Home > Telrad Digital > Communications System > Telrad Digital Emagen Unified Messaging System Manual

Telrad Digital Emagen Unified Messaging System Manual

Here you can view all the pages of manual Telrad Digital Emagen Unified Messaging System Manual. The Telrad Digital manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 251

76-110-0887/0, Issue 1
19-20
 Second overflow priority, the priority given to a call overflowing to 
the second overflow group when it enters that group queue; 
 Third overflow time, the amount of time that an unanswered call 
can remain in the queues of the main, first, and second ACD 
groups before it begins to ring in the third ACD overflow queue 
as well;
 Third overflow group, the number of the third ACD group, in addi-
tion to the first three groups, to receive unanswered calls from 
this ACD...

Page 252

Section 19:  eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS
19-21
3. Press the [Save] icon to save your data entry.
19.10.4 Announcement Program Screen 
You use the Announcement Program Screen to build the desired 
Announcement Program or order of announcements played by each 
of the Announcer Plans, whose parameters you defined in the sec-
tion above.
You are able to define a maximum of 50 elements for each 
Announcement Program. The screen informs you of the number of 
available entries. This...

Page 253

76-110-0887/0, Issue 1
19-22
1. From the System Parameters heading, select the System Timers 
Screen.
The program displays the System Timers S-T Screen.
2. Set the Centrex or PABX Flash timer to 0.30 seconds, as appro-
priate.
3. Press the [Save] icon to save your data entry.
19.12IMPLEMENTING A NETWORKED emaGEN SYSTEM 
Networked unite systems can share a common emaGEN system. 
This requires a few differences in the 
unite system configuration 
programming at the networked exchanges. 
19.12.1   IVM hunt...

Page 254

Section 19:  eManager PROGRAMMING FOR emaGEN IN unite SYSTEMS
19-23
NOTE
This is represented by a number such as
S1:302, where 1 is the number of the sys-
tem speed dial table and 302 is the number
of the bin. Note that you cannot access
emaGEN using a different speed dial bin
programmed with the same contents. Only
the speed dial bin specified in the IVM Hunt
Group Screen accesses IVM.
In the System Speed Dial Numbers S-S-N Screen in the Pro-
grammed Number parameter, enter the digits of the prefix of...

Page 255

76-110-0887/0, Issue 1
19-24
THIS PAGE INTENTIONALLY BLANK 

Page 256

Catalog No. 76-110-0887/0
Release 1.0
Issue 1
Telrad Tenecss Inc.
Woodbury, New York
Printed in Israel 
Start reading Telrad Digital Emagen Unified Messaging System Manual

Related Manuals for Telrad Digital Emagen Unified Messaging System Manual

All Telrad Digital manuals