Page 232
19-1 Section 19 eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS 19.1 GENERAL This section provides a description of unite programming requirements for emaGEN, utilizing the unite eManager. It is assumed that the technician or System Administrator per- forming the following system configuration procedures is thor- oughly familiar with the use of the unite eManager. For further information on unite system configuration pro- gramming, see the unite family of Systems Administration manual. 19.2...
Page 233
76-110-0887/0, Issue 1 19-2 balance system load and improve performance by programming one of the OCD card to handle the emaGEN ports supporting System Dial By Name. You may consider these reasons impor- tant enough to have a second OCD card even with an eMAGEN system of 12 or fewer ports; An OCD card can be located in any card position except for the slot reserved for the MPD card. The selected OCD card position may be either: An undefined card position; A card position previously defined...
Page 234
Section 19: eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS 19-3 The program displays the Units/Resources Information window, containing the question: Units/Resources Info (U/R): 2. Press the [Resources selection] button to obtain a display of system resources. The screen displays information on the already assigned relays, sensors, DTMFs, and voice channels, located on installed OCD and MPD cards (STS model only in unite 400 system) in your unite system. NOTE You cannot add any information to...
Page 235
76-110-0887/0, Issue 1 19-4 Entering an unassigned card position or a position assigned to a card other than an OCD or COL/CHL/COG card brings an error message. For emaGEN programming purposes, data entry only deals with OCD cards. The program automatically displays the default baud rate appropri- ate to the application. 4. Leave the parity field blank when entering IVM1 or IVM2 in one of the APP fields. 5. Enter IVM 1 in the APP1 field. If you make the entry without a space, the system will...
Page 236
Section 19: eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS 19-5 provides blank fields for entering voice channel and DN numbers for each emaGEN voice mail port To complete the screen: 1. Move the cursor to the first position in the Voice channel column, opposite emaGEN Card #1, Port number 1. 2. Type in the number of the first of the assigned voice channels viewed and noted in step 3 of Section 19.2.1 above. You cannot enter a voice channel number unless you have defined the MIM in the section...
Page 237
76-110-0887/0, Issue 1 19-6 NOTE You cannot add any information to the DN LIST Screen. 7. Continue in similar fashion, assigning voice channels and DNs to all the emaGEN ports in your system. 8. Press the [Save] icon to save your data entry. 19.2.3emaGEN configurations Following are summaries of different possibilities for the physical configuration of emaGEN. To install emaGEN with up to 12 or 16 ports You require: One emaGEN card -- of either the Vantage Volare, Quartet or RDSP 432 type -- in...
Page 238
Section 19: eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS 19-7 To solve a problem of very heavy signaling traffic: If you have installed emaGEN and your system exhibits a problem of very heavy signaling traffic, you can solve this problem by using two RS232 cables. This requires: One emaGEN-PC Two emaGEN cards installed in the PC Two RS232 cables Two OCD cards with sufficient MIM modules defined on them. To program this configuration: 1. Use the first RS232 cable to connect the first OCD...
Page 239
76-110-0887/0, Issue 1 19-8 unite system: Press the [DN List] icon. The DN LIST Screen appears. Remember that the screen is for viewing only; you cannot add any information. 4. Select any available legal extension. 5. Enter the necessary parameters for the hunt group dedicated to emaGEN. These parameters are: DN of the emaGEN hunt group; The name of the emaGEN hunt group, consisting of up to five alphanumeric characters, such as, IVMHN, for example; Hunt type, the type of search the emaGEN...
Page 240
Section 19: eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS 19-9 925 entries in a unite 1000 system. In the first field, enter the first DN to be assigned to the emaGEN hunt group: 2. Type the DN number. 3. Press ENTER. The DN numbers which will belong to the group should be identi- cal, in numbers and in sequence, with the DN numbers of the ports/voice channels that were assigned in Section 19.2.2, above. 4. Following the same procedure, type in the DN numbers of all the members of the emaGEN...