•SNMPAlertDestination(s)—TheIPaddressesorFQDNsofuptothreeremotemanagement systemsthatwillreceiveSNMPalertsfromiLO. NOTE:Typically,youentertheHPSIMserverconsoleIPaddressinoneoftheSNMP AlertDestination(s)boxes. WhenSNMPAlertDestinationsareconfiguredusingFQDN,andDNSprovidesboth IPv4andIPv6addressesforthoseFQDNs,iLOwillsendtrapstotheaddressspecified bytheiLOClientApplicationsuseIPv6firstsettingonthenetworkconfigurationIPv6 page.IfiLOClientApplicationsuseIPv6firstisselected,trapswillbesenttoIPv6addresses (whenavailable).WheniLOClientApplicationsuseIPv6firstisnotselected,trapswill besenttoIPv4addresses(whenavailable). •SNMPPort—TheportusedforSNMPcommunications.Thisvalueisread-only,butcan bemodifiedontheAdministration→AccessSettingspage. ClicktheSNMPPortlinktonavigatetotheAdministration→AccessSettingspage.For moreinformation,see“ConfiguringiLOaccesssettings”(page57). 5.ClickApplytosavetheconfiguration. ConfiguringSNMPv3Users iLO41.20orlatersupportsSNMPv3authenticationwhenyouuseAgentlessManagement. ThefollowingsecurityfeaturesofSNMPv3enablesecuredatacollectionfromSNMPagents: •Messageintegritypreventstamperingduringpackettransmission. •Encryptionpreventspacketsnooping. •Authenticationensuresthatpacketsarefromavalidsource. Bydefault,SNMPv3supportstheUser-basedSecurityModel.Withthismodel,securityparameters areconfiguredatboththeagentlevelandthemanagerlevel.Messagesexchangedbetweenthe agentandthemanageraresubjecttoadataintegritycheckanddataoriginauthentication. iLOsupportsthreeuserprofilesinwhichyoucansettheSNMPv3USMparameters. ToeditSNMPv3userprofiles: 1.NavigatetotheAdministration→Managementpage. 2.ClicktheSNMPSettingstabandscrolltotheSNMPv3Userssection. 3.SelectauserprofileintheSNMPv3Userssection,andthenclickEdit. TheiLOwebinterfaceupdatestoshowtheSNMPv3useroptions. ConfiguringiLOManagementsettings111
4.Enterthefollowinginformation: •SecurityName—Theuserprofilename.Enteranalphanumericstringof1to32characters. •AuthenticationProtocol—Setsthemessagedigestalgorithmtouseforencodingthe authorizationpassphrase.Themessagedigestiscalculatedoveranappropriateportion ofanSNMPmessage,andisincludedaspartofthemessagesenttotherecipient.Select MD5orSHA. •AuthenticationPassphrase—Setsthepassphrasetouseforsignoperations.Enteravalue of8to49characters. •PrivacyProtocol—Setstheencryptionalgorithmtouseforencodingtheprivacypassphrase. AportionofanSNMPmessageisencryptedbeforetransmission.SelectAESorDES. •PrivacyPassphrase—Setsthepassphraseusedforencryptoperations.Enteravalueof 8to49characters. 5.ClickApplytosavetheuserprofile. ConfiguringtheSNMPv3EngineID TheSNMPv3EngineIDsetstheuniqueidentifierofanSNMPenginebelongingtoanSNMPagent entity.YoucanconfigurethisvaluewhenAgentlessManagementisselected. ToconfiguretheSNMPv3EngineID: 1.NavigatetotheAdministration→Managementpage. 2.ClicktheSNMPSettingstabandscrolltotheSNMPv3Userssection. 3.EnteravalueintheSNMPv3EngineIDbox. Thisvaluemustbeahexadecimalstringof6to32characters,andmustbeanevennumber ofcharacters,excludingthepreceding0x(forexample,0x01020304abcdef). 4.ClickApply. ConfiguringSNMPalerts YoucanconfiguretheTrapSourceIdentifier,iLOSNMPalerts,forwardingofInsightManagement AgentSNMPalerts,ColdStartTrapbroadcast,andSNMPv1traps. ToconfigureSNMPalerts: 1.NavigatetotheAdministration→Managementpage. 2.ClicktheSNMPSettingstabandscrolltotheSNMPAlertssection. 112ConfiguringiLO
