Page 131

PROGRAMMINGPROCEDURES 
SECTION 200-255-305 
FEBRUARY1992 
TABLE 5-2(continued) 
ITEM 
PROMPT USER ENTRY NOTE 
Attendant Overflow Timeout AOF 0 - 255 seconds (30) 7 
Call Forward No Answer Timeout CFD 0 - 255 seconds (10) 8 
2500 Hold/Electronic/Digital Telephone Park 
Timeout I HLD 
I 0 - 255 seconds or NONE (50) 
I 
Dial Pause Timeout 
I DPT 
1 0 - 255 seconds (15) 
I 9 
Pushbutton Timeout 
Line Lockout Timeout 
Automatic Callback Reserve Time PBT 
LLO 
ACB 0 - 255 seconds (4) 
0 - 255 seconds (15) 
0 -...

Page 132

PROGRAMMING PROCEDURES 
SECTION 200-255-305 
FEBRUARY 1992 
TABLE 5-2 (continued) 
Error Codes 
Program Name: System Data Block (DSYS Program) 
Error Code 
I Meaning 
ERSYS 00 The directory number or access code conflicts with an existing 
directory number, access code, or room prefix. 
ERSYS 01 
I The entered DN does not exist in the system. 
ERSYS 02 -entered DN is a trunk DN. 
ERSYS 05 1 The station DN has not been assigned as a remote access DN. 
The entered station port is not assigned, or is not a...

Page 133

4. System Data Block 2 (Table 5-4) 
4.01 The System Data Block (DSDZ Program) 
contains miscellaneous data entries that apply to 
the system as a whole rather than to any individual 
station or trunk. Data is entered as follows: 
REQ (Request)-Indicates that the program has 
loaded. Since data is always present, only the 
CHG response is possible. 
MD0 (Master DNO)-Assigns a “master number’ 
to Distributed Hunt Group 0. Whenever this 
number is dialed, the calls will be distributed 
among the stations in...

Page 134

PROGRAMMINGPROCEDURES 
SECTION 200-255-305 
FEBRUARY1992 
(LNNX denotes the station port number 
of the electronic telephone that is to be 
assigned as an attendant position. Up to 
eight port numbers may be entered in 
any one line.) 
PEX (PERCEPTIONex Indication)-Designates 
whether the system being utilized is a PERCEP- 
TIONex. 
Enter: Y or N. 
CDA (Call Distribution Algorithm)-Offers two 
algorithms that the system can choose to process 
incoming calls that are in queue. The two algo- 
rithms...

Page 135

PROGRAMMINGPROCEDURES 
SECTION 200-255-305 
FEBRUARY1992 
TABLE 5-4 
Procedure - System Data Block 2 
Authorization Procedure must be completed. If an OK response is received, proceed as follows: 
ITEM 
PROMPT USER ENTRY NOTE 
OK 
DSD2 
- DISK LOADING - 
REQ 1 CH& 
I 
Master DNO #0 
MD0 1 - 4 Digits (NONE) 1 
Master DNl #I MD1 1 - 4 Digits (NONE) 1 
Master DN2 #2 
MD2 1 - 4 Digits (NONE) 1 
Master DN3 #3 
MD3 1 - 4 Digits (NONE) 1 
Lodging/Health Care AHM 
Y or N (N) 2 
Night Operator Station 
NOS XXXX...

Page 136

PROGRAMMING PROCEDURES 
SECTION 200-255-305 
FEBRUARY 1992 
I 1. NAF = Next Available First. M/F = Most Idle First. 
72. The digit 7, 2,3,4, or NONE. /fan M/S machine is connected, only I- or2-digit code length, or NONE 
may be entered. 
13. Y = The system is connected to the M/S machine. N = The system is not connected to the MIS 
machine. 
14. Y= The ACDagentpositionisinauto-answermode (EfWDKTfeature ONLY). N= The ACDagent 
position is not in auto-answer mode. 
15. The digit 1, 2, 3, or 4 representing...

Page 137

PROGRAMMING PROCEDURES 
SECTION 200-255-305 
FEBRUARY 1992 
Enter: PRT. 
5. Print System Data Block 2 (Table 5-5) 
5.01 To use the Print System Data Block 2 (PSYS 
Program): 
l Perform the Authorization Procedure (Level 1,2, 
or 3). 
Enter: PSY2 (in response to the OK prompt). 
l When the REQ prompt is received after the 
program is loaded: 
l The System Data Block 2 will be output in the 
same format as it was input in the DSDP Pro- 
gram. 
l REQ will be prompted again once the printout is 
complete....

Page 138

PROGRAMMINGPROCEDURES 
SECTION 200-255-306 
JANUARY1993 
CHAPTER 6 
FEATURE DATA 
1. Access Code Data Block (Table 6-1) 
1.01 The Access Code Data Block (DACD Pro- 
gram) assigns the dial access codes for feature 
execution. Data is entered as follows: 
REQ (Request)--indicates that the program has 
loaded. Since data is always present, only the 
CHG response is possible. FTR (Feature)- 
Enter: The 3- or 4-character feature abbrevia- 
tion (see Table 6-1 a), a space, and then 
the desired 1 - 3 digit...

Page 139

PROGRAMMINGPROCEDURES 
SECTION 200-255-306 
JANUARY1993 
TABLE64a 
FEATUREABBREVIATIONANDCODELIST 
(con tirtued) 
6-2  

Page 140

PROGRAMMINGPROCEDURES 
SECTlON200-255-306 
FEBRUARY1992 
TABLE 6-la (continued) 
FEATURE 
Speed Dial-Station - Call 
Speed Dial-Station - Program 
Speed Dial-System - Call 
Universal Night Answer 
Charge Account (ACL in DMDR must be set) 
Flash 
Internal Group Paging (selected group 1, 2 - 17) 
Expanded Internal Group Paging (group 0) 
External Paging (selected zone 0 - 4) 
External All Paging (zones 0 - 4) 
Hold - All Calls Retrieve 
Message Waiting All Clear 
Message Waiting Cancel 
Do Not Disturb 
Do...