13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-73
 
  Message Delivery Parameters
 
Number of
Seconds to Wait
before Message
Delivery  This parameter defines the number of seconds the messaging system waits
to voice the Message Notification phrase after a subscriber answers the
phone.
 
 When/How to Use For most systems, the default value should be sufficient. Some switches
require a few seconds, however, to establish a voice path after an extension
goes off...

Page 242

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-74
 
 If Set Too High If this parameter is set too high, switches send dial tone for a specified time
before they time out and stop sending it. If DTONW AIT is set too high, the
switch timeout is exceeded and DTONW AIT is never completed.
Consequently, the outbound event is never initiated.
 
 If Set Too Low If DTONW AIT is set too low, and the switch does not send constant, stable
dial tone immediately, the...

Page 243

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-75
  Message Indicator Parameters
 
Message
Indicator Prefix
ON Code  This parameter specifies the code the messaging system must insert at the
beginning of the dialing string to turn on a message indicator.
 
 When/How to Use This parameter is set when the Integrator utility is run, if required by the
switch.
 
 Related Parameters/Features Some switches require both a prefix code and a suffix code. W hen...

Page 244

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-76
  Message Indicator Parameters
 
Message
Indicator Suffix
ON Code  This parameter specifies the code the messaging system must insert after the
extension number is dialed to turn on the Message Indicator.
 
 When/How to Use This parameter is set when the Integrator utility is run, if required by the
switch.
 
 Related Parameters/Features Some switches require both a prefix code and a suffix code. W hen the...

Page 245

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-77
  Message Indicator Parameters
 
Message
Indicator
Supervised  This parameter determines whether the messaging system performs call
progress for message indicator requests to the switch.
 
 When/How to Use This parameter is set when the Integrator utility is run. Some switches require
the system to wait for a confirmation tone to indicate the switch accepted the
message indicator event before returning to the...

Page 246

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-78
 
 Min
 —
 Max
 —
 Default
 No
 Requires Restart
 No
 Switch-Dependent
 Yes
 Set by Integrator
 Yes
 
  Message Indicator Parameters
 
Message
Indicator Dials
Number On Hook  This parameter determines whether the phone system remains on hook when
the messaging system sends the string for message indicator events.
 
 When/How to Use This parameter is set when the Integrator utility is run for messaging systems...

Page 247

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-79
 
 If Set Too High Setting this parameter higher should not adversely affect system operation,
although you should not modify it without talking to a technical support
representative.
 
 If Set Too Low If this parameter is set too low, the system may not catch the whole string,
and integration may fail.
 
 Min
 0
 Max
 32
 Default
 0
 Requires Restart
 No
 Switch-Dependent
 Yes
 Set by Integrator
 Yes...

Page 248

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-80
 
 Related Parameters/Features If the Total Number of Inband Digits is set to 0, this parameter is dimmed.
 
 If Set Too High Setting this parameter higher may cause initial callers into the system to hear
silence before the main greeting is voiced. Do not modify this parameter
without talking to a technical support representative.
 
 If Set Too Low If this parameter is set too low, the system may regularly...

Page 249

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-81
 
 Min
 0
 Max
 30000
 Default
 25
 Requires Restart
 Yes
 Switch-Dependent
 Yes
 Set by Integrator
 Yes
 
  Inband Page 1 Parameters
 
Activate Digit
Grabber
(DIGRAB)  This parameter determines whether the messaging system logs incoming
DTMF to the screen and to the PLUS.LOG file.
 
 When/How to Use Enable this parameter if you want to monitor the DTMF that the system
receives during the initial inband window....

Page 250

13. Setting Up the System
Implementation and Service Manual  System Setup Parameters List13-82
 
 Related Parameters/Features You must set DTONDET at least 4 seconds higher than DTONW AIT, unless
DTONDET is set to 0. For example, if you set DTONW AIT to 300, DTONDET
must be set to at least 700.
 
 If Set Too High A high setting causes excessive off hook time between calls.
 
 If Set Too Low Setting this parameter to 0 disables it, and the system does not detect dial
tones. The result is excessive off...