Page 251
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-83 If Set Too Low Hang-up strings may be ignored if the switch cannot send the digits fast enough to meet this value. This may cause excessive off hook times between calls. Min 0 Max 30000 Default 0 Requires Restart Yes Switch-Dependent Yes Set by Integrator Yes Hangup Detection Parameters Minimum Duration for Drop in Loop Current (LCDTIME) This parameter specifies the amount of time, in 10...
Page 252
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-84 If Set Too High If this parameter is set too high, the system records silence. Also, switches could detect a port as available and mistakenly pass incoming calls to a port on which the system is recording silence (missed disconnect). In this case, a new caller would append to the previous recording. If Set Too Low If this parameter is set too low, callers could be cut off during recording due to natural...
Page 253
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-85 Min — Max — Default No Requires Restart Yes Switch-Dependent Yes Set by Integrator No Port Parameters Ring Count This parameter specifies the number of rings each port must hear before it answers an incoming call. For example, if Ring Count is set to 2, a port must ring twice before it comes off hook to answer an incoming call. When/How to Use Enter the Ring Count in the corresponding...
Page 254
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-86 Port Parameters Outbound This parameter determines whether each port is allowed to perform outbound events: message indicators, message notification, AMIS, fax, V-Edit, Visual Mailbox, future delivery, auto forward, and wake-up calls. When/How to Use Enable Outbound for each port that should be allowed to perform outbound events. If you want to dedicate the port to receive outbound calls, disable...
Page 255
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-87 Port Parameters Outbound Usage Permitted/Msg Delivery This parameter determines whether each port is allowed to perform message delivery events—message notification and future delivery. To use message notification and future delivery, you must enable at least one port for Msg Delivery. Msg Delivery is dimmed if Outbound is disabled. When/How to Use Enable Msg Delivery for each port that should be...
Page 256
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-88 When/How to Use Enable Msg Indicator for each port that should be allowed to perform message indicator events. If you want to dedicate the port to message indicator events, disable Inbound as well as all Outbound Usage Permitted options except Msg Indicator. If you experience delayed indicator events, increase the number of ports enabled for Msg Indicator. If you disable a port for Msg Indicator that was...
Page 257
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-89 Related Parameters/Features If the sentinel does not support OctelNet and AMIS, the OctelNet/AMIS checkbox is disabled for all ports. You must enable an outbound network option (Casual AMIS, Administered AMIS, OctelNet) in the subscribers’ Class of Service for outbound network messaging to be available. You must enable Permit Outbound and enter the system location information on the Networking tab in...
Page 258
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-90 Port Parameters Outbound Usage Permitted/ Application This parameter determines whether each port is allowed to support external applications (Visual Mailbox, V-Edit). To support one or both of these external applications, you must enable at least one port for Applications. Applications is dimmed if Outbound is disabled. When/How to Use Enable Applications for each port that should be allowed to...
Page 259
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-91 Min — Max — Default Yes Requires Restart Yes Switch-Dependent Yes Set by Integrator No Voice System Parameters Maximum Call Duration (PROGTIME) This parameter specifies the maximum amount of time, in minutes, the messaging system allows a call to occupy a port before it disconnects the call without warning. When/How to Use Use caution when setting this parameter. If callers are...
Page 260
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-92 Related Parameters/FeaturesW hen RECDTMF is set to a higher value than PLAYDTMF, the RECDTMF value is used for both. If Set Too HighIf this parameter is set too high, the system may not recognize DTMF tones and will not interrupt the prompt. If the DTMF is not recognized, OctelNet messages may be missed. If Set Too LowIf this parameter is set too low, the system may interpret voice data as DTMF. If the DTMF is...