Speed Dial2-241 Features and Operation Print System Speed Numbers Description The System Speed Numbers command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. Figure 2-17: System Speed Numbers Printout Programming Steps 1. Press the SYSTEM SPEED flexible button (FLASH 85, Button #6). The following message displays: 2. To print the System Speed bins, press the HOLD button. The...
Page 262
2-242Station Attributes Features and Operation Station Attributes Initialize Station Attributes Description The Station Parameters may be initialized setting all data fields to their original, default values. The following data fields are returned to their default value upon initializing the Station Attributes. Table 2-20: Station Attribute Defaults Program CodeFlexible ButtonFeaturesDefault Value (after initialization) FLASH 50/51 PA G E A1 Paging Access Enabled 2Do Not Disturb Enabled 3 Conference...
Page 263
Station Attributes2-243 Features and Operation Programming Steps 1. Press the STATION ATTRIBUTES flexible button (FLASH 80, Button #3). The following message displays: 2. Press the HOLD button. A confirmation tone sounds. FLASH 50/51 PA G E B1 Station Identification 0 (STS 24-Btn Keyset) 6 (SLT w/o MW ) 2 Station Day Class of Service (COS) COS 1 3 Station Night Class of Service (COS) COS 1 4 Speakerphone/Headset Programming 0=Full Speakerphone 5 Pick-Up Group(s) Programming Group 1 6 Paging Zone(s)...
Page 264
2-244Station Attributes Features and Operation Print Station Attributes Description The Print Station Attributes command can be used to print specific flexible station parameters or to print the entire database in fixed number order. The Print Station Attributes command can dump the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. When printing the Station attributes the following data prints:...
Page 265
Station Identification2-245 Features and Operation Programming Steps 1. Press the STATION ATTRIBUTES flexible button (FLASH 85, Button #3). The following message displays: 2. To print data for: All stations, press HOLD. One station, enter the flexible station number, then press HOLD. Then the following message displays and the requested information prints: When the system finishes sending the requested information to the printer, a confirmation tone sounds. Station Identification Description Each...
Page 266
2-246Station Identification Features and Operation 2. Enter the range of fixed station numbers (100-149) to be programmed. If only one station is being programmed, enter that number twice, e.g., [100 100]. -or- Enter a valid flexible number (100-8999) to be programmed. 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 is lit. The display updates to reflect current programming for Page A: 4. Press button #20. The display updates to reflect current...
Page 267
Station Identification2-247 Features and Operation 7. Press HOLD to save the entry. A confirmation tone sounds and the display updates. DEFAULT … All Key Telephone Boards (DTIB) default to ID 0 (STS 24-Button Digital Telephone), all Single Line Boards (SLIB) default to ID 6. Conditions » Only one station at a time can be programmed when using a flexible station number. » When in Flash 51 programming, if you press HOLD without specifying a flexible number to be programmed, you will get the station that...
Page 268
2-248 St a tio n Me ssa g e De ta il Rec o rd i n g Features and Operation Station Message Detail Recording Description The STS station message detail recording (SMDR) provides details on both incoming and outgoing calls. This feature is programmable to allow recording of all calls or just outgoing long distance calls. The system tracks calls by outside line, number dialed, time-of-day, date, station that placed the call and duration of call. Account codes may also be entered and recorded. The SMDR...
Page 269
Station Message Detail Recording 2-249 Features and Operation Figure 2-19: SMDR Printout 80 character format - Outbound Call to a Dialed Number: 1 234 56 7 8 12345678901234567890123456789012345678901234567890123456789012345678901234567890 AAAA BBB HH:MM:SS HH:MM MM/DD/YY HCCCCCCCCCCCCCCCCCCCCCCCC GGGGGGGGGGGG (CR)(LF) STA CO TOTAL START DATE DIALED 1100 001 00:00:38 13:57 01/15/01 O2956006 80 character format - Outbound Call to an Extension: 1 234 56 7 8...
Page 270
2-250 St a tio n Me ssa g e De ta il Rec o rd i n g Features and Operation The STS system can provide SMDR output to the optional RS-232C connectors on the BKSU. When SMDR is desired, the following system-wide parameters determine how SMDR information is reported. Programming Steps 1. Press FLASH and dial [21]. The following message displays: 2. To program SMDR features, use the flexible button(s) as defined in the following procedures. 3. The ENABLE/DISABLE, TYPE, and PRINT features toggle on and...