Trillium Standard Practice To MDF stations: 24 Vdc Battery AC Power Backup s _~lllli~lllllllllllllllll~ll 4 0 IIIIIIIIIIIIIIIIIIIIIIIII IIbdhn -18to25 KEY Background Music Music on Hold AmDlifier I Feature Module Cartridge e Power Fail Station M:yge I rl . Answer Door Unit Module Dl 02 DA Incoming - $%xBW Lines (1 -8) !53 Printer / Terminal Figure 6-l (a) Panther II 820 Main Configuration Installation and Commissioning Page 12
Page 232
Panther II 820/1032/2064-200 A a T 24 Vdc Battery AC Power Backup To MDF stations: Back round Music Music on Hold I Feature Module Cartridge II Door III III Station MreTtt Recorder Connect to Panther 2064 Cabinet or connect to 6 C.O. Line Module, if applicable I Incoming C.O./PBW Centrex Lines (1 - 10) II I I 557 To Printer/Terminal Figure 6-l(b) Panther II 1032 Main Configuration Installation and Commissioning Page 13
Page 233
Trillium Standard Practice To MDF stations: AC Pnwer 24 Vdc Battery L’ I Backup , ._ . __._. I ~lllllllllllllllllllli L KEY SEURNL;FE Power Fail Connect to Panther 1032 Cabinet 1 I= -ill Incoming C.O./PBX/ Centrex Lines (11 -20) Figure 6-l(c) Panther II 2064 Main Configuration Installation and Commissioning Page 14
Page 234
Panther II 820/1032/2064-200 Mounting System Components 6.0 4 The following instructions detail the installation of the KSU. The installation procedure is similar for any ancillary devices included in the system, only the location of the mounting screws may differ. This can be seen in Figures 6-2 to 6-6. Step 1. Using suitable fasteners, mount a wooden backboard, of sufficient size to accommodate the KSU and ancillaq devices (if any), to the wall, within 4 feet of the ac outlet and at least 12...
Page 236
Panther II 820/1032/2064-200 t 17.8 cm (7 inch) 14.9 cm (5.875 inch) Wooden Backboard Door / Answer Unit Figure 6-3 Door Answer Unit Wall Mounting Installation and Commissioning Page 17
Page 237
Trillium Standard Practice --. 7.9 cm (3.125 inch) -1 Wooden 8.9 cm (3.5 inch) Power Fail Transfer Unit Figure 6-4 Power Fail Transfer Unit Wall Mounting Installation and Commissioning Page 18
Page 238
Panther II 820/1032/2064-200 7.9 cm ( 3.11 inch) r-7 Wooden t n 1- -. -. . . -. Station Message Detail Recording Unit J Ull (3.56 inch) Figure 6 -5 SMDR Unit Wall Mounting Connect The Equipment To Ground 6.0 6 The KSU must be connected to ground through a single solid conductor. Caution: DO NOT rely on the third wire (Green) of the AC cord to connect the KSU to ground. A separate external ground lead must be connected. Installation and Commissioning Page 19
Page 240
Panther II 820/1032/2064-200 Step 2. When the system comprises a 2064 KSU, repeat Step 1 for CO. lines 11 through 20. When a second Door Answering Unit forms part of the system configuration, do not connect C.O. line 20. Line Lead Designation Conductor Color MDF Terminal RJ21 Pin Number 1 Tip White-Blue 1 26 Ring Blue-White 2 1 2 Tip White-Orange 3 27 Ring Orange-White 4 2 3 Tip White-Green 5 28 Ring Green-White 6 3 4 Tip White-Brown 7 29 Ring Brown-White 8 4 5 Tip White-Slate 9 30 Ring...