Page 101
Implementation and Service Manual Setting Up the System to Recognize Voice and Fax Boards7-1 CHAPTER 7 Setting Up the System to Recognize Voice and Fax Boards The steps prov ided in this chapter will help you use the Configure utility to specify the interrupts and addresses of the v oice and fax boards you installed in the messaging system. These settings determine the v oice and fax driv er and firmware command lines used in the CONFIG.SYS file. The correct interrupts and addresses must be specified in...
Page 102
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-2 Specifying Dialogic Board Settings The procedure you use to specify Dialogic board settings depends on the type of Dialogic boards you installed in the system: · D/41D board · DIALOG/4 board · D/42D-SL and D/42D-SX board · D/42D-NS board Specifying Settings for Dialogic DIALOG/4 and D/41D Boards Use the following procedures to specify, modify, or delete settings for Dialogic...
Page 103
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-3 2. Under Installable Hardware, select Dialogic D4xD, then click Configure. The Configure – Dialogic D4xD dialog box displays. 3. Under Voice Board Type, select the D41D option. 4. In the Hardware Interrupt field, enter the hardware interrupt you recorded when you configured the boards. The Jumper Block JP1 diagram displays the proper jumper configuration for the...
Page 104
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-4 10. To close Configure, click Exit. 11. Restart the PC: a. Click the right mouse button on an empty area of the OS/2 desktop and select Shut down from the menu that displays. b. W hen you are prompted whether you want to close all windows and activ e programs, click OK. c. When prompted to shut down or reboot, press to restart the PC. To modify settings for an existing...
Page 105
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-5 5. Under Shared Memory Address, select the address of the board you want to modify, then click Change. The Configure – Dialogic D4xD dialog box displays. 6. In the field under Dialogic Shared Memory Addresses, enter the board’s new shared memory address. The SW 1 diagram displays the proper jumper configuration for the Shared Memory Address you selected. The switch...
Page 106
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-6 To delete settings for an existing Dialogic DIALOG/4 or D/41D board: 1. If the messaging system is running, select Exit from the File menu to shut it down. 2. Double-click the Configure icon in the program folder. The Configure dialog box displays. 3. Under Installable Hardware, select Dialogic D4xD, then click Configure. The Configure – Dialogic D4xD dialog box...
Page 107
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-7 10. Restart the PC: a. Click the right mouse button on an empty area of the OS/2 desktop and select Shut down from the menu that displays. b. W hen you are prompted whether you want to close all windows and activ e programs, click OK. c. When prompted to shut down or reboot, press to restart the PC. Specifying Settings for Dialogic D/42D-SL and D/42D-SX Boards Use the...
Page 108
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-8 2. Under Installable Hardware, select Dialogic D4xD, then click Configure. The Configure – Dialogic D4xD dialog box displays. 3. Under Voice Board Type, select the D/42DSL or D/42DSX option as it applies to the board. 4. In the Hardware Interrupt field, enter the hardware interrupt you recorded when you configured the boards. The Jumper Block JP1 diagram displays the...
Page 109
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-9 10. To close Configure, click Exit. 11. Restart the PC: a. Click the right mouse button on an empty area of the OS/2 desktop and select Shut down from the menu that displays. b. W hen you are prompted whether you want to close all windows and activ e programs, click OK. c. When prompted to shut down or reboot, press to restart the PC. To modify settings for an existing...
Page 110
7. Setting Up the System to Recognize Voice and Fax Boards Implementation and Service Manual Specifying Dialogic Board Settings7-10 5. Under Shared Memory Addresses, select the address of the board you want to modify, then click Change. The Configure – Dialogic D4xD dialog box displays. 6. In the field under Dialogic Shared Memory Addresses, enter the board’s new shared memory address. The SW 1 diagram displays the proper jumper configuration for the Shared Memory Address you selected. The switch...