3.ConfiguretheTrapSourceIdentifierbyselectingiLOHostnameorOSHostname. ThissettingdeterminesthehostnamethatisusedintheSNMP-definedsysNamevariable wheniLOgeneratesSNMPtraps.ThedefaultsettingisiLOHostname. NOTE:ThehostnameisanOSconstructanddoesnotremainpersistentwiththeserver whentheharddrivesaremovedtoanewserverplatform.TheiLOsysName,however,remains persistentwiththesystemboard. 4.Enableordisablethefollowingalerttypes: •iLOSNMPAlerts—AlertconditionsthatiLOdetectsindependentlyofthehostoperating systemcanbesenttospecifiedSNMPalertdestinations,suchasHPSIM.Ifthisoption isdisabled,notrapswillbesenttotheconfiguredSNMPalertdestinations. •ForwardInsightManagerAgentSNMPAlerts—Alertconditionsdetectedbythehost managementagentscanbeforwardedtoSNMPalertdestinationsthroughiLO.These alertsaregeneratedbytheInsightManagementAgents,whichareavailableforeach supportedoperatingsystem.InsightManagementAgentsmustbeinstalledonthehost servertoreceivethesealerts. •ColdStartTrapBroadcast—Whenthisoptionisenabled,ColdStartTrapisbroadcastto asubnetbroadcastaddressifnovalidtrapdestinationsareconfigured. TheColdStartTrapisbroadcastwhenanyofthefollowingconditionsismet: ◦SNMPAlertDestinationsarenotconfigured. ◦iLOfailedtoresolvealloftheSNMPAlertDestinationstoIPaddresses. ThesubnetbroadcastaddressforanIPv4hostisobtainedbyperformingabitwiselogical ORoperationbetweenthebitcomplementofthesubnetmaskandthehostIPaddress. Forexample,thehost192.168.1.1,whichhasthesubnetmask255.255.252.0,has thebroadcastaddress192.168.1.1 | 0.0.3.255 = 192.168.3.255. •SNMPv1Traps—Whenenabled,SNMPv1trapsaresenttotheremotemanagement systemsconfiguredintheSNMPAlertDestination(s)boxes. 5.Optional:ClickSendTestAlerttogenerateatestalertandsendittotheTCP/IPaddressesin theSNMPAlertDestination(s)boxes. TestalertsincludeanInsightManagementSNMPtrap,andareusedtoverifythenetwork connectivityofiLOinHPSIM.OnlyuserswiththeConfigureiLOSettingsprivilegecansend testalerts. Afterthealertisgenerated,aconfirmationdialogboxopens.ChecktheHPSIMconsolefor receiptofthealert. 6.ClickApplytosavetheconfiguration. UsingtheAMSControlPaneltoconfigureSNMPandSNMPalerts(Windowsonly) 1.OpentheAgentlessManagementServiceControlPanel. 2.ClicktheSNMPtab. ConfiguringiLOManagementsettings113
3.UpdatetheSNMPsettings. Foradescriptionoftheavailablesettings,see“ConfiguringSNMPsettings”(page109)and “ConfiguringSNMPalerts”(page112). 4.Optional:ClickSendTestTraptogenerateatestalertandsendittotheTCP/IPaddressesin theTrapDestination(s)boxes. TestalertsincludeanInsightManagementSNMPtrapandareusedtoverifythenetwork connectivityofiLOinHPSIM.OnlyusersthathavetheConfigureiLOSettingsprivilegecan sendtestalerts. Afterthealertisgenerated,aconfirmationdialogboxopens.ChecktheHPSIMconsolefor receiptofthealert. 5.ClickApplytosavetheconfiguration. SNMPtraps Table3(page114)liststheSNMPtrapsthatyoucangeneratewithiLOandHPProLiantGen8and Gen9servers. FormoreinformationabouttheseSNMPtraps,seethefollowingfilesintheInsightManagement MIBupdatekitforHPSIM: •cpqida.mib •cpqhost.mib •cpqhlth.mib •cpqsm2.mib •cpqide.mib •cpqscsi.mib •cpqnic.mib •cpqstsys.mib •cpqstdeq.mib Table3SNMPtraps DescriptionSNMPtrapname SNMPhasbeeninitialized,thesystemhascompletedPOST,or AMShasstarted. ColdStartTrap0 SNMPhasdetectedanauthenticationfailure.AuthenticationFailureTrap4 114ConfiguringiLO
