Panasonic Network Camera Wv Sfv481 Operating Instructions
Here you can view all the pages of manual Panasonic Network Camera Wv Sfv481 Operating Instructions. The Panasonic manuals for Security Camera are available online for free. You can easily download all the documents as PDF.
Page 161
IPv6 network[Manual] Select “On” or “Off” to determine whether or not to manually configure the IP address for IPv6 network (IPv6 address). • On: Enter an IPv6 address manually. • Off: Manual entry of an IPv6 address will become unavailable. • Default: Off [IP address(IPv6)] When “On” is selected for “Manual”, manual entry of the IPv6 address is required. Do not enter an address already in use. Note •When connecting to the manually configured IPv6 address beyond the router, use an IPv6 compatible...
Page 162
[Max RTP packet size] Select “Unlimited(1500byte)” or “Limited(1280byte)” to determine whether or not to restrict the RTP packet size when viewing images from the camera using the RTP protocol. It is recommended to use with the default “Unlimited(1500byte)”. When the RTP packet size is restricted in the network line in use, select “Limited(1280byte)”. Refer to the network administrator for further information about the maximum packet size in the network line. • Default: Unlimited(1500byte) [HTTP max...
Page 163
•To access the camera via the Internet by connecting the camera to a router, it is necessary to assign a respective HTTP port number for each camera and address translation by using the port forwarding function of the router. For further information, refer to the operating instructions of the router in use. [FTP access to camera] Select “Allow” or “Forbid” to determine whether to allow or forbid the FTP access to camera. • Default: Forbid 15.2 Configure advanced network settings [Advanced] Click the...
Page 164
15.2.1 Configure the settings related to sending E-mails [E-mail notification] Select “On” or “Off” to determine whether or not to provide notification by E-mail according to the settings for the “Alarm” and “Diag.” checkboxes of “Destination of notification” below. – When an alarm is detected (“Alarm”) – When a notification of the remaining capacity of the SD memory card has been provided (“Diag.”) – When the SD memory card has become full (“Diag.”) – When the SD memory card cannot be recognized...
Page 165
[Image capture size] Select the image capture size of images attached to an alarm E-mail from the following. JPEG(1)/JPEG(2) • Default: JPEG(1) [SMTP server address] Enter the IP address or the host name of the SMTP server used to send E-mails. • Available number of characters: 1 - 128 characters • Available characters: Alphanumeric characters, the colon (:), the period (.), the underscore (_), and the hyphen (-). [SMTP port] Enter the port number to which E-mails are sent. • Available port number:...
Page 166
•Available characters: Alphanumeric characters, the at sign (@), the period (.), the underscore (_), and the hyphen (-). [SSL] Select “On” if you want to use SSL encryption when sending E -mail notifications for alarm occurrences or the “Diag.” function. When you select “On”, the authentication method will be set to “SMTP”. Set the user name and the password used for authentication. • Default: Off Note •Some SMTP servers may not support SSL. • SSL supports SMTP over SSL, but STARTTLS is not...
Page 167
•When “On(NTSC)” or “On(PAL)” is selected for “Monitor out”, FTP transmission is unavailable. FTP [Alarm image FTP transmission] Select “On” or “Off” to determine whether or not to transmit the alarm image to the FTP server. • Default: Off [Directory name] Enter the directory name where the alarm images are to be saved. For example, enter “/ALARM” to designate the directory “ALARM” under the root directory of the FTP server. • Available number of characters: 1 - 256 characters • Unavailable characters:...
Page 168
•Unavailable characters: " & * / : ; < > ? \ | [FTP transmission retry] Select “On” or “Off” to determine whether or not to resend failed FTP transmissions. On: If transmission fails, transmissions are resent until they are successfully sent. Off: If transmission fails, the image that failed to be sent is discarded and the next image is sent. Default: Off [Pre alarm] • Transmission interval Select the update interval of images before an alarm occurs from the following. 0.1fps/ 0.2fps/ 0.33fps/...
Page 169
•Default: 1fps • Number of images Select the number of images to be transmitted from the following. 1pic/ 2pics/ 3pics/ 4pics/ 5pics/ 6pics/ 7pics/ 8pics/ 9pics/ 10pics/ 20pics/ 30pics/ 50pics/ 100pics/ 200pics/ 300pics/ 500pics/ 1000pics/ 1500pics/ 2000pics/ 3000pics • Default: 100pics • Recording duration Approximate time to be taken to save the set “Number of images” with the set “Transmission interval” will be displayed. [Image capture size] Select the image capture size of images transmitted...
Page 170
1s/ 2s/ 3s/ 4s/ 5s/ 6s/ 10s/ 15s/ 20s/ 30s/ 1min/ 2min/ 3min/ 4min/ 5min/ 6min/ 10min/ 15min/ 20min/ 30min/ 1h/ 1.5h/ 2h/ 3h/ 4h/ 6h/ 12h/ 24h • Default: 1s [Image capture size] Select the image capture size of images to be transmitted from the following. JPEG(1)/JPEG(2) • Default: JPEG(1) [FTP server address] Enter the IP address or the host name of the FTP server. • Available number of characters: 1 - 128 characters • Available characters: Alphanumeric characters, the colon (:), the period (.), the...