Page 111
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-11 To delete settings for an existing Dialogic D/42D-SL or D/42D-SX board: 1. If the messaging system is running, select Exit from the File menu to shut it down. 2. Double-click the Configure icon in the program folder. The Configure dialog box displays. 3. Under Installable Hardware, select Dialogic D4xD, then click Configure. The Configure – Dialogic D4xD dialog box...
Page 112
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-12 10. Restart the PC: a. Click the right mouse button on an empty area of the OS/2 desktop and select Shut down from the menu that displays. b. W hen you are prompted whether you want to close all windows and activ e programs, click OK. c. When prompted to shut down or reboot, press to restart the PC. To verify the SET_UP.CFG file is set up correctly for the D/42D-SL or...
Page 113
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-13 Specifying Settings for the Dialogic D/42D-NS Boards Use the following procedures to add, modify, or delete settings for Dialogic D/42D-NS boards. W hen using digital boards, you must also v erify two SET_UP.CFG file parameters if the system is configured for OctelNet or AMIS. To specify settings for a new Dialogic D/42D-NS board: 1. During installation, select Configure...
Page 114
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-14 4. To identify the extensions assigned to each D/42D-NS port, click Voice Mail Port Numbering. The Configure – D42NS Voice Mail Port Numbers dialog box displays. 5. To specify the extension for port 1, enter the extension number in the corresponding field. 6. To identify the remaining extensions, either enter each extension number next to each port number or, if the...
Page 115
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-15 12. Repeat steps 9-11 for each additional D42D-NS board you installed. 13. To sav e the settings, click OK. The Configure dialog box displays. 14. To close Configure, click Exit. 15. Restart the PC: a. Click the right mouse button on an empty area of the OS/2 desktop and select Shut down from the menu that displays. b. W hen you are prompted whether you want to close...
Page 116
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-16 5. Under Shared Memory Addresses, select the address of the board you want to modify, then click Change. The Configure – Dialogic D4xD dialog box displays. 6. In the field under Dialogic Shared Memory Addresses, enter the board’s new shared memory address. The SW 1 diagram displays the proper jumper configuration for the Shared Memory Address you selected. The switch...
Page 117
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-17 To delete settings for an existing Dialogic D/42D-NS board: 1. If the messaging system is running, select Exit from the File menu to shut it down. 2. Double-click the Configure icon in the program folder. The Configure dialog box displays. 3. Under Installable Hardware, select Dialogic D4xD, then click Configure. The Configure – Dialogic D4xD dialog box displays. 4....
Page 118
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-18 10. Restart the PC: a. Click the right mouse button on an empty area of the OS/2 desktop and select Shut down from the menu that displays. b. W hen you are prompted whether you want to close all windows and activ e programs, click OK. c. When prompted to shut down or reboot, press to restart the PC. To verify the SET_UP.CFG file is set up correctly for the D/42D-NS...
Page 119
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Brooktrout TruFax Board Settings7-19 Specifying Brooktrout TruFax Board Settings Use the following procedure to specify Brooktrout TruFax board. To specify Brooktrout TruFax board settings: 1. During installation, select Configure from the Installation Setup Utility dialog box. The Configure dialog box displays. If the messaging system is already installed, you can launch Configure any time by...
Page 120
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Brooktrout TruFax Board Settings7-20 5. Click TruFax IRQ – Port Address settings. The Brooktrout TruFax Interrupt – Port Address Settings dialog box displays. 6. In the Hardware Interrupt field, enter the hardware interrupt you recorded when you configured the boards. The accompanying diagram displays the proper jumper configuration for the interrupt you selected. If the board does not load properly...