Page 221

Installation Forms
TABLE 3-29
FORM 22 - ARS: MODIFIED DIGIT TABLE
SHEET 
_ OF _
IENTRY NUM 1 QTY TO DELETE 1DIGITS TO BE INSERTED
COMMENTS
-1-
-2
-3
-4
-5
-6
-7
-8
-9
-5
-6
-7
-8
-9
-0Notes: 1. Specify the number of digits (a maximum of 25) that will be deleted for each Entry
Number (1 - 100).
2.Specify digits (a maximum of 38) that will be inserted for each Entry Number. Special
number sequences that can be included in the DIGITS TO BE INSERTED field are:
*I = Pause 5 Seconds
*2 = Wait for Dial Tone
*3...

Page 222

SECTION MITL91D9-094-206-NATABLE 3-30
FORM 23 
- ARS: ROUTE DEFINITION
SHEET 
_OF_Notes: 1. Valid Route numbers are 1 through 200.
2. Assign a Trunk Group number, COR Group number (optional) and a Mod Digit Entry
number (1-c 100) for each Route number.3. The COR GROUP number links this form to Form 20, COR Group Definition. Members of
the listed COR Group are denied access to the route.
4. The COMMENTS field stores a maximum of 20 characters.Page 56 

Page 223

Installation Forms
TABLE 3-31
FORM 24 - ARS: ROUTE LISTS
SHEET 
_ OF _
-7
-8
-9
-0Notes: 1. Specify the Route List numbers (01 
- 100).
2. Assign the required Route numbers for each Route List number. Route selection occurs
in the order that the Route numbers are entered.3. Indicate the expensive routes with an “E” in the WT (Warning Tone) field. An enabled
warning tone is represented by ON on the display.Page 57 

Page 224

SECTION MITL9109-094-206-NATABLE 3-32
FORM 25 
- ARS: ROUTE PLANS
ROUTE PLAN: 
-Route Plan Function:
SHEET _ OF _06 1
ROUTE 
PLAN---Route Plan Function:
TIME
ZONE
01
02
03
05
06DAY 2
START HOURDNE 1DAY ZONE 2DAY ZONE 3
ROUTE LIST START HOUR ROUTE LIST START HOUR ROUTE LIST
ROUTE PLAN: 
-Route Plan Function:
Notes: 1. There are a maximum of 50 Route Plan numbers.
2. Specify the starting hour and Route List number for each time zone.Page 58 

Page 225

Installation Forms
TABLE 3-33
FORM 26 - ARS: DIGIT STRINGS
SHEET 
_ OF _
IIIINotes: 1. List the digits that will be dialed for external trunk access in the LEADING DIGITS field.
The system supports a maximum of 100 Leading Digit entries. Each entry can be a
maximum of five digits. Leading digits must not conflict with feature access codes.
Users with COS Option 244 (Room Status Applies) and Option 33 (Room Status) of
internal enabled are denied calls to these numbers.
2. Specify which entries require...

Page 226

SECTION MITL9109-094-206-NATABLE 3-34
FORM 
26s - ARS: NESTED DIGIT STRINGS
SHEET 
_ OF _LEADING DIGITS:RETURN DIAL 
TONE (YES/NO):
RESTRICTED COR GROUP: -Notes: Notes for this form follow on next page.
Page 60 

Page 227

Installation Forms
Notes: 1.2.
3.
4.
5.
NOTES FOR FORM 26++ARS: NESTED DIGIT STRINGS
Specify the leading digits, the presence of dial tone and the restricted COR Groups.
Specify the user dialed digits that require analysis, BEFORE routing occurs, in the DIGITS
TO BE ANALYZED field. The total number of digits in the DIGITS TO BE ANALYZED field,
the 
QTY TO FOLLOW field and LEADING DIGITS field in the previous form (refer to Table
3-33, ARS: Digits Strings) cannot exceed 26. Specify the number of user...

Page 228

SECTION MITL9109-994-206-NATABLE 3-35
FORM 27 
- ARS: MAXIMUM DIALED DIGITS
24
25
Notes: 1. The purpose of this form is to accommodate countries with open numbering plans such
as Malaysia.2. The default value of UNLIMITED is used in North America.
Page 62 

Page 229

Installation Forms
TABLE 3-36
FORM 28 - FORM ACCESS RESTRICTION DEFINITION
FORM NAME
INSTMAlNTl MAINTZSUPERATT
01= SYSTEM CONFIGURATIONR/W
02 = FEATURE ACCESS CODES
I I IR/W
I I
03 = COS DEFINE
04 = SVS 
OPTIONS/SVS TIMERSR/W
R/W
05 = TENANT INTERCONNECTIONR/W
06 = TENANT NIGHT SWITCHINGR/W
07 = CONSOLE ASSIGNMENTSR/W
08 = 
AlTENDANT LDN ASGN
09 = 
STATION/SUPERSET TELEPHONES
10=PICKUP GROUPSR/W
R/W
R/W
11= DATA CIRCUIT DESCRIPTORR/W
12 = DATA ASSIGNMENTR/W
13= TRUNK CIRCUIT DESCRIPTORSR/W
14 =...

Page 230

SECTION MITL9109-094-206-NATABLE 3-36 (CONT’D)
FORM 28 
- FORM ACCESS RESTRICTION DEFINITION
43 = 
Tl LINK ASSIGNMENTR/W
44 = NETWORK SYNCHRONIZATIONR/W
Notes: 1. The Installer (INST) and the Maintenance 1 
(MAINTl) levels of access default to a
ReadNVrite (R/W) access for each form. All other levels of access default to No Access
(none).2. The Installer level of access has the highest degree of access and cannot be modified.
3. Specify an access type: Read/Write (R/W), Read Only (R) or No Access (none)...