Page 171
13. Setting Up the System Implementation and Service Manual Searc hing f or a Partic ular Sys tem Setup Parameter13-3 Searching for a Particular System Setup Parameter If you are not sure what tab a certain parameter is located on, you can search for the parameter by the parameter name. To locate a specific System Setup parameter: 1. From the Search menu in System Setup, select Find. The Find First dialog box displays. 2. In the Text to find field, enter the name, or part of the name, of the...
Page 172
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-4 System Setup Parameters List System Setup is comprised of 26 tabs that contain parameters grouped by a specific feature or function, such as Operator parameters and Networking parameters. To access a particular feature’s parameters, click the corresponding tab. The following list references each System Setup parameter by tab and page number. General Parameters (Tab 1 of 26)...
Page 173
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-5 Initial Password for New Mailboxes - None Required..........................................13-29 Initial Password for New Mailboxes - Set to Default ............................................13-29 Initial Password for New Mailboxes - Random Generator Method.......................13-30 Caller Parameters (Tab 7 of 26) .............................................................................13-30 Permit...
Page 174
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-6 Intercom Paging Parameters (Tab 13 of 26) .........................................................13-55 Intercom Paging Code ........................................................................................13-55 Release Code for Intercom Paging.....................................................................13-56 Repeat Intercom Paging...
Page 175
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-7 Seconds to W ait for DID (DIDTIME)....................................................................13-79 Number of Milliseconds to W ait for Digits............................................................13-80 Off Hook Delay Time (OFFHDLY).......................................................................13-80 Activ ate Digit Grabber...
Page 176
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-8 General Parameters (Page 1 of 26) The General parameters control general system-lev el functions. General Parameters Enable Automated AttendantThe Automated Attendant routes calls to messaging system extensions. W hen the Automated Attendant is disabled, the messaging system routes callers directly to the subscribers’ mailboxes. It does not attempt to transfer calls to subscriber extensions. Note that this...
Page 177
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-9 General Parameters Number of Digits in a Mailbox This parameter determines the length and available range of subscriber mailboxes. For example, if you set this parameter to 5, the range of available mailboxes is 10000 to 99999. When/How to Use You must set this parameter using the System Setup before you begin creating subscriber mailboxes. If you change the value of this parameter after you have created...
Page 178
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-10 If Set Too Low A low setting for this parameter does not affect messaging system performance. Setting it to 0 would disable the parameter and is not recommended. Min 0 Max 99 Default 5 Requires Restart No Switch-Dependent No Set by Integrator No General Parameters Tutor for New Mailboxes This parameter determines whether Call Educator, the messaging system tutorial, is enabled for...
Page 179
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-11 General Parameters Shutdown System After Daily Maintenance This parameter determines whether the messaging system goes through an automatic shutdown after daily maintenance is complete. After the system shutdown is complete, the user-supplied third-party utilities specified in the RUNVM.CMD file execute and the messaging system restarts. When/How to Use Enable this parameter if you want to run...
Page 180
13. Setting Up the System Implementation and Service Manual System Setup Parameters List13-12 If Set Too Low Not applicable. Min — Max — Default No Requires Restart No Switch-Dependent No Set by Integrator No General Parameters First Personal Group List Number This parameter determines the first number and defines the range for the 10 personal group lists available to each subscriber mailbox. When/How to Use The First Personal Group List Number must be at least 10 less than...