    							4.Select the paper path test options for the test you want to run
    5. Press the  OK button to begin the test, and then observe the control-panel designators (see the
    table below). The sensors should display a  1 status as paper passes by the sensors.
    Table 3-2   Paper-path sensors
    Sensor nameSensor
    numberReplacement part
    numberDescriptionPaper-path sensor test
    name
    TOP sensorPS215RM1-6511-000CNPhotointerrupterA TOP sensor
    Fuser delivery sensorPS2110 Volt:
    RM1-6274-000CN
    220 Volt:
    RM1-6319-000CNPhotointerrupterB Fuser output sensor
    Duplex media-feed sensorPS502RM1-6280-000CNPhotointerrupterC Duplex sensor
    Media width sensorPS225RM1-6512-000CNPhotointerrupterD Paper width sensor 1
    Paper feeder media-feed
    sensor - Tray 31PS8008CE530-69001PhotointerrupterE Tray 3 feed sensor
    Paper feeder media-feed
    sensor - Tray 41PS8008 CE530-69001 PhotointerrupterF Tray 4 feed sensor
    1Tray 3 and Tray 4 use a PS8008 sensor.
    Sensor test (interactive)
    Performs tests to determine whether the paper-path sensors are operating correctly.
    Table 3-3  MANUAL SENSOR TEST (special mode test)
    Sensor or switch
    nameSensor
    numberReplacement part
    numberDescriptionPaper-path sensor
    test nameTesting of sensor
    TOP sensorPS215RM1-6511-000CNPhotointerrupterA TOP sensorOpen the cartridge
    door, remove the
    print cartridge, raise
    the registration
    shutter, and then use
    a screwdriver to
    activate the sensor.
    Fuser delivery sensorPS2110 Volt:
    RM1-6274-000CN
    220 Volt:
    RM1-6319-000CNPhotointerrupterB Fuser output
    sensorOpen the rear door,
    and then use a
    screwdriver to
    activate the sensor.
    Duplex media-feed
    sensorPS502RM1-6280-000CN
    (power supply)PhotointerrupterC Duplex sensorRemove the Tray 2
    cassette, push the
    green button to drop
    the duplex tray, and
    then raise the tray.
    Media width sensor PS225 RM1-6512-000CN PCA D Paper width
    sensor 1 Open the cartridge
    door, remove the
    print cartridge, and
    then lift the
    registration flap to
    activate the sensor.
    ENWW
    Tools for troubleshooting 137 
    						
    							Sensor or switch
    nameSensor
    numberReplacement part
    numberDescriptionPaper-path sensor
    test nameTesting of sensor
    Paper feeder media-
    feed sensor - Tray 31PS8008(Replace feeder
    unit)PhotointerrupterE Tray 3 feed sensorRemove the Tray 2
    cassette, use a small
    screwdriver to
    activate the sensor
    through the small
    slot toward the front
    of the product.
    Paper feeder media-
    feed sensor - Tray 41PS8008(Replace feeder
    unit)PhotointerrupterF Tray 4 feed sensorRemove the Tray 3
    cassette, use a small
    screwdriver to
    activate the sensor
    through the small
    slot toward the front
    of the product.
    Face-down media
    tray media-full sensorPS4Photo interruptor:
    WG8-5696-000CN
    Top-cover flag:
    RM1-6289-000CNPhotointerrupterG FD tray full sensorLift the face-down
    tray output levers to
    activate the sensor.
    Rear cover open
    sensorPS1WG8-5696-000CNPhotointerrupterH Face-up detect
    sensorOpen the rear door
    to about 15 degrees.
    Cartridge-door
    switchSW501WC4-5171-000CNSwitchI Cartridge-door
    open switchOpen the cartridge
    door.
    Face-up detect
    sensorPS8001WG8-5696-000CNPhotointerrupterJ Rear cover open
    sensorOpen the rear door
    to about 90 degrees.
    MP tray media-
    presence sensorPS205RM1-6510-000CNPhotointerrupterK Tray 1 paper
    sensorPush the sensor
    lever to the right of
    the center of the tray,
    and hold it there for 3
    seconds.
    Cassette media-
    presence sensorPS3Currently not
    replaceablePhotointerrupterL Tray 2 paper
    sensorRemove the Tray 2
    cassette, and then
    push the sensor
    lever.
    Tray 2 cassette
    presence switchSW235 RM1-6487-000CN
    (tray sensor PCA) Switch M Tray 2 detect
    sensor Remove the Tray 2
    cassette, and then
    reinstall it.
    1Tray 3 and Tray 4 use a PS8008 sensor.
    Table 3-4
      MANUAL SENSOR TEST 2 (special mode test)
    Sensor or switch
    nameSensor
    numberReplacement part
    numberDescriptionPaper-path sensor
    test nameTesting of sensor
    Paper feeder Tray 3
    cassette media-
    presence sensor
    1
    PS451CE530-69001PhotointerrupterN Tray 3 paper
    sensorRemove the Tray 3
    cassette, and then
    push the sensor
    lever.
    Paper feeder Tray 3
    cassette presence
    sensor
    1
    PS461 CE530-69001 Photointerrupter O Tray 3 detect
    sensorRemove the Tray 3
    cassette, and then
    reinstall it.
    Table 3-3
      MANUAL SENSOR TEST (special mode test) (continued)
    138 Chapter 3   Solve problems ENWW 
    						
