Trillium Panther Ii Feature Module Iv System Manual
Here you can view all the pages of manual Trillium Panther Ii Feature Module Iv System Manual. The Trillium manuals for Telephone are available online for free. You can easily download all the documents as PDF.
Page 221
Trillium Standard Piactice ,’ They are: . The Panther 306 Non-Handsfree (NHF) Telephone Set . The Panther’306 Handsfree/ Busy Lamp Field (HF/BLF) Telephone Set l The Panther 612 Standard Telephone Set . The Panther 612 Attendant (HF/BLF) Telephone Set l The Panther 1032 NHF Telephone Set l The Panther 1032 HF Telephone Set l The Panther 2064 NHF Telephone Set l The Panther 2064 HF Telephone Set l The Panther II Display Set (Available only on Panther II) . The Panther II Set (Available only...
Page 222
Pant her II 820/l 032/2064-200 TOP AC Power Cord Ground Terminal AMP Connector 37.6 cm (14.8 inch) 34.5 cm (13.6 inch) I llllIIIlllllIIIIlllllIIIIIIIIIIIIII I 6.9 cm .75 inch) . I I- lllll NIlI II L BOTTOM Figure 2-1 Key Service Unit Dimensions 42.7 cm (16.8 inch) RIGHT Installation and Commissioning Page 3
Page 223
Trillium Standard Practice Ringer Volume Handset Jack 10.7 cm (4.2 inch) 17.8 cm (7 inch) 23.9 cm (9.4 inch) Figure 2-2 Panther Telephone Set Dimensions 3. EQUIPMENT IDENTIFICATION General 3.0 1 The major components of the Panther II systems are identified by a part number normally located on the right-hand side of the KSU and on the bottom of the Panther ) telephone sets. Part Numbers 3.0 2 The part numbers of field-replaceable items are given in Table 3-l(a) and Table 3-l(b)....
Page 224
Panther II 820/1032/2064-200 PANTHER II 1032: 1032 KSU Non Handsfree (NHF) Set Handsfree (HF) Set 1032 DSS/BLF Console PANTHER II 2064: 90-0466 go-0320 go-0421 go-031 2 2064 KSU 2064 Non Handsfree (NHF) Set 2064 Handsfree HF Set 2064 DSS/BLF Console PANTHER II 820: 90-0468 90-0288 go-0225 90-0226 820 KSU 90-0465 ADDITIONAL SETS: 306 NHF Set 306 HF/BLF Set 612 Standard Set 612 Attendant Set (HF/BLF Set) Panther II Display Set Panther II Set (Basic Set) ANCILLARY DEVICES:...
Page 225
Trillium Standard Practice PANTHER 11 306 SETS: Plastic Lens - Set Plastic Lens - BLF Set Designation Card - Set . Pk of IO Designation Card - BLF Set, Pk of 10 Designation Card - Set (French) Pk of 10 Designation Card - BLF Set (French) Pk of 10 Line Key Overlay Line Key Overlay (French) PANTHER II 6 12 SETS: Plastic Lens - Set Plastic Lens - BLF Set Designation Card - Set, Pk of 10 Designation Card - BLF Set, Pk of 10 Designation Card - Set (French) Pk of IO Designatiol’;Card - BLF...
Page 226
Panther II 820/1032/2064-200 4. EQUIPMENT CONFIGURATION 4.0 1 The basic equipment configuration for each Panther II 820 system is one 820 Key Service Unit, and up to 20 Panther telephone sets. The Panther II 1032 system is made up of one 1032 Key Service Unit, and up to 32 Panther telephone sets. The Panther II 2064 requires two Key Service Units and up to 64 Panther telephone sets. The two KSUs making up the Panther II 2064 system are: l a 1032 KSU which acts as the main control centre for the...
Page 227
Trillium Standard Practice Figure 5-l KSU Space Requirements KSU Location 5.0 3 The KSU should be mounted in a location which: l is clean, dry and well ventilated. l provides access to the incoming C.O. lines. l is equipped with a grounded 110 Volt ac electrical outlet. l provides an earth ground (an all metal cold water pipe is ideal) 5.0 4 The position of the KSU in relation to the other equipment must be chosen so as to ensure maximum cable lengths from the Main Distribution Frame (MDF), and...
Page 228
Panther II 820/1032/2064-200 The maximum cable lengths are: l KSU to MDF - should not exceed 25 feet. l KSU to stations should not exceed the following: - 2000 feet using 24 AWG cable Power Supply Requirements 5.05 The power for the Panther II systems must be supplied from a 110 Vat, 15 Amp, mains commercial power supply. It is recommended that the supply be: l wired and fused independently from all other power receptacles. l controlled directly from the circuit breaker and not from a local...
Page 229
Trillium Standard Practice Ground Source x --- m C.O. Line I I ’ Short Circuit u--._ Ring Loop Current Ampmeter (DC) *I I* 41 x = reading in milliamps Measure -_-___________. Current on Ring side of line C.O. Line Tip m Ring _--- -N I ’ Figure 5-2 Ground Verifi’cation Installation Tools and Equipment 5.07 The tools and equipment required to instaN the Panther II systems are shown in Table 5- 1, Installation and Commissioning Page 10
Page 230
Panther II 820/1032/2064-200 TOOLS: Screwdrivers Punch Down Tool Staple Gun EQUIPMENT: APPLICATION: Mounting major components Terminating MDF cables Securing cables Modular Jacks Connecting Stations 50-pin ‘D’ Amp Connector KSU to MDF Cable termination MDF (BIX or 66 Block) Main Distribution Frame Surge Protector Lightning protection at mains ac Ground Wire (12 AWG) Grounding the KSU Modular-to-Modular Cords Equipment interconnection 4-wire Cable (24 AWG) Station wiring Table 5-l...