Page 101

Implementation and Service Manual Setting Up the System to Recognize Voice and Fax Boards7-1
CHAPTER 7
Setting Up the System to Recognize Voice and Fax Boards
The steps prov ided in this chapter will help you use the Configure utility to specify the
interrupts and addresses of the v oice and fax boards you installed in the messaging
system. These settings determine the v oice and fax driv er and firmware command lines
used in the CONFIG.SYS file. The correct interrupts and addresses must be specified in...

Page 102

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-2
Specifying Dialogic Board Settings
The procedure you use to specify Dialogic board settings depends on the type of
Dialogic boards you installed in the system:
· D/41D board
· DIALOG/4 board
·  D/42D-SL and D/42D-SX board
· D/42D-NS board
Specifying Settings for Dialogic DIALOG/4 and D/41D Boards
Use the following procedures to specify, modify, or delete settings for Dialogic...

Page 103

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-3
2.  Under Installable Hardware, select Dialogic D4xD, then click Configure. The
Configure – Dialogic D4xD dialog box displays.
 
3.  Under Voice Board Type, select the D41D option.
4.  In the Hardware Interrupt field, enter the hardware interrupt you recorded when you
configured the boards. The Jumper Block JP1 diagram displays the proper jumper
configuration for the...

Page 104

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-4
10.  To close Configure, click Exit.
11.  Restart the PC:
a.  Click the right mouse button on an empty area of the OS/2 desktop and select
Shut down from the menu that displays.
b.  W hen you are prompted whether you want to close all windows and activ e
programs, click OK.
c.  When prompted to shut down or reboot, press  to restart the
PC.
To modify settings for an existing...

Page 105

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-5
5.  Under Shared Memory Address, select the address of the board you want to modify,
then click Change. The Configure – Dialogic D4xD dialog box displays.
 
6.  In the field under Dialogic Shared Memory Addresses, enter the board’s new shared
memory address. The SW 1 diagram displays the proper jumper configuration for the
Shared Memory Address you selected. The switch...

Page 106

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-6
To delete settings for an existing Dialogic DIALOG/4 or D/41D board:
1.  If the messaging system is running, select Exit from the File menu to shut it down.
2.  Double-click the Configure icon in the program folder. The Configure dialog box
displays.
 
3.  Under Installable Hardware, select Dialogic D4xD, then click Configure. The
Configure – Dialogic D4xD dialog box...

Page 107

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-7
10.  Restart the PC:
a.  Click the right mouse button on an empty area of the OS/2 desktop and select
Shut down from the menu that displays.
b.  W hen you are prompted whether you want to close all windows and activ e
programs, click OK.
c.  When prompted to shut down or reboot, press  to restart the
PC.
Specifying Settings for Dialogic D/42D-SL and D/42D-SX Boards
Use the...

Page 108

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-8
2.  Under Installable Hardware, select Dialogic D4xD, then click Configure. The
Configure – Dialogic D4xD dialog box displays.
 
3.  Under Voice Board Type, select the D/42DSL or D/42DSX option as it applies to the
board.
4.  In the Hardware Interrupt field, enter the hardware interrupt you recorded when you
configured the boards. The Jumper Block JP1 diagram displays the...

Page 109

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-9
10.  To close Configure, click Exit.
11.  Restart the PC:
a.  Click the right mouse button on an empty area of the OS/2 desktop and select
Shut down from the menu that displays.
b.  W hen you are prompted whether you want to close all windows and activ e
programs, click OK.
c.  When prompted to shut down or reboot, press  to restart the
PC.
To modify settings for an existing...

Page 110

7. Setting Up the System to Recognize Voice and Fax Boards
Implementation and Service Manual Specifying Dialogic Board Settings7-10
5.  Under Shared Memory Addresses, select the address of the board you want to
modify, then click Change. The Configure – Dialogic D4xD dialog box displays.
 
6.  In the field under Dialogic Shared Memory Addresses, enter the board’s new shared
memory address. The SW 1 diagram displays the proper jumper configuration for the
Shared Memory Address you selected. The switch...