Page 241
Trillium Standard Practice Line Lead Designation Conductor Color MDF Terminal RJ21 Pin Number 11 Tip White-Blue 1 26 Ring Blue-White 2 1 12 Tip White-Orange 3 27 Ring Orange-White 4 2 13 Tip White-Green 5 28 Ring __ Green-White 6 3 14 Tip White-Brown 7 29 Ring Brown-White a 4 15 Tip White-Slate 9 30 Ring Slate-White 10 5 16 Tip Red-Blue 11 31 Ring Blue-Red 12 6 17 Tip Red-Orange 13 32 Ring Orange-Red 14 7 ia Tip Red-Green 15 33 Ring Green-Red 16 a 19 Tip Red-Brown 17...
Page 242
Panther II 820/1032/2064-200 Station Wiring 6.0 8 The station wiring comprises up to three 25-pair cables (Panther II 820), four 25-pair cables (Panther II 1032) or eight 25-pair cables (Panther II 2064), which connect the KSU to the MDF, along with the number of 4-wire cables required to connect the Panther telephone sets to the MDF. The 25-pair cables are not supplied. Each cable must not exceed 25 feet in length and must be fitted with a 50-pin ‘D’ Amp connector (male) at one end. Install the...
Page 244
Panther II 820/1032/2064-200 Remember that each MDF corresponds to a specific group of stations: MDF 1 for Stations 10 to 17; MDF 2 for Stations 18 to 25; MDF 3 for Stations 26 to 33; MDF 4 for Stations 34 to 41. STATION STATION 25-PAIR MDF CONNECTOR LEAD NUMBERS WIRE COLORS WIRE COLORS TERMINAL PIN FUNCTION MDF MDF MDF MDF 1 2 3 4 10 18 26 34 (G) Green White-Blue 1 26 VT (R) Red Blue-White 2 1 VR (B) Black White-Orange 3 27 DT (Y) Yelbw Orange-White 4 2 DR .._ 11 19 27 35 G White-Green 5...
Page 245
Trillium Standard Practice Rcmcmbcr IIUI each MDF corresponds LO a spcdic group ol’ SUI~IIIS: MDF 9 for Sations 42 to 40: MDF 6 for S!aions 50 10 57: XlDF 7 for Stilions SX IO 65: MDF X for Scltions M tn 73 , -: STAT10 N NUMBERS STATION 25-I’.\1 R hl DF CONNECTOR LEAD WIRE COLORS WIRE: COLORS TE:RMINAL PIN FUNCTION IlDF >lDF \lDF MDF 5 6 7 8 -12 SO 58 66 (C) Green White-Blue 1 26 VT (R) Rut Blue-White 2 1 VR (R) Bhck White-Or.qx 3 27 DT (Y) Yellow Orange- While 3 2 DR 13 51 59 67 G...
Page 246
Panther II 820/1032/2064-200 Panther Telephone Set Installation 6.0 9 Installation of a Panther telephone set simply requires the set to be connected, through the DBU4 (6conductor mod-to-mod cord) supplied with the set, to the previously-installed RJ14C jack. Note: If the ‘Off-Hook Voice Announce’feature is used on the Panther II Display Set, a 6-conductor cable and jack is required for that station. Remember that this feature occupies two station ports; for example, tf Station 12 has ‘Off-Hook...
Page 248
Panther II 820/1032/2064-200 Door Answer Unit Installation 6.10 The Door Answer Unit supports a maximum of two Door Modules. It is connected to the KSU via a 3-pair modular cord, supplied with the Door Answer Unit. One Door Answer Unit can be connected to a Panther II 820 or Panther II 1032 system, while two Door Answer Units can be connected to a Panther II 2064 system. When the Door Answer Unit is incorporated in the Panther II 820 system, C.O. line 8 must not be connected at the KSU. When the...
Page 249
Trillium Standard Practice Desk/Wall Mpunt Unit Figure 6-10 Panther Telephone Set Wall Mounting Figure 6-11 Door Module Installation Installation and Commissioning Page 30
Page 250
Panther II 820/1032/2064-200 Power Fail Transfer Unit Installation 6.13 A Power Fail Transfer unit transfers up to four outside lines to four standard telephone sets (2500 or single line sets) in the event of a power failure at the KSU. A number of Power Fail Transfer units can be cascaded to allow the maximum number of C.O. lines to be switched to the corresponding number of standard telephone sets; i.e., two Power Fail Transfer units would be required to switch the eight C.O. lines of a Panther...