Thepower-metergraphsdisplayrecentserverpowerusage.ThegraphdataisresetwheniLOor theserverisreset.TheiLOfirmwareperiodicallysamplespeakpower,averagepower,andpower cap.Thefollowinggraphsaredisplayed: •24-HourHistoryGraph—Displaysthepowerusageoftheserverovertheprevious24hours. TheiLOfirmwarecollectspowerusageinformationfromtheserverevery5minutes.Thebar graphdisplaystheaveragevaluesinblueandthepeakvaluesinred.ThegraphshowsNo capsetduringahostpowerreset. •20-MinuteHistoryGraph—Displaysthepowerusageoftheserverovertheprevious20 minutes.TheiLOfirmwarecollectspowerusageinformationfromtheserverevery10seconds. Thebargraphdisplaystheaveragevaluesinblueandthepeakvaluesinred. TIP:Movethemousecursoroverthegraphtoviewthepowerusageforaspecificpointintime. Whenyouviewthepower-metergraphs,usetheDisplayOptionstocontrolthedisplayed information.Youcanviewminimum,average,peak,andcappowerinformation. UsingiLOPowerManagement241
Selectoneormoreofthefollowingcheckboxes,andthenclickRefreshPagetoupdatethegraphs. •Min(staticlow)—Theminimumvalueobservedduringameasurementperiod.Typically,the 20-minutegraphmeasuresaminimumvalueevery10seconds,whichmatchestheaverage value.The24-hourgraphcancaptureminimumvalueslowerthanthe5-minuteaveragevalue. •Avg—Themeanpowerreadingduringthesample. •Peak—Thehighestinstantaneouspowerreadingduringthesample.iLOrecordsthisvalueon asubsecondbasis. •Cap—Theconfiguredpowercapduringthesample.Ifthepowercapisnotconfiguredoris notsupported,theCapoptionisnotavailable. ◦Apowercaplimitsaveragepowerdrawforextendedperiodsoftime. ◦Powercapsarenotmaintainedduringserverreboots,resultingintemporaryspikesduring boot. ◦Powercapssetforlessthan50%ofthedifferencebetweenmaximumpowerandidle powermightbecomeunreachablebecauseofchangesintheserver.HPdoesnot recommendconfiguringpowercapsforlessthan20%.Configuringapowercapthatis toolowforthesystemconfigurationmightaffectsystemperformance. ◦FormoreinformationaboutHPInsightControlpowermanagementsoftware,seehttp:// www.hp.com/go/dpc. Thefollowingoptionsarealsoavailable: •PowerUnit—SelectavaluefromthePowerUnitlisttochangethepowerreadingdisplayto wattsorBTU/hr. •RefreshPage—ClicktheRefreshPagebuttontoupdatethehistorygraphs. Viewingthecurrentpowerstate Toviewthecurrentpowerstate,navigatetothePowerManagement→PowerMeterpage.Scroll totheCurrentStatesection. ThevaluesdisplayedintheCurrentStatetablevarydependingontheservertype: •PresentPowerReading—Thecurrentpowerreadingfromtheserver.Thisvalueisdisplayed forallHPProLiantservers. •PresentPowerCap—Theconfiguredpowercapfortheserver.Thisvalueis0ifthepower capisnotconfigured.ThisvalueisdisplayedforHPProLiantMLandDLservers,andserver blades. •PowerInputVoltage—Thesuppliedinputvoltagefortheserver.ThisvalueisdisplayedforHP ProLiantMLandDLservers. •PowerRegulatorMode—TheconfiguredHPPowerRegulatorforProLiantmode.Thisvalueis displayedforallHPProLiantservers.Forinformationaboutthepossiblesettings,see “Configuringpowersettings”(page243). 242UsingiLO
