Page 191
Installation Forms TABLE 3-12 FORM 08 - ATTENDANT LDN ASSIGNMENTS Bay/Slt/Cct:Console Extension Number: Bay/Slt/Cct:Console Extension Number: Notes: 1. There are a maximum of 11 consoles 2. The directory number is a maximum of five digits. It links this form to Form 19, Call Rerouting Table, where the actual call type is defined for each directory number. The directory number programmed for softkey 2 shares the softkey with calls to the con- sole’s extension number (as defined in the EXT NUM field of...
Page 192
SECTION MITL9109-094-206-NATABLE 3-13 FORM 09 - STATION/SUPERSET@ TELEPHONES SHEET _ OF _Notes: Notes for this form follow on next page. Page 26
Page 193
Installation Forms Notes: 1.2. 3. 4. 5. 6. 7.NOTES FOR FORM 09 STATION/SUPERSET TELEPHONES Specify the Tenant Group, Extension Number, COS number and COR number for each device. Specify the device type in the TYP field as a Rotary Dial or DTMF set (STN), SUPERSETtelephone (SET) or Call Announce Port (CAP). The CAP can be a Station Circuit, a SUPERSET telephone circuit, COV circuit, or OPS circuit. Hardware restrictions prevent a digital ONS circuit from being a CAP. Specify the physical location (by the...
Page 194
SECTION MITL9109-094-206-NATABLE 3-14 FORM 09x - SUPERSET TELEPHONE LINES SHEET _ OF _EXTENSION NUMBER:SUPERSET 3TM telephoneSUPERSET 4@ telephone zz:ISVPERSET 3TMDN telephone ____ SVPERSET 4TMDN telephone ____ * See note 4. Notes: 1. x This form is anested form and can only be accessed fromForm 09 (Station/SUPERSET Telephones). 2. KEY 01 is the Prime Line and cannot be modified. 3. If the set is a SUPERSET 3DN or a SUPERSET 4DN Telephone, the form shows 12 keys (01 to 12). 4. If the set is a...
Page 195
installation Forms NOTES FOR FORM 09x (CONT’D) SUPERSET TELEPHONE LINES 5. Line Select keys can be programmed as line appearances. Select the appearance type and variants from the following list: TYPE KEY= Key Line Multiple= Multiple Call Line Personal= Personal Outgoing Line DTS= Direct Trunk Select Private= Private Trunk Speed Call (default for keys 2 - 15) DIRECTION BOTH= Both Way IN= In OnlyRING IMMED = Immediate Ring DELAY = Delay Ring NO= No Ring SECRETARIAL (Multiple call lines only) NON=...
Page 196
SECTION MITL9109-094-206-NATABLE 3-15 FORM 10 - PICKUP GROUPS SHEET _ OF _I IIIIIIIIINotes: 1. The system supports a maximum of 50 Pickup Groups and each Pickup Group supports a maximum of 50 members. 2. The order in which the Pickup Group members are entered is not significant. 3. Pickup Group members are restricted to extension numbers of Rotary Dial or DTMF sets or Prime Line numbers of SUPERSEJ telephones. Attendant Consoles are not allowed in Pickup Groups.Page 30
Page 197
Installation Forms TABLE 3-16 FORM 11- DATA CIRCUIT DESCRIPTORS Notes: 1. The number of circuits assigned to a particular descriptor is automatically displayed by the system.2. The comments field stores additional information. It is not used by the system and can have a maximum of 20 characters.Page 31
Page 198
SECTION MITL9109-094-206-NATABLE 3-17 FORM 11~ - DATA CIRCUIT DESCRIPTOR OPTIONS DATA CIRCUIT DESCRIPTOR NUMBER (1 -r 25) OPTION-1 -2 -3 -4 -5 -6 -7 -8 -9 -0Session Inactivity Disconnect Timer O-255 minutes Guard Timer O-99 seconds Minimum Baud Rate 110, 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 Default Baud Rate 110, 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 Maximum Baud Rate 110, 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 Always Use Default Baud Rate When Called YES or NO DTR Off...
Page 199
Installation Forms TABLE 3-17 (CONT’D) FORM 1 lx - DATA CIRCUIT DESCRIPTOR OPTIONS ASYNC: XOFF character O-127, Decimal value of ASCII code ASYNC: Break Key Function SYS ATT or TRANSPARENT ASYNC: PBX Attention Character 0 - 127, Decimal value of ASCII code ASYNC: Parity ODD, EVEN or NONE ASYNC: Character Length 7 or 8; 8 bits implies no parity ASYNC: Number of Stop Bits 1 or 2 ASYNC: Autobaud to Host Character 1 0 - 127, Decimal value of ASCII code ASYNC: Autobaud to Host Character 2 0 - 127, Decimal...
Page 200
SECTION MITL9109-094-206-NATABLE 3-18 FORM 12 - DATA ASSIGNMENT SHEET _ OF _EXT NUM COS COR CDN DTE AVL HOTLINE COMMENTS Notes: 1. When a DNI card is programmed in the System Configuration form (Form 01), the systemautomaticallyenterstheBay/Slot/CircuitlocationsinForm 09, Station/SUPERSET Assignment, and in Form 12, Data Assignment. 2. Enter Bay/Slot/Circuit numbers of the programmed device.3. Enter the type of device programmed. The available types are DATASET 1101, DATASET1102, DATASET 1103,...