in which the Pickup Group members are entered is not significant.
3. Pickup Group members are restricted to extension numbers of Rotary Dial or DTMF sets
or Prime Line numbers of SUPERSEJ telephones. Attendant Consoles are not allowed in
Pickup Groups.Page 30 

Page 197

Installation Forms
TABLE 3-16
FORM 11- DATA CIRCUIT DESCRIPTORS
Notes: 1. The number of circuits assigned to a particular descriptor is automatically displayed by
the system.2. The comments field stores additional information. It is not used by the system and can
have a maximum of 20 characters.Page 31 

Page 198

SECTION MITL9109-094-206-NATABLE 3-17
FORM 
11~ - DATA CIRCUIT DESCRIPTOR OPTIONS
DATA CIRCUIT DESCRIPTOR NUMBER (1 
-r 25)
OPTION-1 -2 -3 -4 -5 -6 -7 -8 -9 -0Session Inactivity Disconnect Timer
O-255 minutes
Guard Timer
O-99 seconds
Minimum Baud Rate
110, 150, 300, 600, 1200, 2400, 4800, 9600, or 19200
Default Baud Rate
110, 150, 300, 600, 1200, 2400, 4800, 9600, or 19200
Maximum Baud Rate
110, 150, 300, 600, 1200, 2400, 4800, 9600, or 19200
Always Use Default Baud Rate When Called
YES or NO
DTR Off...

Page 199

Installation Forms
TABLE 3-17 (CONT’D)
FORM 1 lx - DATA CIRCUIT DESCRIPTOR OPTIONS
ASYNC: XOFF character
O-127, Decimal value of ASCII code
ASYNC: Break Key Function
SYS ATT or TRANSPARENT
ASYNC: PBX Attention Character
0 
- 127, Decimal value of ASCII code
ASYNC: Parity
ODD, EVEN or NONE
ASYNC: Character Length
7 or 8; 8 bits implies no parity
ASYNC: Number of Stop Bits
1 or 2
ASYNC: Autobaud to Host Character 1
0 
- 127, Decimal value of ASCII code
ASYNC: Autobaud to Host Character 2
0 
- 127, Decimal...

Page 200

SECTION MITL9109-094-206-NATABLE 3-18
FORM 12 
- DATA ASSIGNMENT
SHEET 
_ OF _EXT NUM COS COR CDN DTE AVL HOTLINE COMMENTS
Notes: 1. When a DNI card is programmed in the System Configuration form (Form 01), the
systemautomaticallyenterstheBay/Slot/CircuitlocationsinForm 09,
Station/SUPERSET Assignment, and in Form 12, Data Assignment.
2. Enter Bay/Slot/Circuit numbers of the programmed device.3. Enter the type of device programmed. The available types are 
DATASET 1101, DATASET1102, 
DATASET 1103,...
Start reading Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual

Related Manuals for Mitel SX 200 DIGITAL Pabx Shipping, Receiving, And Installation Information Manual

All Mitel manuals