•PowerSupplyCapacity—Theserverpowercapacity.ThisvalueisdisplayedforHPProLiant SLservers. •PeakMeasuredPower—Thehighestmeasuredpowerreading.ThisvalueisdisplayedforHP ProLiantSLservers. Viewingtheserverpowerhistory Toviewtheserverpowerhistory,navigatetothePowerManagement→PowerMeterpage.Scroll tothePowerHistorysection. ThePowerHistorytableshowspowerreadingsfromthreetimeperiods:5minutes,20minutes, and24hours. •AveragePower—Theaverageofthepowerreadingsforthespecifiedtimeperiod.Iftheserver hasnotbeenrunningforthespecifiedtimeperiod,thevalueistheaverageofallreadings sincetheserverbooted. •MaximumPower—Themaximumpowerreadingfromtheserverforthespecifiedtimeperiod. Iftheserverhasnotbeenrunningforthespecifiedtimeperiod,thevalueisthemaximumof allreadingssincetheserverbooted. •MinimumPower—Theminimumpowerreadingfromtheserverforthespecifiedtimeperiod. Iftheserverhasnotbeenrunningforthespecifiedtimeperiod,thevalueistheminimumof allreadingssincetheserverbooted. Configuringpowersettings ThePowerSettingspageenablesyoutoviewandcontrolthepowermanagementfeaturesofthe server.Thepowermanagementfeaturesonthispagevarybasedontheserverconfiguration.You musthavetheConfigureiLOSettingsprivilegetochangethevaluesonthispage. ConfiguringPowerRegulatorsettings TheHPPowerRegulatorforProLiantfeatureenablesiLOtodynamicallymodifyprocessorfrequency andvoltagelevels,basedonoperatingconditions,toprovidepowersavingswithminimaleffect onperformance.ThePowerSettingspageallowsyoutoviewandcontrolthePowerRegulator Modeoftheserver. ToconfigurethePowerRegulatorsettings: UsingiLOPowerManagement243
1.NavigatetothePowerManagement→PowerSettingspage. 2.Selectoneofthefollowingoptions: •HPDynamicPowerSavingsMode—Automaticallyvariesprocessorspeedandpower usagebasedonprocessorutilization.Thisoptionallowsthereductionofoverallpower consumptionwithlittleornoimpacttoperformance.ItdoesnotrequireOSsupport. •HPStaticLowPowerMode—Reducesprocessorspeedandpowerusage.Thisoption guaranteesalowermaximumpowerusageforthesystem. •HPStaticHighPerformanceMode—Processorswillrunatmaximumpower/performance atalltimes,regardlessoftheOSpowermanagementpolicy. •OSControlMode—Processorswillrunatmaximumpower/performanceatalltimes, unlesstheOSenablesapowermanagementpolicy. 3.ClickApply. Oneofthefollowingmessagesappears: •FortheHPDynamicPowerSavingsMode,HPStaticLowPowerMode,andHPStaticHigh PerformanceModesettings:Power Regulator Settings changed. •FortheOSControlModesetting:You must reboot the server to invoke this change of the Power Regulator Settings. ThePowerRegulatorsettingscannotbechangedwhiletheserverisinPOST.Ifthesettings donotchangeafteryouclickApply,theservermightbeinthebootprocessorrequire rebooting.ExitanyROM-basedprogramthatisrunning,allowPOSTtocomplete,andthen trytheoperationagain. 4.IfiLOnotifiedyouthatarebootisrequired,reboottheserver. 244UsingiLO
Configuringpowercappingsettings ThePowerCappingSettingssectionenablesyoutoviewmeasuredpowervalues,setapower cap,anddisablepowercapping. •TheMeasuredPowerValuessectionliststhefollowing: MaximumAvailablePower—Thepowersupplycapacityforanonbladeserver,orthe initialpower-onrequestvalueforaserverblade. ◦ ◦PeakObservedPower—Themaximumobservedpowerfortheserver ◦MinimumObservedPower—Theminimumobservedpowerfortheserver DuringPOST,theROMrunstwopowerteststhatdeterminethepeakandminimumobserved powervalues. •PowercappingsettingsaredisabledwhentheserverispartofanEnclosureDynamicPower Cap.ThesevaluesaresetandmodifiedbyusingOnboardAdministratororInsightControl PowerManagement. •UsethePowerCapThresholdsasguidelinesforconfiguringapowercap. MaximumPowerCap—Themaximumpoweravailablefortheserver.Theservermustnot exceedthisvalue. ◦ ◦MinimumHigh-PerformanceCap—Themaximumpowerthattheserverusesinthecurrent configuration.Apowercapsettothisvaluedoesnotaffectserverperformance. ◦MinimumPowerCap—Theminimumpowerthattheserverusers.Apowercapsettothis valuereducestheserverpowerusagetotheminimum,whichresultsinserverperformance