Page 151
Shipping, Receiving, and Installation Information 7. UPGRADING AN EXISTING SX-200 PABX TO AN SX-200 DIGITAL PABX Strategy7.01The control cabinet will be installed beside the existing SX-ZOOPABX cabinet, equipped with the new attendant console, new stations, tru-rks, or features for Bays, 1, 2 or 3, and powered up. All testing can be completed and the new database entered with CDE, including all equipment in the existing SX-200 system. The existing SX-200 DIGITAL PABX is then reconfigured as a Peripheral...
Page 152
SECTION MITL9109-094-200-NA CHART 7-l SX-200 PABX UPGRADE TO SX-200 DIGITAL PABX This upgrade and installation procedure is to be performed only by qualified personnel who have successfully completed a MITEL Installation and Maintenance Course for the SX-200 DIGITAL PABX.StepActionComments 1.Unpack the Control cabinet and place it in its assigned location according to Chart5-4. 2.Relocate the #6 AWG system ground to Note: Connect a temporary jumper the common ground stud in the Control between the...
Page 153
Shipping, Receiving, and installation Information CHART 7-1 (CONT’D) SX-200 PABX UPGRADE TO SX-200 DIGITAL PABXStepActionComments 10.Connect the printer cable, if present, to J29 on the Control Shelf backplane. 11.Remove all rtxisting consoles from the system and repack them. 12.Connect a PFT monitor wire between PI8of the Interconnect Card and TBI-7 of the PFT card in an SX-200 cabinet. In an SX-100 cabinet, connect the PFT monitor wire between PI8 and J14. 13.If peripheral shelf card assignments are...
Page 155
Shipping, Receiving, and installation Information 8. UPGRADE A 336 PORT PABX TO A 672 PdRT PERIPHERAL CABINET General 8.01This upgrade and installation procedure is to be performed onlyby qualified personnel who have successfully completed a MITEL Installation and Maintenance Course for the SX-200 DIGITAL PABX. 8.02This procedure identifies how to convert an existing 336-port PABX Control cabinet to a 672-port PABX Peripheral cabinet; the actual installation of the 672-port PABX is described in Section...
Page 156
SECTION MITL9109-094-200-NACHART 8-l (CONT’D) CONVERT A 336 PORT CONTROL CABINET TO A 672 PORT PERIPHERAL CABINET StepAction Comments 4.Open the front door, and put on the antistatic wrist strap. Remove all cards from the cabinet, storing each in an antistatic bag. Place in a safe and secure location until required for installation. 5. 6.Remove the panel (if present) above the upper card file (2 screws). Remove the upper (Peripheral) cardfile (if present). - Identify and record all ground connections...
Page 157
Step (Cognt’d 10. 11. 12. 13.Action - Remove the PFT harness assembly from the PFT card and tie wrap harness to Control cardfile.Comments Shipping, Receiving, and Installation Information CHART 8-l (Cont’d) CONVERT A 336 PORT CONTROL CABINET TO A 672 PORT PERIPHERAL CABINET - Remove the temperature sensor assembly, if present, and tie wrap it and its wiring harness to the Control cardfile. - Remove the screws at the front, and slide the cardfile and attached assemblies out.Remove the #6 AWG ground wire...
Page 158
SECTION MITL9109-094-200-NACHART 8-l (Cont’d) CONVERT A 336 PORT CONTROL CABINET TO A 672 PORT PERIPHERAL CABINET StepAction Comments 14.Install the larger Blanking panel at the topfront of the cabinet using 2 IO-32 screws provided. 15.Remove the cover plate on the right side of the cable exit panel at the back of the cabinet. If the panel was a flat one replace the cover plate with the cable adapter plate. Fasten theplate with 6 #6-32 self-tapping screws with an external tooth lockwasher under each...