Table3SNMPtraps(continued) DescriptionSNMPtrapname Anuncorrectablemachinecheckexceptionhasbeendetectedin aprocessor. cpqSeCpuStatusChange1006 AchangehasbeendetectedinthestatusoftheSmartArray controller. cpqDa6CntlrStatusChange3033 AchangehasbeendetectedinthestatusofaSmartArraylogical drive. cpqDa6LogDrvStatusChange3034 AchangehasbeendetectedinthestatusofaSmartArraycache module. cpqDa6AccelStatusChange3038 TheSmartArraycachemodulehaslostbackuppower.cpqDa6AccelBadDataTrap3039 TheSmartArraycachemodulebackuppowerhasfailed.cpqDa6AccelBatteryFailed3040 AchangehasbeendetectedinthestatusofaSmartArrayphysical drive. cpqDa7PhyDrvStatusChange3046 AchangehasbeendetectedinthestatusofaSmartArrayspare drive. cpqDa7SpareStatusChange3047 AchangehasbeendetectedintheSSDwearstatusofaSmart Arrayphysicaldrive. cpqDaPhyDrvSSDWearStatusChange3049 Theserverwasshutdownduetoathermalanomalyandisnow operational. cpqHe3ThermalConfirmation6026 OneormorePOSTerrorshaveoccurred.cpqHe3PostError6027 Thefault-tolerantpowersupplieshavelostredundancyforthe specifiedchassis. cpqHe3FltTolPowerRedundancyLost6032 Afault-tolerantpowersupplyhasbeeninserted.cpqHe3FltTolPowerSupplyInserted6033 Afault-tolerantpowersupplyhasbeenremoved.cpqHe3FltTolPowerSupplyRemoved6034 Thefault-tolerantfanconditionhasbeensettoDegraded.cpqHe3FltTolFanDegraded6035 Thefault-tolerantfanconditionhasbeensettoFailed.cpqHe3FltTolFanFailed6036 Thefault-tolerantfanshavelostredundancy.cpqHe3FltTolFanRedundancyLost6037 Afault-tolerantfanhasbeeninserted.cpqHe3FltTolFanInserted6038 Afault-tolerantfanhasbeenremoved.cpqHe3FltTolFanRemoved6039 ThetemperaturestatushasbeensettoDegraded,andthe temperatureisoutsidethenormaloperatingrange.Depending onthesystemconfiguration,thissystemmightbeshutdown. cpqHe3TemperatureDegraded6041 ThetemperaturestatushasbeensettoOK.cpqHe3TemperatureOk6042 Thefault-tolerantpowersupplyconditionhasbeenresettoOK.cpqHe4FltTolPowerSupplyOk6048 Thefault-tolerantpowersupplyconditionhasbeensettoDegraded.cpqHe4FltTolPowerSupplyDegraded6049 Thefault-tolerantpowersupplyconditionhasbeensettoFailed.cpqHe4FltTolPowerSupplyFailed6050 TheAdvancedMemoryProtectionsubsystemhasdetecteda memoryfault.MirroredMemoryhasbeenactivated. cpqHeResilientMemMirroredMemoryEngaged6051 Thefault-tolerantpowersupplieshavereturnedtoaredundant state. cpqHe3FltTolPowerRedundancyRestore6054 Thefault-tolerantfanshavereturnedtoaredundantstate.cpqHe3FltTolFanRedundancyRestored6055 Memoryerrorshavebeencorrected,butthememorymodule shouldbereplaced. cpqHe5CorrMemReplaceMemModule6064 ConfiguringiLOManagementsettings115
Table3SNMPtraps(continued) DescriptionSNMPtrapname Thefault-tolerantpowersupplyinthespecifiedchassisandbay reportedACpowerloss. cpqHe4FltTolPowerSupplyACpowerloss6069 TheHPSmartStoragebatteryhasfailed.cpqHeSysBatteryFailed6070 TheHPSmartStoragebatteryhasbeenremoved.cpqHeSysBatteryRemoved6071 Achangehasbeendetectedinthefanstatusofthestoragesystem.cpqSs6FanStatusChange8029 Achangehasbeendetectedinthetemperaturestatusofthe storagesystem. cpqSs6TempStatusChange8030 Achangehasbeendetectedinthepowerstatusofthestorage system. cpqSs6PwrSupplyStatusChange8031 Theserverpowerhasbeenreset.cpqSm2ServerReset9001 Themaximumunauthorizedloginattemptthresholdhasbeen exceeded. cpqSm2UnauthorizedLoginAttempts9003 iLO4hasdetectedaSelfTestError.cpqSm2SelfTestError9005 iLO4hasdetectedthatthesecurityoverridejumperhasbeen toggledtotheengagedposition. cpqSm2SecurityOverrideEngaged9012 iLO4hasdetectedthatthesecurityoverridejumperhasbeen toggledtothedisengagedposition. cpqSm2SecurityOverrideDisengaged9013 Theserverhasbeenpoweredon.cpqSm2ServerPowerOn9017 Theserverhasbeenpoweredoff.cpqSm2ServerPowerOff9018 Arequestwasmadetopowerontheserver,buttheservercould notbepoweredonbecauseofafailurecondition. cpqSm2ServerPowerOnFailure9019 CommunicationwithInsightRemoteSupportorInsightOnlinehas