Page 241
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-73 Message Delivery Parameters Number of Seconds to Wait before Message Delivery This parameter defines the number of seconds the messaging system waits to voice the Message Notification phrase after a subscriber answers the phone. When/How to Use For most systems, the default value should be sufficient. Some switches require a few seconds, however, to establish a voice path after an extension goes off...
Page 242
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-74 If Set Too High If this parameter is set too high, switches send dial tone for a specified time before they time out and stop sending it. If DTONW AIT is set too high, the switch timeout is exceeded and DTONW AIT is never completed. Consequently, the outbound event is never initiated. If Set Too Low If DTONW AIT is set too low, and the switch does not send constant, stable dial tone immediately, the...
Page 243
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-75 Message Indicator Parameters Message Indicator Prefix ON Code This parameter specifies the code the messaging system must insert at the beginning of the dialing string to turn on a message indicator. When/How to Use This parameter is set when the Integrator utility is run, if required by the switch. Related Parameters/Features Some switches require both a prefix code and a suffix code. W hen...
Page 244
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-76 Message Indicator Parameters Message Indicator Suffix ON Code This parameter specifies the code the messaging system must insert after the extension number is dialed to turn on the Message Indicator. When/How to Use This parameter is set when the Integrator utility is run, if required by the switch. Related Parameters/Features Some switches require both a prefix code and a suffix code. W hen the...
Page 245
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-77 Message Indicator Parameters Message Indicator Supervised This parameter determines whether the messaging system performs call progress for message indicator requests to the switch. When/How to Use This parameter is set when the Integrator utility is run. Some switches require the system to wait for a confirmation tone to indicate the switch accepted the message indicator event before returning to the...
Page 246
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-78 Min — Max — Default No Requires Restart No Switch-Dependent Yes Set by Integrator Yes Message Indicator Parameters Message Indicator Dials Number On Hook This parameter determines whether the phone system remains on hook when the messaging system sends the string for message indicator events. When/How to Use This parameter is set when the Integrator utility is run for messaging systems...
Page 247
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-79 If Set Too High Setting this parameter higher should not adversely affect system operation, although you should not modify it without talking to a technical support representative. If Set Too Low If this parameter is set too low, the system may not catch the whole string, and integration may fail. Min 0 Max 32 Default 0 Requires Restart No Switch-Dependent Yes Set by Integrator Yes...
Page 248
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-80 Related Parameters/Features If the Total Number of Inband Digits is set to 0, this parameter is dimmed. If Set Too High Setting this parameter higher may cause initial callers into the system to hear silence before the main greeting is voiced. Do not modify this parameter without talking to a technical support representative. If Set Too Low If this parameter is set too low, the system may regularly...
Page 249
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-81 Min 0 Max 30000 Default 25 Requires Restart Yes Switch-Dependent Yes Set by Integrator Yes Inband Page 1 Parameters Activate Digit Grabber (DIGRAB) This parameter determines whether the messaging system logs incoming DTMF to the screen and to the PLUS.LOG file. When/How to Use Enable this parameter if you want to monitor the DTMF that the system receives during the initial inband window....
Page 250
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-82 Related Parameters/Features You must set DTONDET at least 4 seconds higher than DTONW AIT, unless DTONDET is set to 0. For example, if you set DTONW AIT to 300, DTONDET must be set to at least 700. If Set Too High A high setting causes excessive off hook time between calls. If Set Too Low Setting this parameter to 0 disables it, and the system does not detect dial tones. The result is excessive off...