Page 71

5. Preparing the Hardware
Implementation and Service ManualInstalling the Tape Backup Unit (Optional)5-29
 
27.  Leave the values for DMA, Interrupt, and Base Address at the defaults. Under
Transfer speed, click 500k.
28.  Click the Unattended tab to advance to the Unattended page.
 
29.  Verify that the Enable Unattended box is unchecked, then click the Errors tab to
advance to the Errors page.
 
30.  Leave the values for Error retry count, Locked retry count, and Logfile size values at
the defaults....

Page 72

5. Preparing the Hardware
Implementation and Service ManualInstalling the Tape Backup Unit (Optional)5-30
To select files for backup:
1.  Access the BackMaster main window, if it is not currently displayed.
2.  From the Backup menu, choose Selective.
3.  In the Drives field, select the letter of the drive(s) containing messaging system files.
Click OK. The Selection Window displays.
4.  Click the + sign to display the subdirectories on the root drive you selected.
5.  Select the subdirectories you want...

Page 73

5. Preparing the Hardware
Implementation and Service ManualInstalling the Tape Backup Unit (Optional)5-31
11.  In the Save as filename field, type TAPE.FSS.
12. Click OK.
13.  If you want to run a manual backup at this time, select Start backup from the Backup
pull-down menu. If you do not want to run a backup now, select Cancel backup from
the Backup pull-down menu, then click Yes.
14.  To close the BackMaster program, double-click the icon in the top left corner of the
BackMaster main window.
15.  To...

Page 74

5. Preparing the Hardware
Implementation and Service ManualInstalling the Tape Backup Unit (Optional)5-32
backup. For information on verifying the files backed up onto the tape drive, refer to
the 
BackMaster User Reference Manual.
To indicate the day(s) to run automatic tape backup:
1.  At the BACKMAST directory prompt, change to the root directory by typing CD..
and pressing . To change to the CVR directory, type CD CVR then press
.
2.  To edit the RUNVM.CMD file, type E RUNVM.CMD and press .
3....

Page 75

5. Preparing the Hardware
Implementation and Service ManualInstalling a Printer (Optional)5-33
Be advised that if a tape is not inserted into the tape backup drive, or if the tape that is
inserted is not operational (is a “bad” tape), the automated attendant/voice mail system
will not restart as it should after the system shuts down to perform daily maintenance.
Installing a Printer (Optional)
If you are using a printer, install and test it using the instructions in the printer
documentation supplied by...

Page 76

5. Preparing the Hardware
Implementation and Service ManualInstalling a Printer (Optional)5-34
Notes: 

Page 77

Implementation and Service ManualInstalling the Software6-1
CHAPTER 6
Installing the Software
On new turnkey systems, the messaging system is deliv ered with both OS/2 and the
messaging system software installed. Consequently, you may not need to complete
some of the OS/2 and messaging system software installation steps detailed in this
chapter. You should, howev er, run certain utilities to set up the messaging system to
work with the phone switch. Step-by-step procedures on running each system utility...

Page 78

6. Installing the Software
Implementation and Service ManualPreparing the PC f or Sys tem Ins tallation6-2
Procedures in this chapter assume that the hard driv e on which the system is installed is
driv e C, that an additional hard driv e that may be installed is D, that the disk driv e is A,
and that the CD-ROM driv e, if installed, is F. Driv e designations on the specific PC on
which you are working may v ary. Confirm the appropriate driv e letters, when necessary,
in procedures prov ided in this...

Page 79

6. Installing the Software
Implementation and Service ManualInstalling OS/2 W arp 4.06-3
8.  If you are not installing to the C drive, highlight the Specify a different drive option,
press , follow the onscreen prompts to specify the drive to which you want
to install Warp, then continue with step 9.
If you are installing to a new or unpartitioned hard driv e:
The following procedure supports hard drives up to 12.1 GB. If you have a larger
hard drive, contact a technical support representative.
a....

Page 80

6. Installing the Software
Implementation and Service ManualInstalling OS/2 W arp 4.06-4
r.  To accept the default, which is the amount of remaining space, press .
The Type of Partition box displays.
s.  Select Extended Logical Driv e and press . The FDISK screen
displays.
t.  Press . The Exit FDISK box displays. Select Sav e and Exit then press
.
u.  Remov e disk 1, reinsert the IBM W arp Version 4 Installation disk, and press
. The PC reboots and restarts the installation.
v .  Repeat steps 2 through...