failed. cpqSm2IrsCommFailure9020 Generictrap.VerifiesthattheSNMPconfiguration,clientSNMP console,andnetworkareoperatingcorrectly.Youcanusethe cpqHo2GenericTrap11003 iLOwebinterfacetogeneratethisalerttoverifyreceiptofthealert ontheSNMPconsole. Apowerthresholdhasbeenexceeded.cpqHo2PowerThresholdTrap11018 Achangeinthehealthstatusoftheserverhasoccurred.cpqHoMibHealthStatusArrayChangeTrap11020 AMSdetectedachangeinthestatusofanSASorSATAphysical drive. cpqSasPhyDrvStatusChange5022 AMSdetectedachangeinthestatusofanATAdiskdrive.cpqIdeAtaDiskStatusChange14004 AMSdetectedthatconnectivitywasrestoredtoalogicalnetwork adapter. cpqNic3ConnectivityRestored18011 AMSdetectedthatthestatusofalogicalnetworkadapterchanged toFailed. cpqNic3ConnectivityLost18012 ConfiguringInsightManagementintegration 1.NavigatetotheAdministration→Managementpage. 2.ClicktheSNMPSettingstabandscrolltotheInsightManagementIntegrationsection. 116ConfiguringiLO
3.ConfiguretheHPSystemManagementHomepage(HPSMH)FQDN/IPAddress. ThisvaluesetsthebrowserdestinationoftheInsightAgentlinkoniLOpages. EntertheFQDNorIPaddressofthehostserver.Theprotocol(https://)andportnumber (:2381)areaddedautomaticallytotheIPaddressorDNSnametoallowaccessfromiLO. IftheURLissetthroughanothermethod(forexample,HPQLOCFG),clickthebrowserrefresh buttontodisplaytheupdatedURL. 4.SelecttheLevelofDataReturned. ThissettingcontrolsthecontentofananonymousdiscoverymessagereceivedbyiLO.The informationreturnedisusedforHPSIMHTTPidentificationrequests.Thefollowingoptions areavailable: •Enabled(iLO+ServerAssociationData)(default)—EnablesHPSIMtoassociatethe managementprocessorwiththehostserver,andprovidessufficientdatatoenable integrationwithHPSIM. •Disabled(NoResponsetoRequest)—PreventsiLOfromrespondingtoHPSIMrequests. 5.Optional:ClickViewXMLReplytoviewtheresponsethatisreturnedtoHPSIMwhenit requestsiLOmanagementprocessoridentificationbyusingtheprovidedaddress. 6.ClickApplytosavethechanges. FormoreinformationabouttheInsightManagementAgents,navigatetotheInformation→Insight Agentpage. ConfiguringAlertMailsettings iLOAlertMailenablesyoutoconfigureiLOtosendalertconditionsdetectedindependentlyofthe hostoperatingsystemtoaspecifiedemailaddress.iLOmailalertsincludemajorhostsystem events. YoumusthavetheConfigureiLOSettingsprivilegetochangethesesettings. ThisfeatureandmanyothersarepartofaniLOlicensingpackage.Formoreinformationabout iLOlicensing,seethefollowingwebsite:http://www.hp.com/go/ilo/licensing. ConfiguringiLOManagementsettings117
EnablingAlertMail 1.NavigatetotheAdministration→Management→AlertMailpage. 2.SelecttheEnableiLOAlertMailcheckbox. 3.Enterthefollowinginformation: •EmailAddress—ThedestinationemailaddressforiLOemailalerts.Thisstringcanbeup to63charactersandshouldbeinstandardemailaddressformat.Youcanenteronly oneemailaddress. •SenderDomain—Thedomainnamespecifiedinthesender(From)emailaddress.The senderemailaddressisformedbyusingtheiLOnameashostname,andthesubject stringasdomainname.Ifnodomainnameisspecified,theiLOdomainname,which maynotbeacceptedbyallSMTPservers,isused.Thisstringcanbeupto63characters. •SMTPPort—TheportthattheSMTPserverwilluseforunauthenticatedSMTPconnections. Thedefaultvalueis25. •SMTPServer—TheIPaddressorDNSnameoftheSMTPserverortheMSA.Thisserver cooperateswiththeMTAtodelivertheemail.Thisstringcanbeupto63characters. 4.Optional:ClickSendTestAlertMailtosendatestmessagetotheconfiguredemailaddress. ThisbuttonisavailableonlywhenAlertMailisenabled. 