Page 221
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-53 Related Parameters/Features W hen the caller is first transferred to the second queue position or higher, the system voices , “Please hold, someone will be w ith you shortly,” and, “That extension is busy,” followed by, “You are number in the queue,” if these phrases are enabled. Afterwards, the system only voices the keypress options phrase, any additional call queuing phrases, and the caller’s position...
Page 222
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-54 See Preinstallation Configuration Worksheet Call Queuing Prompts Sheet (Call Queuing Setup Options) Call Queuing Parameters Custom Call Queuing Phrase for Operator This parameter determines whether the system uses a custom call queuing phrase for callers holding for the default operator mailbox. This phrase should be recorded as phrase 93 in the ENGLISH2.O32 voice file using V-Edit. When/How to...
Page 223
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-55 Min — Max — Default No Requires Restart No Switch-Dependent No Set by Integrator No See Preinstallation Configuration Worksheet Call Queuing Prompts Sheet (Call Queuing Setup Options) Call Queuing Parameters Number of Seconds for First Caller in Queue to Wait This parameter specifies the number of seconds the messaging system waits after attempting to transfer the first caller in a...
Page 224
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-56 Min 0 Max 15 Default Blank Requires Restart Yes Switch-Dependent Yes Set by Integrator Yes Intercom Paging Parameters Release Code for Intercom Paging This parameter specifies the code the system dials when required by the switch to return to a call after the system attempts to page the subscriber. When/How to Use This parameter is set when the Integrator is run, if required by the...
Page 225
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-57 Intercom Paging Parameters Number of Retries when Paging is Busy This parameter specifies the number of times the system attempts to page the subscriber when the paging extensions are busy. When/How to Use For most systems, the default value is sufficient. If the system experiences heavy traffic, increase this value. Related Parameters/Features None. If Set Too High The higher the setting, the...
Page 226
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-58 Intercom Paging Parameters Paging Wait Time (Intercom Redirect) This parameter specifies the number of seconds the messaging system waits for a subscriber to respond to a page before prompting the caller try another extension, to leave a message, to page the subscriber, or to disconnect. Note that the system prompts callers to try the page again only if the Maximum Number of Retries in Paging (Intercom...
Page 227
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-59 Related Parameters/Features The system looks for a Transfer Prefix Code only if no Custom Transfer Code is defined. If Set Too High Not applicable. If Set Too Low Not applicable. Min 0 Max 15 Default Blank Requires Restart No Switch-Dependent Yes Set by Integrator No Call Transfer Parameters Custom Transfer Code This parameter defines the series of commands required by the switch...
Page 228
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-60 because DTONW AIT determines the amount of continuous energy the messaging system must detect to recognize it as dial tone. C (followed by a number) Indicates that the system is to send a special feature code to the switch. The C is always followed by a number that defines how many characters are in the special feature code. For example, if 550 is the special feature code to activate intercom paging, a C3...
Page 229
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-61 If Set Too High Increasing this parameter should not adversely affect messaging system performance. However, the higher you set this parameter, the longer the caller waits to be transferred. If Set Too Low On some switches, a slight delay may be required. Min 0 Max 9 Default 0 Requires Restart No Switch-Dependent Yes Set by Integrator No Call Transfer Parameters Transfer Release Code...
Page 230
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-62 If Set Too High Not applicable. If Set Too Low Not applicable. Min 0 Max 15 Default &, Requires Restart No Switch-Dependent Yes Set by Integrator Yes Call Transfer Parameters Permit Voice Mail After a Busy or No Answer This parameter determines if callers can leave a voice-mail message for a subscriber whose extension is busy or unanswered. If you disable this parameter, callers are...