Page 151

10. Establishing a Serial Integration
Implementation and Service Manual  Supporting Multiple-Prefix Centrex Systems10-11
11.  To exit the editor, click the icon in the upper-left corner of the window and select
Close.
12.  To close the OS/2 window, type EXIT 
and press .
13.  To load the file, shut down OS/2 and restart the PC.
Example SMDI.PFX File
The following sample file illustrates how you can set up the SMDI.PFX for a system
using a 10-digit Centrex application. In the sample, the system has three...

Page 152

10. Establishing a Serial Integration
Implementation and Service Manual  Supporting Multiple-Prefix Centrex Systems10-12
Notes: 

Page 153

Implementation and Service Manual  Integrating with an Uninterruptible Power Supply11-1
CHAPTER 11
Integrating with an Uninterruptible Power Supply
During a power failure, the messaging system files and the PC can be sev erely
damaged. Attaching an Uninterruptible Power Supply (UPS) prov ides protection against
failures of a relativ ely short duration. Note, howev er, if there is a major power failure that
exceeds the life of the UPS’s battery, the PC can lose power and the messaging system
and PC can be...

Page 154

11. Integrating with an Uninterruptible Power Supply
Implementation and Service Manual  Understanding How UPS Integration W orks11-2
 Understanding How UPS Integration Works
  Most UPSs hav e three states of operation:
· Normal Operation – The UPS is receiving power from the local utilities
company through the electrical outlet.
· Power Out – The UPS is not receiving power from the local utilities company,
and the UPS is supplying power to the PC.
· Low Battery – The UPS is still supplying power to the...

Page 155

11. Integrating with an Uninterruptible Power Supply
Implementation and Service Manual  Running the UPS Integrator Utility11-3
  There are two ways to av oid this file-sharing problem:
-  Run the Serial Integration utility before running the UPS Integration
utility.
-  If you need to run the Serial Integration utility after the UPS integration
has been run, close the UPS Monitor before running the Serial
Integration utility. To do this, click the UPS icon once and select Close.
After Serial Integration...

Page 156

11. Integrating with an Uninterruptible Power Supply
Implementation and Service Manual  Running the UPS Integrator Utility11-4
To run the UPS Integrator utility immediately following messaging system
installation:
1.  During messaging system installation, select UPS from the Installation Setup utility
dialog box. The UPS Integrator dialog box displays.
2.  From the Options menu, select Setup. The UPS Setup dialog box displays.
If the Power out and Low batter fields match the entries on the following...

Page 157

11. Integrating with an Uninterruptible Power Supply
Implementation and Service Manual  Running the UPS Integrator Utility11-5
  If you do not know the masks for the UPS, click Learn to start the Learn mode, which
enables the UPS monitor to establish the UPS signals. The system displays the
message, “Begin Learn Mode.” You can select Cancel at any time to abort the Learn
process.
6.  The system displays a message prompting you to v erify that the cable from the UPS
to the serial port is securely...

Page 158

11. Integrating with an Uninterruptible Power Supply
Implementation and Service Manual  Running UPS Integration After Messaging System Installation11-6
Running UPS Integration After Messaging System Installation
Although it is recommended that you run UPS Integration during messaging system
installation, you can run it at any time.
By default, the UPS Integrator only learns the normal and power out states and interprets
any mask (an 8-digit binary image that represents the state of operation) that is...

Page 159

11. Integrating with an Uninterruptible Power Supply
Implementation and Service Manual  Running UPS Integration After Messaging System Installation11-7
4.  If you do not want the system to attempt to learn the UPS’s low-battery state and you
do not want to change the pin-signaling default, proceed with the step 5. If you do
want the system to attempt to learn the UPS’s low-battery state or you do want to
change the pin-signaling default, complete the following:
a.  Click Adv anced. The Adv anced Settings...

Page 160

11. Integrating with an Uninterruptible Power Supply
Implementation and Service Manual  Running UPS Integration After Messaging System Installation11-8
9. After the system learns the necessary states, the message “Reconnect power to
UPS” displays. Reconnect the UPS power cord to the electrical outlet, then click OK.
A dialog box displays the message “End Learn Mode.”
  After Learn mode is complete or you manually enter the UPS’s masks, the system
constantly monitors the current mask and compares it to...