5.ClickApplytosavethechanges. DisablingAlertMail 1.NavigatetotheAdministration→Management→AlertMailpage. 2.CleartheEnableiLOAlertMailcheckbox. 3.ClickApplytosavethechanges. ConfiguringRemoteSyslogsettings TheRemoteSyslogfeatureallowsiLOtosendeventnotificationmessagestoSyslogservers.The iLOfirmwareRemoteSyslogincludestheIMLandiLOEventLog. YoumusthavetheConfigureiLOSettingsprivilegetochangethesesettings. ThisfeatureandmanyothersarepartofaniLOlicensingpackage.Formoreinformationabout iLOlicensing,seethefollowingwebsite:http://www.hp.com/go/ilo/licensing. 118ConfiguringiLO
EnablingiLORemoteSyslog 1.NavigatetotheAdministration→Management→RemoteSyslogpage. 2.SelecttheEnableiLORemoteSyslogcheckbox. 3.Enterthefollowinginformation: •RemoteSyslogPort—TheportnumberthroughwhichtheSyslogserverislistening. Thedefaultvalueis514. •RemoteSyslogServer—TheIPaddress,FQDN,IPv6name,orshortnameoftheserver runningtheSyslogservice.Thisstringcanbeupto127characters. OnLinuxsystems,systemeventsareloggedbyatoolcalledsyslog.Thistoolshouldbe installedonallLinuxsystems.Youcansetasyslogserveronaremotesystemthatwill actasacentralloggingsystemforiLOsystems.Thisway,iftheiLORemoteSyslogfeature isenablediniLO,itcansenditslogstothesyslogserver. 4.Optional:ClickSendTestSyslogtosendatestmessagetotheconfiguredsyslogserver. ThisbuttonisavailableonlywheniLORemoteSyslogisenabled. 5.ClickApplytosavethechanges. DisablingiLORemoteSyslog 1.NavigatetotheAdministration→Management→RemoteSyslogpage. 2.CleartheEnableiLORemoteSyslogcheckbox. 3.ClickApplytosavethechanges. Configuringremotesupport HPremotesupportoverview HPhasdevelopedaserviceandsupportsolutionthatintegratesthefollowing: •Anonline,personalizeddashboard(HPInsightOnline) •24x7remotesupportwithHPInsightRemoteSupportsoftwareandInsightOnlinedirect connectcapability WhenyouusetheembeddedRemoteSupportfunctionalitywithanHPProLiantserver,youcan choosefromthefollowingconfigurationoptions: Configuringremotesupport119
Configurationoptions •InsightOnlinedirectconnect—RegisteraservertocommunicatedirectlywithInsightOnline withouttheneedtosetupanInsightRemoteSupportcentralizedHostingDeviceinyourlocal environment.InsightOnlinewillbeyourprimaryinterfaceforremotesupportinformation. InsightOnlineisanHPSupportCenterfeaturethatenablesyoutoviewyourremotelymonitored devicesanywhere,anytime.Itprovidesapersonalizeddashboardforsimplifiedtrackingof IToperationsandsupportinformation,includingamobiledashboardformonitoringwhen youareonthego.Formoreinformation,seehttp://www.hp.com/go/insightonline/info. ForHPProLiantGen8servers,thedirectconnectconfigurationisavailableiniLO41.40and later. ForHPProLiantGen9servers,thedirectconnectconfigurationisavailableiniLO42.00and later. Figure3(page120)showsthedirectconnectconfigurationwithanHPProLiantserver. Figure3InsightOnlinedirectconnect •InsightRemoteSupportcentralconnect—RegisteraservertocommunicatewithHPthrough anInsightRemoteSupportcentralizedHostingDeviceinyourlocalenvironment.All configurationandserviceeventinformationisroutedthroughtheHostingDevice.This informationcanbeviewedusingthelocalInsightRSConsoleortheweb-basedviewinInsight Online(ifitisenabledinInsightRS). ForHPProLiantGen8servers,thecentralconnectconfigurationisavailableiniLO41.10 andlater. ForHPProLiantGen9servers,thecentralconnectconfigurationisavailableiniLO42.00 andlater. Figure4(page120)showsthecentralconnectconfigurationwithanHPProLiantserver. Figure4InsightRemoteSupportcentralconnect 120ConfiguringiLOProLiant serverFirewall ProLiantserverFirewallInsight RS Hosting Device