CHAPTER 9 
TRUNK DATA 
1. Trunk Group Data Block (Table 9-1) 
1.01 The Trunk Group Data Block (DTGP Pro- 
gram) defines the parameters for each of the 16 
possible trunk groups in the system. A Data Block 
must be completed for each trunk group in the 
system. Not all of the prompts listed below are used 
for all trunk types. The response given to the TKT 
(trunk type) prompt will determine which prompts 
will be given. Table g-la shows the prompts that 
can be expected for each trunk type. (Use the...

Page 182

PROGRAMMINGPROCEDURES 
SECTION 200-255-309 
FEBRUARY1992 
COD (Access 
Code)-Defines the access code 
for the trunk group. Access codes can consist of 
1, 2, or 3 digits as long as there is no conflict in 
the system. For example: 3 cannot be used if 30 
or 300 is used as an access code or DN. 
Enter: 1 - 3 digits. 
COS 
(Class of Service)-Defines the feature access 
level of each inward dialing trunk (TIE, DID, or CCSA 
trunk). Use one of the 16 Classes of Service that has 
been defined via the DCOS...

Page 183

PROGRAMMINGPROCEDURES 
SECTION 200-255-309 
FEBRUARY1992 
TOL (Toll Restriction Class)-Assigns one of the 
IO classes of Toil Restriction to each outgoing 
TIE, CCSA, and DID trunk. Classes 0 - 7 are 
defined in the Toll Restriction Data Block (DTOL 
Program). Class 8 is simple Toll Restriction and 
restricts when either 1 or n is dialed as the first 
digit. NONE defines the trunk as unrestricted. 
Enter: 0 - 8 or NONE. 
FLT (Flash-hook Timing)-Defines the length of 
time of a flash-hook (line open)...

Page 184

PROGRAMMING PROCEDURES 
SECTION 200-255-309 
FEBRUARY 1992 
TABLE 9-l 
Procedure - Trunk Group Data Block 
Authorization Procedure must be completed. If an OK response is received, proceed as follows: 
NOTES: (continued) 
I. A maximum of 7 6 Trunk’Groups (normally 00 - 75) is possible. If priva te lines are to be equipped, the code 
PVL is used in place of 15. 
2. TKT cannot be changed. The Data Block must be removed (OUT) and NEW data must be entered. The 
“DNIS” prompt will appear only when one of...

Page 185

PROGRAMMING PROCEDURES 
SECTION 200-255-309 
FEBRUARY 1992 
TABLE 9- -la 
TRUNK GROUP DATA I 
BLOCK ENTRIES 
TRUNK TYPES 
COT FEX WAT PVL DID CSA TIE 
GRP X X X X X X X 
TEN X X X X X X X 
ITKT I x I x I x I x I x I x 
I x I 
DNIS 0 
0 0 0 X 
X X 
DIG 0 0 0 0 X X X 
IA0 X X X X X X X 
STP X X X 0 X X X 
COD X X X 0 X X X 
cos 0 0 0 0 x x x 
TRN X X X X X X X 
STR X X X X X X X 
WTA X X X X X X X 
IAB 0 0 0 0 X X X 
TRNl 0 0 0 0 X X X 
ITRNPI 0 I 0 1 0 1 0 1 X 1 X I X 1 
TOL 0 0 0 0 0 X X 
FLT X X X X 0 0...

Page 186

PROGRAMMINGPROCEDURES 
SECTION ZOO-255309 
FEBRUARY1992 
TABLEg-lb 
PERCEPTION,LOSSPLAN 
THROUGH CONNECTION TERMINAL BALANCE 
THROUGH BALANC 
NON-VNL 
VNL 
Transmission 
Non-transmission Compensated 
. 
Station Lines/ Compensated (2-wire facility 
(2-wire facility >2dB loss or 4 wire 
Attendant Lines 2dB loss 
or impedance compensated 
or 4-wire facility) 
g$ 
gsg 4 wire 
lx-‘> 
Id 
cm 5 1 1 3 
1 3 1 3 
1 1 1 1 
3 3 1 1 
/VOTE: 
The numbers in the boxes represent actual through connection loss in dB. 
9-6  

Page 187

PROGRAMMINGPROCEDURES 
SECTION 200-255-309 
FEBRUARY1992 
TABLE 9-2 
Procedure 
- Print Trunk Group Data Block 
Authorization Procedure must be completed. If an 
OK response is received, proceed as follows: 
ITEM PROMPT USER ENTRY NOTE 
OK PTGP 
- DISK LOADING - 
REQ 1 
- EXECUTE - 
NOTES: 
1. The following responses are possible: 
ALL = Outputs all Trunk Group Data Blocks. 
GRPXX = Outputs Trunk Group XX Data Blocks. 
COT = Outputs all CO Trunk Group Data Blocks. 
FEX = Outputs all FX Trunk Group Data...

Page 188

PROGRAMMINGPROCEDURES 
SECTION 200-255-309 
FEBRUARY1992 
3. Trunk Data Block (Table 9-3) 
3.01 The Trunk Data Block (DTRK Program) de- 
fines the parameters for each of the trunk circuits in 
the system. A separate Data Block must be com- 
pleted for each trunk circuit in the system. 
NOTE: 
When using the NDTU PC6 (Digital T-l inter- 
face) Trunk Data Block programming remains 
the same. Each T-l channel (24 per each 
NDTU PCB) equals a trunk circuit. 
3.02 The trunk type (TKT) defined for the group...

Page 189

better enables the receiver to handle the call. 
Trunk Name also appears on outgoing calls. 
Enter: Trunk name (A - Z, 0 - 9, [space]), 
NONE. 
NOTE: 
The maximum number of alphanumeric char- 
acters a//owed for a trunk name is 16. 
TDN (Trunk Directory Number)-For private lines 
only (Trunk Group 15-PVL). TDN defines a 
directory number that will be used to assign 
private lines to a station. 
Enter: 1 - - 3-digit directory number. 
RAD (Remote Access Day)-A “Y” response en- 
ables the Remote Access to...

Page 190

PROGRAMMING PROCEDURES 
SECTION 200-255-309 
FEBRUARY 1992 
CTL (Control 
of Disconnect)-Defines the re- 
lease control of TIE, DID, or CCSA connection. 
Enter: OPC (Originating Party Control)-The 
circuit will not be released until the trunk 
that originated the call disconnects. 
FPR (First Party Release)-The trunk 
at either end of the connection can 
release. 
DIN (incoming Dialing)-Informs the system of 
what type of dialing to expect on an incoming 
call. (This prompt is for TIE, CCSA, and DID...