Page 231

76-110-0887/0, Issue 1
18-8
THIS PAGE INTENTIONALLY BLANK 

Page 232

19-1
Section 19 
eManager PROGRAMMING FOR 
emaGEN IN unite SYSTEMS
19.1 GENERAL
This section provides a description of unite programming 
requirements for 
emaGEN, utilizing the unite eManager. 
It is assumed that the technician or System Administrator per-
forming the following system configuration procedures is thor-
oughly familiar with the use of the 
unite eManager.
For further information on 
unite system configuration pro-
gramming, see the 
unite family of Systems Administration 
manual.
19.2...

Page 233

76-110-0887/0, Issue 1
19-2
balance system load and improve performance by programming 
one of the OCD card to handle the 
emaGEN ports supporting 
System Dial By Name. You may consider these reasons impor-
tant enough to have a second OCD card even with an 
eMAGEN 
system of 12 or fewer ports;
 An OCD card can be located in any card position except for the 
slot reserved for the MPD card.
The selected OCD card position may be either:
 An undefined card position;
 A card position previously defined...

Page 234

Section 19:  eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS
19-3
The program displays the Units/Resources Information window, 
containing the question:
 
Units/Resources Info (U/R):
2. Press the [Resources selection] button to obtain a display of 
system resources.
The screen displays information on the already assigned relays, 
sensors, DTMFs, and voice channels, located on installed OCD 
and MPD cards (STS model only in 
unite 400 system) in your 
unite system.
NOTE
You cannot add any information to...

Page 235

76-110-0887/0, Issue 1
19-4
Entering an unassigned card position or a position assigned to a 
card other than an OCD or COL/CHL/COG card brings an error 
message. For 
emaGEN programming purposes, data entry only 
deals with OCD cards.
The program automatically displays the default baud rate appropri-
ate to the application.
4. Leave the parity field blank when entering IVM1 or IVM2 in one 
of the APP fields.
5. Enter IVM 1 in the APP1 field.
If you make the entry without a space, the system will...

Page 236

Section 19:  eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS
19-5
provides blank fields for entering voice channel and DN numbers 
for each 
emaGEN voice mail port 
To complete the screen:
1. Move the cursor to the first position in the Voice channel column, 
opposite 
emaGEN Card #1, Port number 1.
2. Type in the number of the first of the assigned voice channels 
viewed and noted in step 3 of Section 19.2.1  above.
You cannot enter a voice channel number unless you have defined 
the MIM in the section...

Page 237

76-110-0887/0, Issue 1
19-6
NOTE
You cannot add any information to the DN
LIST Screen. 
7. Continue in similar fashion, assigning voice channels and DNs to 
all the 
emaGEN ports in your system.
8. Press the [Save] icon to save your data entry.
19.2.3emaGEN configurations
Following are summaries of different possibilities for the physical 
configuration of 
emaGEN.
To install 
emaGEN with up to 12 or 16 ports
You require:
One 
emaGEN card -- of either the Vantage Volare, Quartet or 
RDSP 432 type -- in...

Page 238

Section 19:  eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS
19-7
To solve a problem of very heavy signaling traffic:
If you have installed 
emaGEN and your system exhibits a problem 
of very heavy signaling traffic, you can solve this problem by using 
two RS232 cables. This requires:
One 
emaGEN-PC
Two 
emaGEN cards installed in the PC
 Two RS232 cables
 Two OCD cards with sufficient MIM modules defined on them.
To program this configuration:
1. Use the first RS232 cable to connect the first OCD...

Page 239

76-110-0887/0, Issue 1
19-8
unite system:
Press the [DN List] icon.
The DN LIST Screen appears. Remember that the screen is for 
viewing only; you cannot add any information.
4. Select any available legal extension.
5. Enter the necessary parameters for the hunt group dedicated to 
emaGEN.
These parameters are:
 DN of the 
emaGEN hunt group;
 The name of the 
emaGEN hunt group, consisting of up to five 
alphanumeric characters, such as, IVMHN, for example;
 Hunt type, the type of search the 
emaGEN...

Page 240

Section 19:  eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS
19-9
 925 entries in a unite 1000 system.
In the first field, enter the first DN to be assigned to the 
emaGEN 
hunt group:
2. Type the DN number.
3. Press ENTER. 
The DN numbers which will belong to the group should be identi-
cal, in numbers and in sequence, with the DN numbers of the 
ports/voice channels that were assigned in Section 19.2.2, 
above.
4. Following the same procedure, type in the DN numbers of all the 
members of the 
emaGEN...