Page 161
PROGRAMMINGPROCEDURES SECTION 200-255-307 JANUARY1993 list number XX. (XX = 1 - 50.) NONE-No list assigned. WTA (Warning Tone Allowed?)-Defines an in- terruption-protected station. An “N” response will prevent warning tones from being applied to the station. Enter: Y or N. CFT (Call Forward to Trunk)-Permits calls to this station to be forwarded over a trunk to an outside directory number (maximum: 16 digits). Enter: Y or N. TOL (Toll Restriction Class)-Assigns one of the ten Toll...
Page 162
TABLE 7-3 Procedure - Standard Telephone Data Block PROGRAMMINGPROCEDURES SECTION 200-255-307 JANUARY1993 Authorization Procedure must be completed. If an OK response is received, proceed as follows: ITEM PROMPT USER ENTRY NOTE OK DS-IT JY-IAl, Port Number - DISK LOADING - -Q NEW, CHG, OUT POR LNNX l&2 Directory Number I DN 1 - 4 digits I 3 I Station Mix SMX Y or N Class of Service cos o- 15 4 Tenant Number TEN 0 or 1 5 Call Pickup Group PUG 0 - 31 or NONE 6 Hunt number Dialing...
Page 163
PROGRAMMING PROCEDURES SECTION 200-255-307 JANUARY 1993 Classes 0 - 7 are defined in the Toll Restriction Data Block Class 8 = Dia/m or 0 restriction. NONE = No Toll Restriction. Ignore line entered. Backspace. Stop printing and return to REQ. Exit program. TABLE 7-3 (continued) Error Codes (DTOL Program). Error Code 1 Program Name: Standard Telephone Data block (DSlT) Meanina ERSTA 00 No PCB is equipped at that location. ERSTA 01 The PCB is an NEKU type (not an NSTU). ERSTA 02 Port is...
Page 164
4. Print Station Data Block (Table 7-4) 4.01 To use the Print Station Data Block (PSDB Program): l Perform the Authorization Procedure (Level 1,2, or 3). Enter: PSDB (in response to the OK prompt). l After the program is loaded and the REQ prompt is received, enter one of the following com- mands: PORALL-All Electronic/Digital Telephone and Standard Telephone Data Blocks will be output in numerical order of port numbers (lowest number first). PORNNX-The Data Block for port NNX will be...
Page 165
PROGRAMMING PROCEDURES SECTION 200-255-307 FEBRUARY 1992 TABLE 7-4 (continued) Error Codes Program Name: Print Station Data Block (PSDB) Error Code 1 Meaning ERPST 00 ERPST 01 The input PCB number or circuit number is out of range. The inout DN does not exist. 1 ERPST 02 1 The input port is not assigned to an electronic or a 500/2500-series telephone. ERPST 03 ERPST 04 A manual signaling port does not exist. The input DN is not assigned to an electronic/digital telephone or to a...
Page 166
5. Print Call Pickup Groups (Table 7-5) 5.01 To use the Print Call Pickup Groups (PCPG Program): l Perform the Authorization Procedure (Level 1,2, or 3). Enter: PCPG (in response to the OK prompt). l After the program is loaded and an REQ prompt is received, enter one of the following com- mands: ALL-All Call Pickup groups will be output. PROGRAMMINGPROCEDURES SECTION 200-255-307 FEBRUARY1992 DNXXXX-The number of the Call Pickup group containing DNXXXX will be output. Example: #l REQ...
Page 167
PROGRAMMING PROCEDURES SECTION 200-255-307 FEBRUARY 1992 6. Print Hunting Arrangements (Table 7-6) 6.01 To use the Print Hunting Arrangements (PHNT Program): l Perform the Authorization Procedure (Level 1,2, or 3). Enter: PHNT (in response to the OK prompt). l When an REQ prompt is received after the program is loaded, enter the following com- mand: ALL-All hunting sequences will be output. l The output format will be as in the following examples: REQ ALL HNT 223-224-225 HNT 242-243 HNT...
Page 168
7. Print Paging Group Data Block (Table 7-7) 7.01 To use the Print Paging Group Data Block (PPAG Program): l Perform the Authorization Procedure (Level 1,2, or 3). Enter: PPAG (in response to the OK prompt). l After the program has loaded and the REQ prompt has been received, enter one of the following commands: PROGRAMMING PROCEDURES SECTION 200-255-307 FEBRUARY 1992 PAG N-All electronic/digital telephone ports be- longing to the indicated paging group N will be output in the order in...
Page 169
PROGRAMMING PROCEDURES SECTION 200-255-307 FEBRUARY 1992 8. DSS Console Data Block (Table 7-8) 8.01 The DSS Console Data Block (DDSS Pro- gram) is used to assign both electronic and digital DSS consoles. A maximum of eight electronic/digital DSS consoles can be assigned. Each DSS console must be assigned to an electronic/digital telephone and up to two consoles may be assigned to each electronic/digital telephone. Each console has 60 programmable buttons, which may be programmed as either...
Page 170
PROGRAMMING PROCEDURES SECTION 200-255-307 FEBRUARY 1992 operation), or to a specific feature. When assigning or deleting data from DSS console buttons, data can be assigned/deleted in groups. Additionally, data that is assigned to one DSS console may be duplicated either entirely or partially (either specific buttons or columns of buttons) onto another DSS console by using range programming functions. To program a DSS console button, perform oneof the following operations: --., 1) Assign a...