Page 331
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-69 Add IP Interface Assembly 6 11. Typ e d omain name in the Domain field . 12. If using DNS, c lic k Add under the DNS Service Search Order field and type its IP ad d ress. 13. Clic k on the WINS Ad dress tab .
Page 332
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-70 Add IP Interface Assembly 6 14. Make sure the [ 2] DEC shows in the Adapter field. 15. If WINS server is availab le, typ e its IP ad d ress in the Primary WINS Server field . 16. If DNS is availab le, selec t Enable DNS for Windows Resolution . 17. If the network uses an imp orted LMHOSTS file, selec t Enable LMHOSTS Lookup and Import...
Page 333
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-71 Add IP Interface Assembly 6 If administered remotely throug h p c ANYWHERE: 21. Clic k on the p c ANYWHERE Restart Host Comp uter b utton on the toolb ar to restart the c omputer. If administered loc ally on a monitor, keyb oard, and mouse: 21. Clic k Ye s in the d ialog b ox to restart the c omp uter. !WARNING: When c onnec ted remotely...
Page 334
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-72 Add IP Interface Assembly 6 3. At the c ommand p romp t, type ping nnn.nnn.nnn.nnn (whic h is the IP ad d ress of your g ateway). nIf everything is c onfigured c orrec tly, the system respond s with the following message: Reply from nnn.nnn.nnn.nnn: bytes=32 time Settings > Control Panel > Network . Selec t the Adapters tab and hig...
Page 335
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-73 Add IP Interface Assembly 6 3. At the c ommand p romp t, typ e ping 192.11.13.8 (whic h is the IP ad d ress of the internal p roc essor). nIf you have c onnec tivity, the system respond s with the following messag e: Reply from 192.11.13.8: bytes=32 time
Page 336
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-74 Add IP Interface Assembly 6 Connect the Monitor, Keyboard, and Mouse 1. Attac h a VGA monitor to the VGA c onnec tor of the TN802 IP Interfac e external c ab le assemb ly. 2. Attac h the keyb oard to the KEYBOARD c onnec tor of the external c ab le assemb ly. 3. Attach the mouse to the MOUSE connector of the external c able assemb ly. 4. Plug...
Page 337
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-75 Add IP Interface Assembly 6 5. When d one, c lic k OK, OK .
Page 338
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-76 Add IP Interface Assembly 6 Upgrade to TN802B (R8) NOTE: The upg rad e takes ab out 20 minutes. 1. Insert the flash d isk into the rig ht most slot on the TN802 IP trunk. On the monitor, a d ialog b ox assig ns a d rive letter with the removab le med ia d esig nation; the d efault is D:. 2. Rig ht c lic k on Start > Explore to op en the Wind...
Page 339
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-77 Add IP Interface Assembly 6 10. Clic k Start > Shut Down and selec t Restart the computer? or on the TN802: Press the rec essed reset b utton on the fac ep late (see Figure 6-26 ) until the LCD shows a flashing MSHUT * . When the flashing stops and the asterisk d isap p ears (ab out 2 min), reseat the c irc uit p ac k to restart the...
Page 340
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-78 Add IP Interface Assembly 6 Circuit Pack Verification 1. Type change circuit-pack and p ress En te r. 2. Chec k the Cod e c olumn to see if it says DSMAPD or Med Pro. . 3. To c orrec t it, g o to the entry just above the TN802B that says DSMAPD. 4. Type MEDPRO, and press En t e r. Changing the one entry automatic ally c hang es the entry ab...