degradation. •Whenapowercapisset,theaveragepowerreadingoftheservermustbeatorbelowthe powercapvalue. •YoucannotusetheiLOwebinterfacetoconfigurethepowercappingsettingsforSLservers. UseoneofthefollowingtoolstoconfigurethepowercappingsettingsforSLservers: ◦PowerInterfaceControlUtility—Thisutilityisavailableatthefollowingwebsite:http:// h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp? prodTypeId=15351&prodSeriesId=4324034& swItem=MTX-cb0c48d305d24a4dbe80e5eecc&prodNameId=5037746. ◦HPProLiantSLAdvancedPowerManager—Formoreinformation,seetheHPProLiantSL AdvancedPowerManagerUserGuide. Toconfigureapowercap: 1.NavigatetothePowerManagement→PowerSettingspage. 2.SelecttheEnablepowercappingcheckbox. 3.EnterthePowerCapValueinwatts,BTU/hr,orasapercentage. Thepercentageisthedifferencebetweenthemaximumandminimumpowervalues.The powercapvaluecannotbesetbelowtheserverminimumpowervalue. Whenvaluesaredisplayedinwatts,clickShowvaluesinBTU/hrtochangethedisplayto BTU/hr.WhenvaluesaredisplayedinBTU/hr,clickShowvaluesinWattstochangethe displaytowatts. 4.ClickApply. ConfiguringSNMPalertsettings TheSNMPAlertonBreachofPowerThresholdsectionenablesthesendingofanSNMPalertwhen powerconsumptionexceedsadefinedthreshold. UsingiLOPowerManagement245
ToconfiguretheSNMPalertsettings: 1.NavigatetothePowerManagement→PowerSettingspage. 2.SelectavalueintheWarningTriggerlist. Thewarningtriggerdetermineswhetherwarningsarebasedonpeakpowerconsumption, averagepowerconsumption,oriftheyaredisabled. 3.IfyouselectedPeakPowerConsumptionorAveragePowerConsumptionintheWarning Triggerlist,enterthefollowing: •WarningThreshold—Setsthepowerconsumptionthreshold,inwatts.Ifpowerconsumption exceedsthisvalueforthespecifiedtimeduration,anSNMPalertistriggered. •Duration—Setsthelengthoftime,inminutes,thatpowerconsumptionmustremainabove thewarningthresholdbeforeanSNMPalertistriggered.Themaximumdurationis240 minutes,andthedurationmustbeamultipleof5. 4.ClickApplytosavetheconfiguration. Configuringthepersistentmouseandkeyboard TheOtherSettingssectiononthePowerSettingspageallowsyoutoenableordisablethepersistent keyboardandmousefeature. Whenthisfeatureisenabled,theiLOvirtualkeyboardandmousearealwaysconnectedtothe iLOUHCIUSBcontroller.Whenthisfeatureisdisabled,theiLOvirtualkeyboardandmouseare connecteddynamicallytotheiLOUHCIcontrolleronlywhenaRemoteConsoleapplicationis openandconnectedtoiLO.DisablingthefeatureallowssomeHPserverstoincreasepowersavings by15wattswhentheserveroperatingsystemisidleandnovirtualUSBkeyboardandmouseare connected. Forexample,thepowersavingsfora24–hourperiodmightbe15wattsx24hours,or360watt hours(.36kilowatt-hours). Thepersistentmouseandkeyboardfeatureisdisabledbydefault. Tochangethepersistentmouseandkeyboardsetting: 1.NavigatetothePowerManagement→PowerSettingspage. 2.SelectorcleartheEnablepersistentmouseandkeyboardcheckbox. 3.ClickApplytosavetheconfiguration. UsingiLOwithOnboardAdministrator OAistheenclosuremanagementprocessor,subsystem,andfirmwarebasethatsupportstheHP BladeSystemandallmanageddevicesintheenclosure. UsingtheActiveOnboardAdministrator TheBLc-Class→ActiveOnboardAdministratorpageprovidesgeneralinformationabouttheprimary OAintheenclosureinwhichtheiLOprocessorislocated.Thispageisdisplayedonlywhenthere isanenclosure. 246UsingiLO
