SYSTEM PARAMETERS PROGRAMMING
infinitem DVX InDigital Key Telephone System
MISC. SYSTEM PARAMETERS
710.4FLASH RATES (Programmable)
F?ro@amming StepsDescriptionIf the system is in the programming mode,This section describes the procedures and
continue using the program codes. If starting tosteps necessary to program the Flash Rates.program here, enter the programming mode.
Refer to Sec. 700.2, Program Mode Entry (Key
The buttons on the digital terminal are defined
Station)as shown below when entering the...

Page 342

inftniteTM DVK I’Digital Key Telephone System
SYSTEM PARAMETERS PROGRAMMING
FLASH RATES (Cont’d)
B. Incoming Intercom Ringing
Programming Steps
a. Press the INCOMING INTERCOM RINGINGflexible button (Button 
#2). The following
message is shown on the display phone:b. Enter a two-digit value on the dial pad to
correspond to one of the 16 available op-
tions. Refer to flash rate table.c. 
Press the HOLD button to save the entry.
Confirmation tone is heard and the displaywill now update.
C. Call Forward...

Page 343

infinite” DVX I’
SYSTEM PARAMETERS PROGRAMMING
Digital Key Telephone System
MISC. SYSTEM PARAMETERS
710.5ATTENDANT STATION ASSIGN-
MENT
Programming Steps
If Attendant Station(s) are to be changed:a. Press FLASH and dial 
[lo]. The following
message is shown on the display phone:
[,
b. Enter up to three three-digit station num-ber(s) on the dial pad.
c. Press the HOLD button to save the entry.
Confirmation tone is heard and the displaywill now update.
710.6SYSTEM TIME AND DATE
Programming StepsTo set the...

Page 344

infinitem DVX I’
Digital Key Telephone SystemSYSTEM PARAMETERS PROGRAMMING
MISC. SYSTEM PARAMETERS (Cont’d)
710.7PBX DIALING CODES
Programming Steps
If PBX Dialing Codes are to be assigned:a. Press FLASH and dial [ 
121. The following
message is shown on the display phone:b.Enter five two-digit code numbers, one
right after the other, on the dial pad up to
a maximum of ten digits.c. Press the HOLD button to save the entry.
Confirmation tone is heard and the displaywill now update....

Page 345

SYSTEM PARAMETERS PROGRAMMING
MISC. SYSTEM PARAMETERS (Cont’d)710.9RELAY/SENSOR PROGRAMMING
Programming StepsDescriptionIt is necessary to assign a Station ID to the
station port 
used for a Relay/SensorInte@ce Module. Refer to Sec. 730.2, Item
A. Station Identification before proceeding.
If Relays are to be assigned:a. Press FLASH and dial 
[ 141. Relay # 1 (Flex
Button # 1) and Relay/Sensor # 1 (Flex But-ton # 12) 
LEDs will be lit indicating the
system is in the programming mode. The
following message...

Page 346

infhitem DVX I’Digital Key Telephone System
SYSTEM PARAMETERS PROGRAMMlNGRELAY/SENSOR PROGRAMMIN
G (Cont’d)
A.
Programming relay for External
Paging:
Programming Steps
1.Press the appropriate flex button 12 thru
15 to indicate which Relay/Sensor Inter-
face Module is to be programmed.2. Press flex buttons (l-3) to indicate the
desired relay to be programmed.
3.Dial [l] on the dial pad.
4.Enter a one-digit page zone number (l-7)
5.Press the HOLD button to save the entry.Confirmation tone is heard and the...

Page 347

infinite” DVX I’Digital Key Telephone System
SYSTEM PARAMETERS PROGRAMMING
RELAY/SENSOR PROGRAMMING 
(Cont’d)
C.Programming relay for Power Failure
Transfer:
Programming Steps
Description
1.Press the appropriate flex button 12 thru
15 to indicate which Relay/Sensor Inter-face Module is to be programmed.
2.Press flex buttons (l-3) to indicate desired
relay to be programmed.
3.Dial [3] on the dial pad.
4.Press the HOLD button to save the entry.Confirmation tone is heard and the dis-
play will now...

Page 348

infznite” DVX I’
Digital Key Telephone System
SYSTEM PARAMETERS PROGRAMMING
RELAY/SENSOR PROGRAMMING (Cont’d)
D.Programming relay for Loud BeiiControl:
Programming Steps
1.Press the appropriate flex button 12 thru
15 to indicate which Relay/Sensor Inter-
face Module is to be programmed.
2.Press flex buttons (l-3) to indicate desiredrelay to be programmed.
3.Dial [4] on the dial pad.
4.Enter the three-digit station number (loo-
195)
5.Press the HOLD button to save the entry.Confirmation tone is heard and...

Page 349

SYSTEM PARAMETERS PROGRAMMING
infinitem DVX I’Digital Key Telephone System
RELAY/SENSOR PROGRAMMIN
G (Cont’d)
E.Programming relay for CO Line
Control:
Programming Steps
1.Press the appropriate flex button 12 thru
15 to indicate which Relay/Sensor Inter-
face Module is to be programmed.
2.Press flex buttons (l-3) to indicate desired
relay to be programmed.
3.Dial [5] on the dial pad.
4.Enter a two-digit CO Line number (01-48)
5.Press the HOLD button to save the entry.Confirmation tone is heard and the...

Page 350

infrnitem DVX I’Digital Key Telephone System
SYSTEM PARAMETERS PROGRAMMING
RELAY/SENSOR 
PROGRAMMING (Cont’d)
G.Program sensing circuit as a RAN
Sensing (RAN END) circuit:
Programming Steps
1.Press the appropriate flex button 12 thru
15 to indicate which Relay/Sensor Inter-
face Module is to be programmed.
2.Press flex buttons (4-6) to select the sens-
ing circuit to be programmed.
3.Dial [61 on the dial pad.
4.Enter a one-digit RAN Table number (l-8)
the sensing circuit should be associated
to.
5.Press...