Page 41
4. Understanding the Installation Process Implementation and Service Manual Installation Methodology Steps4-3 Installation Step Purpose and Importance Run the System Setup utilityThe System Setup utility configures the system. For information on running the System Setup utility, see Chapter 13, “Setting Up the System .” Install the Visual Mailbox module (optional)The Visual Mailbox software is preinstalled on most systems. However, there are additional steps you must perform to complete Visual Mailbox...
Page 42
4. Understanding the Installation Process Implementation and Service Manual Installation Methodology Steps4-2 Notes:
Page 43
Implementation and Service ManualPreparing the Hardware5-1 CHAPTER 5 Preparing the Hardware In almost all cases, the messaging system is deliv ered with all necessary v oice and fax boards installed. Consequently, you may not need to complete certain hardware configuration and installation steps detailed in this chapter. You should, howev er, connect the phone and fax lines to the messaging system and install certain additional hardware components, such as the uninterruptible power supply (UPS). If you...
Page 44
5. Preparing the Hardware Implementation and Service ManualAssembling Materials5-2 Assembling Materials Before you begin hardware installation, assemble the materials you are required to use. The materials are listed on the Installation Checklist prov ided with the messaging system. Some of the equipment listed, such as a tape backup dev ice, is optional and therefore not required for the messaging system. Verifying Phone System Readiness Before beginning hardware installation, you must make...
Page 45
5. Preparing the Hardware Implementation and Service ManualConfiguring the Voice Boards5-3 Configuring the Voice Boards Voice boards prov ide the interface between the messaging system and the phone system that allows them to communicate. You must configure the jumpers and switch settings on the Dialogic v oice boards before you install them. Note that after you install the messaging system, you must also configure the software to recognize the v oice boards. Voice boards contain ports, which are...
Page 46
5. Preparing the Hardware Implementation and Service ManualConfiguring the Voice Boards5-4 The following diagram illustrates the DIALOG/4 board. The following diagram illustrates the D/4xD board. The location of the relev ant jumpers and switches on the D/42D-SX and D/42D-SL boards are approximately the same as on the D/4xD board. The following diagram illustrates the D/42D-NS board. Complete the following steps, as required, to configure each Dialogic board: 1. Set the board’s base shared memory...
Page 47
5. Preparing the Hardware Implementation and Service ManualConfiguring the Voice Boards5-5 Setting the board’s base shared memory address – The base shared memory address allows the v oice board to communicate with the v oice driv er and, in turn, the messaging system. SW 1 determines the Dialogic board’s base shared memory address. If you are only installing one Dialogic board, leav e SW 1 at the default setting unless it conflicts with another component. If you are installing multiple boards or if...
Page 48
5. Preparing the Hardware Implementation and Service ManualConfiguring the Fax Boards5-6 Do not change the settings of either of these jumpers unless a technical support representativ e directs you to set the v oice board to an address using an alternate segment. Setting the board’s hardware interrupt – The JP1 jumper block sets the Dialogic board hardware interrupt lev el, also called the IRQ. Interrupt settings for these boards range from 2 through 7. Install the jumper that corresponds to the...
Page 49
5. Preparing the Hardware Implementation and Service ManualConfiguring the Fax Boards5-7 Configuring the Brooktrout TruFax Board The TruFax is a 2-port fax board supported for use with the messaging system. In the board drawing, the black square in the switch settings indicates the jumper position. Use caution when handling fax boards as they are electrostatic-sensitiv e. Make sure you ground the PC, the work area, and the ground end of the antistatic wrist strap prior to handling a board, and always...
Page 50
5. Preparing the Hardware Implementation and Service ManualIns talling the Voic e and Fax Boards5-8 The system searches addresses 140 through 280 to determine if fax boards are present. Because the system considers any board found in this range of addresses a fax board, do not set other boards, such as a network interface card (NIC), to addresses within this range. Record the port address for each TruFax board you configure; you will need to refer to it when you run the Configure utility. Setting the...