10. Establishing a Serial Integration Implementation and Service Manual Supporting Multiple-Prefix Centrex Systems10-11 11. To exit the editor, click the icon in the upper-left corner of the window and select Close. 12. To close the OS/2 window, type EXIT and press . 13. To load the file, shut down OS/2 and restart the PC. Example SMDI.PFX File The following sample file illustrates how you can set up the SMDI.PFX for a system using a 10-digit Centrex application. In the sample, the system has three...
Page 152
10. Establishing a Serial Integration Implementation and Service Manual Supporting Multiple-Prefix Centrex Systems10-12 Notes:
Page 153
Implementation and Service Manual Integrating with an Uninterruptible Power Supply11-1 CHAPTER 11 Integrating with an Uninterruptible Power Supply During a power failure, the messaging system files and the PC can be sev erely damaged. Attaching an Uninterruptible Power Supply (UPS) prov ides protection against failures of a relativ ely short duration. Note, howev er, if there is a major power failure that exceeds the life of the UPS’s battery, the PC can lose power and the messaging system and PC can be...
Page 154
11. Integrating with an Uninterruptible Power Supply Implementation and Service Manual Understanding How UPS Integration W orks11-2 Understanding How UPS Integration Works Most UPSs hav e three states of operation: · Normal Operation – The UPS is receiving power from the local utilities company through the electrical outlet. · Power Out – The UPS is not receiving power from the local utilities company, and the UPS is supplying power to the PC. · Low Battery – The UPS is still supplying power to the...
Page 155
11. Integrating with an Uninterruptible Power Supply Implementation and Service Manual Running the UPS Integrator Utility11-3 There are two ways to av oid this file-sharing problem: - Run the Serial Integration utility before running the UPS Integration utility. - If you need to run the Serial Integration utility after the UPS integration has been run, close the UPS Monitor before running the Serial Integration utility. To do this, click the UPS icon once and select Close. After Serial Integration...
Page 156
11. Integrating with an Uninterruptible Power Supply Implementation and Service Manual Running the UPS Integrator Utility11-4 To run the UPS Integrator utility immediately following messaging system installation: 1. During messaging system installation, select UPS from the Installation Setup utility dialog box. The UPS Integrator dialog box displays. 2. From the Options menu, select Setup. The UPS Setup dialog box displays. If the Power out and Low batter fields match the entries on the following...
Page 157
11. Integrating with an Uninterruptible Power Supply Implementation and Service Manual Running the UPS Integrator Utility11-5 If you do not know the masks for the UPS, click Learn to start the Learn mode, which enables the UPS monitor to establish the UPS signals. The system displays the message, “Begin Learn Mode.” You can select Cancel at any time to abort the Learn process. 6. The system displays a message prompting you to v erify that the cable from the UPS to the serial port is securely...
Page 158
11. Integrating with an Uninterruptible Power Supply Implementation and Service Manual Running UPS Integration After Messaging System Installation11-6 Running UPS Integration After Messaging System Installation Although it is recommended that you run UPS Integration during messaging system installation, you can run it at any time. By default, the UPS Integrator only learns the normal and power out states and interprets any mask (an 8-digit binary image that represents the state of operation) that is...
Page 159
11. Integrating with an Uninterruptible Power Supply Implementation and Service Manual Running UPS Integration After Messaging System Installation11-7 4. If you do not want the system to attempt to learn the UPS’s low-battery state and you do not want to change the pin-signaling default, proceed with the step 5. If you do want the system to attempt to learn the UPS’s low-battery state or you do want to change the pin-signaling default, complete the following: a. Click Adv anced. The Adv anced Settings...
Page 160
11. Integrating with an Uninterruptible Power Supply Implementation and Service Manual Running UPS Integration After Messaging System Installation11-8 9. After the system learns the necessary states, the message “Reconnect power to UPS” displays. Reconnect the UPS power cord to the electrical outlet, then click OK. A dialog box displays the message “End Learn Mode.” After Learn mode is complete or you manually enter the UPS’s masks, the system constantly monitors the current mask and compares it to...