Thedisplayedinformationandoptionsfollow: •MACAddress—TheMACaddressoftheactiveOA. •SystemHealth—ThehealthoftheactiveOA,asreportedbytheOA. AvalueofunknownmeansthattheOAhealthhasnotbeenreportedtoiLO. •BladeLocation—Thelocation(enclosurebay)ofthebladethatishostingthecurrentiLOsession. •EnclosureName—TheenclosurethattheactiveOAismanaging.Youcanchangethisvalue throughtheOA. •RackName—TherackthatcontainstheenclosuremanagedbytheactiveOA.Youcanchange thisvaluethroughtheOA. StartingtheOnboardAdministratorGUI 1.NavigatetotheBLc-Class→ActiveOnboardAdministratorpage. 2.IftheOAsupportsmultipleaddresses,selecttheaddresstousefromtheoptionsintheOnboard AdministratorAddressSelectiontable. Dependingontheconfiguration,thefollowingoptionsmightbeavailable: •IPv4 •IPv6SLAAC •IPv6Static •IPv6DHCP 3.ClickLaunch. TheOAGUIopensinanewbrowserwindow. TogglingtheenclosureUIDlight TochangethestateoftheenclosureUIDwhereiLOislocated,clicktheToggleUIDbutton. TheUIDstatusonthispagerepresentstheenclosureUIDstatuswhentheiLOpageloaded.To updatethestatus,refreshthepage. UsingiLOwithOnboardAdministrator247
EnclosurebayIPaddressing TheFirstTimeSetupWizardpromptsyoutosetupyourenclosurebayIPaddressing.Formore informationaboutthewizard,seetheHPBladeSystemOnboardAdministratorUserGuide. DynamicPowerCappingforserverblades DynamicPowerCappingisaniLOfeatureavailableforc-Classserverblades,andisaccessed throughOA.DynamicPowerCappingisavailableonlyifyoursystemhardwareplatform,BIOS (ROM),andpowermicrocontrollerfirmwareversionsupportthisfeature.Ifyoursystemsupports DynamicPowerCapping,iLOautomaticallyrunsinDynamicPowerCappingmode. Forinformationaboutthepowersettingoptionsforc-Classserverblades,seetheHPBladeSystem OnboardAdministratorUserGuide. iLOvirtualfan Inc-Classbladeservers,OAcontrolstheenclosurefans(alsocalledvirtualfans).TheiLOfirmware cannotdetecttheseenclosurefans.Instead,theiLOfirmwaremonitorsanambienttemperature sensorlocatedonthebladeserver.ThisinformationisdisplayedontheiLOwebinterface,andis retrievedbyOAperiodically.OAusesthesensorinformationcollectedfromalliLOprocessorsin theenclosuretodetermineenclosurefanspeeds. iLOoption TheiLO-DeviceBaypageinOAprovidesthefollowinglinks: •WebAdministration—StartstheiLOwebinterface •IntegratedRemoteConsole—Startsthe.NETIRC •RemoteConsole—StartstheJavaIRC ClickingalinkonthispageopenstherequestediLOsessioninanewwindowthatusesSSO, whichdoesnotrequireaniLOusernameorpassword.Ifyourbrowsersettingspreventnew windowsfromopening,theselinksdonotworkcorrectly. 248UsingiLO
IPMIservermanagement ServermanagementthroughIPMIisastandardmethodforcontrollingandmonitoringtheserver. TheiLOfirmwareprovidesservermanagementbasedontheIPMIversion2.0specification,which definesthefollowing: •Monitoringofsysteminformationsuchasfans,temperatures,andpowersupplies •Recoverycapabilitiessuchassystemresetsandpoweron/offoperations •Loggingcapabilitiesforabnormaleventssuchasover-temperaturereadingsorfanfailures •Inventorycapabilitiessuchasidentificationoffailedhardwarecomponents IPMIcommunicationsdependontheBMCandtheSMS.TheBMCmanagestheinterfacebetween theSMSandtheplatformmanagementhardware.TheiLOfirmwareemulatestheBMCfunctionality, andtheSMSfunctionalitycanbeprovidedbyvariousindustry-standardtools.Formoreinformation, seetheIPMIspecificationontheIntelwebsiteathttp://www.intel.com/design/servers/ipmi/ tools.htm. TheiLOfirmwareprovidestheKCSinterface,oropeninterface,forSMScommunications.The KCSinterfaceprovidesasetofI/Omappedcommunicationsregisters.Thedefaultsystembase addressfortheI/O-mappedSMSinterfaceis0xCA2,anditisbytealignedatthissystemaddress. TheKCSinterfaceisaccessibletotheSMSsoftwarerunningonthelocalsystem.Examplesof compatibleSMSsoftwareapplicationsfollow: •IPMIversion2.0CommandTestTool—Alow-levelMS-DOScommand-linetoolthatenables hex-formattedIPMIcommandstobesenttoanIPMIBMCthatimplementstheKCSinterface. IPMIservermanagement249