    							Sensor or switch
    nameSensor
    numberReplacement part
    numberDescriptionPaper-path sensor
    test nameTesting of sensor
    Paper feeder Tray 4
    cassette media-
    presence sensor
    1
    PS451CE530-69001PhotointerrupterP Tray 4 paper
    sensorRemove the Tray 4
    cassette, and then
    push the sensor
    lever.
    Paper feeder Tray 4
    cassette presence
    sensor
    1
    PS461 CE530-69001 Photointerrupter Q Tray 3 detectsensorRemove the Tray 4
    cassette, and then
    reinstall it.
    1Tray 3 and Tray 4 use PS451 and PS461 sensors.
    Access the MANUAL SENSOR TEST or the MANUAL SENSOR TEST 2 in the DIAGNOSTICS menu.
    1.Press the  Menu button 
    .
    2. Press the down arrow 
     button or the up arrow  button to navigate to the  DIAGNOSTICS menu,
    and then press the  OK button.
    3. Press the down arrow 
     button or the up arrow  button to navigate to the  MANUAL SENSOR
    TEST  or MANUAL SENSOR TEST 2  menu, and then press the OK  button.
    4. Press the down arrow 
     button or the up arrow  button to highlight a test, and then press the
    OK  button to select the test.
    5. To exit the diagnostic test, press the stop button 
    , and then select  EXIT DIAGNOSTICS .
    NOTE:Menus are not available during a test. During a test, the  OK button functions like the stop
    button 
    .
    Table 3-4   MANUAL SENSOR TEST 2 (special mode test) (continued)
    ENWW Tools for troubleshooting 139 
    						
    							A TOP (Top-of-Page) sensorTest the TOP sensor (PS215)
    1.Open the cartridge door, and then remove the print cartridge.
    2. Raise the registration shutter.
    3. Use a small screwdriver to activate the TOP sensor.
    Figure 3-3   Test the TOP sensor
    4.Check the control-panel display for sensor response.
    5. If there is no response, replace the TOP sensor.
    140 Chapter 3   Solve problems ENWW 
    						
    							B Fuser output sensorTest the fuser delivery sensor (PS2)
    1.Open the rear door.
    2. Slowly insert a piece of paper to activate the fuser delivery sensor.
    Figure 3-4   Test the fuser delivery sensor
    3.Check the control-panel display for a sensor response.
    4. If there is no response, replace the fuser.
    ENWW Tools for troubleshooting 141 
    						
    							C Duplex sensorTest the duplex media-feed sensor (PS502)
    1.Remove the Tray 2 cassette.
    2. Press the green lever to release the duplex media-feed assembly (metal tray).
    3. Raise the duplex media-feed assembly until it snaps into place.
    Figure 3-5   Test the duplex media-feed sensor
    4.Check the control-panel display for sensor response.
    5. If there is no response, replace the high-voltage power supply (duplex model).
    142 Chapter 3   Solve problems ENWW 
    						
    							D Paper width sensor 1Test the media width sensor (PS225)
    1.Open the cartridge door, and then remove the print cartridge.
    2. Raise and then lower the registration flap to activate the sensor.
    Figure 3-6   Test the media width sensor
    3.Check the control-panel display for a sensor response.
    4. If there is no response, replace the media width sensor PCA.
    ENWW Tools for troubleshooting 143 
    						
    							E Tray 3 feed sensorTest the Tray 3 media-feed sensor (PS8008)
    1.Remove the Tray 3 cassette.
    2. Use a small screwdriver to activate the sensor.
    Figure 3-7   Test the Tray 3 media-feed sensor
    3.Check the control-panel display for sensor response.
    4. If there is no response, replace the optional Tray 3 assembly.
    144 Chapter 3   Solve problems ENWW 
    						
    							F Tray 4 feed sensorTest the Tray 4 media-feed sensor (PS8008)
    1.Remove the Tray 4 cassette.
    2. Use a small screwdriver to activate the sensor.
    Figure 3-8   Test the Tray 4 media-feed sensor
    3.Check the control-panel display for sensor response.
    4. If there is no response, replace the optional Tray 4 assembly.
    ENWW Tools for troubleshooting 145 
    						
    							G FD tray full sensorTest the face-down media tray media-full (PS1)
    1.Raise and then lower the output-bin levers to activate the sensor.
    Figure 3-9   Test the face-down media tray media-full sensor
    2.Check the control-panel display for sensor response.
    3. If there is no response, replace the top-cover flag or the photo interrupter.
    146 Chapter 3   Solve problems ENWW 
    						
    All HP manuals Comments (0)