Page 181
CHAPTER 9 TRUNK DATA 1. Trunk Group Data Block (Table 9-1) 1.01 The Trunk Group Data Block (DTGP Pro- gram) defines the parameters for each of the 16 possible trunk groups in the system. A Data Block must be completed for each trunk group in the system. Not all of the prompts listed below are used for all trunk types. The response given to the TKT (trunk type) prompt will determine which prompts will be given. Table g-la shows the prompts that can be expected for each trunk type. (Use the...
Page 182
PROGRAMMINGPROCEDURES SECTION 200-255-309 FEBRUARY1992 COD (Access Code)-Defines the access code for the trunk group. Access codes can consist of 1, 2, or 3 digits as long as there is no conflict in the system. For example: 3 cannot be used if 30 or 300 is used as an access code or DN. Enter: 1 - 3 digits. COS (Class of Service)-Defines the feature access level of each inward dialing trunk (TIE, DID, or CCSA trunk). Use one of the 16 Classes of Service that has been defined via the DCOS...
Page 183
PROGRAMMINGPROCEDURES SECTION 200-255-309 FEBRUARY1992 TOL (Toll Restriction Class)-Assigns one of the IO classes of Toil Restriction to each outgoing TIE, CCSA, and DID trunk. Classes 0 - 7 are defined in the Toll Restriction Data Block (DTOL Program). Class 8 is simple Toll Restriction and restricts when either 1 or n is dialed as the first digit. NONE defines the trunk as unrestricted. Enter: 0 - 8 or NONE. FLT (Flash-hook Timing)-Defines the length of time of a flash-hook (line open)...
Page 184
PROGRAMMING PROCEDURES SECTION 200-255-309 FEBRUARY 1992 TABLE 9-l Procedure - Trunk Group Data Block Authorization Procedure must be completed. If an OK response is received, proceed as follows: NOTES: (continued) I. A maximum of 7 6 Trunk’Groups (normally 00 - 75) is possible. If priva te lines are to be equipped, the code PVL is used in place of 15. 2. TKT cannot be changed. The Data Block must be removed (OUT) and NEW data must be entered. The “DNIS” prompt will appear only when one of...
Page 185
PROGRAMMING PROCEDURES SECTION 200-255-309 FEBRUARY 1992 TABLE 9- -la TRUNK GROUP DATA I BLOCK ENTRIES TRUNK TYPES COT FEX WAT PVL DID CSA TIE GRP X X X X X X X TEN X X X X X X X ITKT I x I x I x I x I x I x I x I DNIS 0 0 0 0 X X X DIG 0 0 0 0 X X X IA0 X X X X X X X STP X X X 0 X X X COD X X X 0 X X X cos 0 0 0 0 x x x TRN X X X X X X X STR X X X X X X X WTA X X X X X X X IAB 0 0 0 0 X X X TRNl 0 0 0 0 X X X ITRNPI 0 I 0 1 0 1 0 1 X 1 X I X 1 TOL 0 0 0 0 0 X X FLT X X X X 0 0...
Page 186
PROGRAMMINGPROCEDURES SECTION ZOO-255309 FEBRUARY1992 TABLEg-lb PERCEPTION,LOSSPLAN THROUGH CONNECTION TERMINAL BALANCE THROUGH BALANC NON-VNL VNL Transmission Non-transmission Compensated . Station Lines/ Compensated (2-wire facility (2-wire facility >2dB loss or 4 wire Attendant Lines 2dB loss or impedance compensated or 4-wire facility) g$ gsg 4 wire lx-‘> Id cm 5 1 1 3 1 3 1 3 1 1 1 1 3 3 1 1 /VOTE: The numbers in the boxes represent actual through connection loss in dB. 9-6
Page 187
PROGRAMMINGPROCEDURES SECTION 200-255-309 FEBRUARY1992 TABLE 9-2 Procedure - Print Trunk Group Data Block Authorization Procedure must be completed. If an OK response is received, proceed as follows: ITEM PROMPT USER ENTRY NOTE OK PTGP - DISK LOADING - REQ 1 - EXECUTE - NOTES: 1. The following responses are possible: ALL = Outputs all Trunk Group Data Blocks. GRPXX = Outputs Trunk Group XX Data Blocks. COT = Outputs all CO Trunk Group Data Blocks. FEX = Outputs all FX Trunk Group Data...
Page 188
PROGRAMMINGPROCEDURES SECTION 200-255-309 FEBRUARY1992 3. Trunk Data Block (Table 9-3) 3.01 The Trunk Data Block (DTRK Program) de- fines the parameters for each of the trunk circuits in the system. A separate Data Block must be com- pleted for each trunk circuit in the system. NOTE: When using the NDTU PC6 (Digital T-l inter- face) Trunk Data Block programming remains the same. Each T-l channel (24 per each NDTU PCB) equals a trunk circuit. 3.02 The trunk type (TKT) defined for the group...
Page 189
better enables the receiver to handle the call. Trunk Name also appears on outgoing calls. Enter: Trunk name (A - Z, 0 - 9, [space]), NONE. NOTE: The maximum number of alphanumeric char- acters a//owed for a trunk name is 16. TDN (Trunk Directory Number)-For private lines only (Trunk Group 15-PVL). TDN defines a directory number that will be used to assign private lines to a station. Enter: 1 - - 3-digit directory number. RAD (Remote Access Day)-A “Y” response en- ables the Remote Access to...
Page 190
PROGRAMMING PROCEDURES SECTION 200-255-309 FEBRUARY 1992 CTL (Control of Disconnect)-Defines the re- lease control of TIE, DID, or CCSA connection. Enter: OPC (Originating Party Control)-The circuit will not be released until the trunk that originated the call disconnects. FPR (First Party Release)-The trunk at either end of the connection can release. DIN (incoming Dialing)-Informs the system of what type of dialing to expect on an incoming call. (This prompt is for TIE, CCSA, and DID...