YoucandownloadthistoolfromtheIntelwebsiteathttp://www.intel.com/design/servers/ ipmi/tools.htm. •IPMItool—AutilityformanagingandconfiguringdevicesthatsupporttheIPMIversion1.5 andversion2.0specifications.IPMItoolcanbeusedinaLinuxenvironment.Youcandownload thistoolfromtheIPMItoolwebsiteathttp://ipmitool.sourceforge.net/index.html. WhenemulatingaBMCfortheIPMIinterface,iLOsupportsallmandatorycommandslistedinthe IPMIversion2.0specification.TheSMSshouldusethemethodsdescribedinthespecificationfor determiningwhichIPMIfeaturesareenabledordisabledintheBMC(forexample,usingtheGet Device IDcommand). Iftheserveroperatingsystemisrunning,andtheiLOhealthdriverisenabled,anyIPMItraffic throughtheKCSinterfacecanaffecthealthdriverperformanceandoverallsystemhealth.Donot issueanyIPMIcommandsthroughtheKCSinterfacethatmighthaveanegativeeffectonhealth drivermonitoring.ThisrestrictionincludesanycommandthatsetsorchangesIPMIparameters, suchasSet Watchdog TimerandSet BMC Global Enabled.AnyIPMIcommandthat simplyreturnsdataissafetouse,suchasGet Device IDandGet Sensor Reading. UsingiLOwithHPInsightControlserverprovisioning HPInsightControlserverprovisioningisintegratedwithiLOtoenablethemanagementofremote serversandtheperformanceofRemoteConsoleoperations,regardlessofthestateoftheoperating systemorhardware. ThedeploymentserverenablesyoutousethepowermanagementfeaturesofiLOtopoweron, poweroff,orcyclepoweronthetargetserver.Eachtimeaserverconnectstothedeployment server,thedeploymentserverpollsthetargetservertoverifythataniLOdeviceisinstalled.If installed,theservergathersinformation,includingtheDNSname,IPaddress,anduserloginname. Securityismaintainedbyrequiringtheusertoenterthecorrectpasswordforthatusername. FormoreinformationaboutHPInsightControlserverprovisioning,seethedocumentationonthe HPInsightControlwebsiteathttp://www.hp.com/go/insightcontrol. UsingHPEnterpriseSecureKeyManagerwithiLO TheKeyManagerpageenablesyoutoconnecttoanoperationalkeymanager,changeredundancy settings,viewthekeymanagerconnectionsettings,testtheconnection,andviewkeymanagement events. iLO41.40andlatersupportstheHPEnterpriseSecureKeyManager3.1andlater,whichcan beusedinconjunctionwithHPSecureEncryption. •HPSecureEncryptionsupportsHPSmartArrayControllersandprovidesdata-at-restencryption fordirect-attachedHDDorSSDstorageconnectedtoHPProLiantservers.Itprovidesan integratedsolutiontoencryptingHDDorSSDvolumesbyusing256-bitXTS-AESalgorithms. •HPEnterpriseSecureKeyManagergenerates,stores,serves,controlsandauditsaccessto dataencryptionkeys.Itenablesyoutoprotectandpreserveaccesstobusiness-critical,sensitive, data-at-restencryptionkeys. •HPiLOmanagesthekeyexchangebetweentheESKMandtheSmartArrayController.iLO usesauniqueuseraccountbasedonitsownMACaddressforcommunicatingwiththeESKM. Fortheinitialcreationofthisaccount,iLOusesadeploymentuseraccountthatpre-existson theESKMwithadministratorprivileges.Formoreinformationaboutthedeploymentuser account,seetheHPSecureEncryptionInstallationandUserGuide ThisfeatureandmanyothersarepartofaniLOlicensingpackage.Formoreinformationabout iLOlicensing,seethefollowingwebsite:http://www.hp.com/go/ilo/licensing. ForinformationaboutHPSecureEncryptionandESKM,seetheHPSecureEncryptionInstallation andUserGuide 250UsingiLO