E- EXTENSIONS
EA- UCD GROUP MASTER EXTENSION NUMBER
l
l
l
l
l
P
Feature ReferenceE- Extensions, 
 Hunt Type  Enter a hunt type for each member of the
hunting group and the master extension number. The choices are:
00 Extension not in a hunt group
04 UCD hunting with no overflow and no group busy voice message
05 UCD hunting with overflow and no group busy voice message
06 UCD hunting with overflow and group busy voice message
 Reset Queues  Reset the system queues after initial UCD
programming.
Voice...

Page 372

E- EXTENSIONS
EA- UCD GROUP MASTER EXTENSION NUMBER
Instructions
Step 1 
Step 1 l
Step 2 
Step 3 l
To enter data on the PRF:
Enter the master extension number for each extension on Table 3. To have no
master, enter 300.
For attendants. enter  This is for reference only.
To enter data at the programming terminal:
Type 
EA. You see:  300
Press RETURN to program extension 
OR
Enter another extension number and press RETURN. In either case, you see:
UCD MASTER 
Enter data for this option from Table 3 and...

Page 373

E- EXTENSIONS
EB- PERSONAL SPEED 
 BLOCK
Description
Note:
Use this option to assign a Speed Dial block to an extension for Extension
Speed Dial. You can assign only one block to an extension, but more than
one extension can share the same block. This lets the users share Extension
Speed Dial numbers. Do not, however, assign an extension one of the System
Speed Dial blocks.
When assigning blocks. you normally assign the highest available block to the
lowest extension number. For example, extension 300...

Page 374

E- EXTENSIONS
EB- PERSONAL SPEED DIAL BLOCK
Description
(Cont’d)
Related
Programming
Feature Reference
Instructions
Step 1 
Step 1 
Step  
Step 3 
Default Assignments for VS (with 3-digit System Speed Dial):
Extension Block
300......
301......
302......
303...... assigned
304......
through
347......
 2
Blocks  are for System Speed Dial. Blocks 53-57 are unassigned.
Speed Dial
CP- Inhibit System Speed Dial 
  Allow/deny extensions with this
COS the ability to use System Speed Dial numbers.
E- Extensions,...

Page 375

E- EXTENSIONS
EC- GROUP CALL PICKUP GROUP
Description
Related
Programming
Feature Reference
Instructions
Step  
Step  l
Step  
Step 3 l
Issue 1-O
Use this option to assign an extension to a Call Pickup Group (01-23). To
assign a trunk to a Call Pickup Group, refer to EC (Trunks)- Call Pickup
Group.
For DISA and tie trunks. refer to E- Trunks, EC- Group Call Pickup.
Conditions
This option does not apply to DSS Consoles or Modem Pooling ports.
Default 
Extensions not assigned to Call Pickup Groups (00)....

Page 376

E- EXTENSIONS
 -EC- PRIVACY GROUP
Description
Use this option to assign a  to a Privacy Group (01-99).
Conditions
None
Default Value
 not assigned to a  Group (00).
Related
Programming
Feature Reference
Instructions
Step  
Step 1 
Step  
Privacy Groups
KS- Programming Keys for  Privacy Group members 
line keys.
None
Privacy Groups
To enter data on the PRF:
Enter the Privacy Release Group number for each extension on Table 3. T
O
assign no group number, enter 00.
To enter data at the programming...

Page 377

E- EXTENSIONS
ED- TRUNK CONTROL, RING CONTROL
Description
Use ED- Ring Control to set ringing options for each trunk at each 
The options are:
Related
Programming
l
l
R
D
L
N
 Ringing  Phone starts ringing as soon as line key begins to
flash
Delayed Ringing 
 Phone starts ringing after the delayed ring interval (the
line key flashes immediately). Refer to QT- System Timers, Delayed Ring
Interval when setting the delayed ring interval.
Lamp Only (no ringing) 
 Phone never rings (line key only flashes)...

Page 378

E- EXTENSIONS
ED- TRUNK 
CONTROL, RING CONTROL
Related
Programming
(Cont’d)
l
l
l
l
l
l
E- Extensions, ED- Trunk Control. Access Control  An extension must
have access to a DID trunk in order to answer a DID call on that trunk.
E- Extensions/Trunks,  Class of Service  Assign Class of Service to
DID trunks and extensions.
E- Trunks, Et- Circuit Tvpe  Assign DID trunks with circuit type 07.
E- Trunks,    Number  Enter the  circuit number for the
DID trunk. Refer to the 
 Installation and Programming Manual...

Page 379

E- EXTENSIONS
ED- TRUNK 
 RING CONTROL
Feature Reference
Instructions
Step  
Step  
Step 2 
Step 3 
Step 
Central Office Calls. Answering
Direct Inward Dialing
Night Answer. Assigned Night 
Private Line
Tenant Service
To enter data on the PRF:
For each extension. enter each trunk’s Ring Control option on Table 6.
To enter data at the programming terminal:
Type 
ED. You see:  300
Press RETURN to program extension 300.
OR
Enter another extension number and press RETURN. In either case, you see:
RING...

Page 380

E- EXTENSIONS
ED- TRUNK CONTROL, ACCESS CONTROL
Description
Note:
Related
Programming
l
l
P
P
Use ED- Access Control to set the access options for each trunk at each
extension. If allowed in other programming, an extension can place and
answer calls on trunks to which it has access.
Keep the following features in mind when programming Access Control:
 Call Parking
An extension can only pick up parked calls on trunks to which it has access.
 Central Office Calls. Answering and PlacingAssign access for the...