Page 161

PROGRAMMINGPROCEDURES 
SECTION 200-255-307 
JANUARY1993 
list number XX. 
(XX = 1 - 50.) 
NONE-No list assigned. 
WTA (Warning Tone Allowed?)-Defines an in- 
terruption-protected station. An “N” response 
will prevent warning tones from being applied to 
the station. 
Enter: Y or N. 
CFT (Call Forward to Trunk)-Permits calls to 
this station to be forwarded over a trunk to an 
outside directory number (maximum: 16 digits). 
Enter: Y or N. 
TOL (Toll Restriction Class)-Assigns one of the 
ten Toll...

Page 162

TABLE 7-3 
Procedure - Standard Telephone Data Block PROGRAMMINGPROCEDURES 
SECTION 200-255-307 
JANUARY1993 
Authorization Procedure must be completed. If an OK response is received, proceed as follows: 
ITEM PROMPT 
USER ENTRY NOTE 
OK DS-IT 
JY-IAl, 
Port Number - DISK LOADING - 
-Q NEW, CHG, OUT 
POR LNNX l&2 
Directory Number 
I 
DN 1 - 4 digits 
I 3 I 
Station Mix 
SMX Y or N 
Class of Service cos o- 15 4 
Tenant Number 
TEN 0 or 1 5 
Call Pickup Group 
PUG 0 - 31 or NONE 6 
Hunt number 
Dialing...

Page 163

PROGRAMMING PROCEDURES 
SECTION 200-255-307 
JANUARY 1993 
Classes 0 - 7 are defined in the Toll Restriction Data Block 
Class 8 = Dia/m or 0 restriction. 
NONE = No Toll Restriction. 
Ignore line entered. 
Backspace. 
Stop printing and return to REQ. 
Exit program. 
TABLE 7-3 (continued) 
Error Codes 
(DTOL Program). 
Error Code 1 Program Name: Standard Telephone Data block (DSlT) 
Meanina 
ERSTA 00 No PCB is equipped at that location. 
ERSTA 01 
The PCB is an NEKU type (not an NSTU). 
ERSTA 02 Port is...

Page 164

4. Print Station Data Block (Table 7-4) 
4.01 
To use the Print Station Data Block (PSDB 
Program): 
l Perform the Authorization Procedure (Level 1,2, 
or 3). 
Enter: PSDB (in response to the OK prompt). 
l After the program is loaded and the REQ prompt 
is received, enter one of the following com- 
mands: 
PORALL-All Electronic/Digital Telephone and 
Standard Telephone Data Blocks will be output 
in numerical order of port numbers (lowest 
number first). 
PORNNX-The Data Block for port NNX will be...

Page 165

PROGRAMMING PROCEDURES 
SECTION 200-255-307 
FEBRUARY 1992 
TABLE 7-4 (continued) 
Error Codes 
Program Name: Print Station Data Block (PSDB) 
Error Code 1 Meaning 
ERPST 00 
ERPST 01 The input PCB number or circuit number is out of range. 
The inout DN does not exist. 
1 ERPST 02 1 The input port is not assigned to an electronic or a 500/2500-series telephone. 
ERPST 03 
ERPST 04 A manual signaling port does not exist. 
The input DN is not assigned to an electronic/digital telephone or to a...

Page 166

5. Print Call Pickup Groups (Table 7-5) 
5.01 To use the Print Call Pickup Groups (PCPG 
Program): 
l Perform the Authorization Procedure (Level 1,2, 
or 3). 
Enter: PCPG (in response to the OK prompt). 
l After the program is loaded and an REQ prompt 
is received, enter one of the following com- 
mands: 
ALL-All Call Pickup groups will be output. 
PROGRAMMINGPROCEDURES 
SECTION 200-255-307 
FEBRUARY1992 
DNXXXX-The number of the Call Pickup group 
containing DNXXXX will be output. 
Example: 
#l REQ...

Page 167

PROGRAMMING PROCEDURES 
SECTION 200-255-307 
FEBRUARY 1992 
6. Print Hunting Arrangements (Table 7-6) 
6.01 To use the Print Hunting Arrangements (PHNT 
Program): 
l Perform the Authorization Procedure (Level 1,2, 
or 3). 
Enter: PHNT (in response to the OK prompt). 
l When an REQ prompt is received after the 
program is loaded, enter the following com- 
mand: ALL-All hunting sequences will be output. 
l The output format will be as in the following 
examples: 
REQ ALL 
HNT 223-224-225 
HNT 242-243 
HNT...

Page 168

7. Print Paging Group Data Block (Table 7-7) 
7.01 
To use the Print Paging Group Data Block 
(PPAG Program): 
l Perform the Authorization Procedure (Level 1,2, 
or 3). 
Enter: PPAG (in response to the OK prompt). 
l After the program has loaded and the REQ 
prompt has been received, enter one of the 
following commands: 
PROGRAMMING PROCEDURES 
SECTION 200-255-307 
FEBRUARY 1992 
PAG 
N-All electronic/digital telephone ports be- 
longing to the indicated paging group N will be 
output in the order in...

Page 169

PROGRAMMING PROCEDURES 
SECTION 200-255-307 
FEBRUARY 1992 
8. DSS Console Data Block (Table 7-8) 
8.01 
The DSS Console Data Block (DDSS Pro- 
gram) 
is used to assign both electronic and digital 
DSS consoles. A maximum of eight electronic/digital 
DSS consoles can be assigned. Each DSS console 
must be assigned to an electronic/digital telephone 
and up to two consoles may be assigned to each 
electronic/digital telephone. Each console has 60 
programmable buttons, which may be programmed 
as either...

Page 170

PROGRAMMING PROCEDURES 
SECTION 200-255-307 
FEBRUARY 1992 
operation), or to a specific feature. When 
assigning or deleting data from DSS console 
buttons, data can be assigned/deleted in groups. 
Additionally, data that is assigned to one DSS 
console may be duplicated either entirely or 
partially (either specific buttons or columns of 
buttons) onto another DSS console by using 
range programming functions. To program a 
DSS console button, perform oneof the following 
operations: 
--., 1) Assign a...
Start reading Toshiba Perception E Ex Digital Pbx Installation And Maintenance Manual

Related Manuals for Toshiba Perception E Ex Digital Pbx Installation And Maintenance Manual

All Toshiba manuals