Panasonic DBS 576HD Technical Manual
Have a look at the manual Panasonic DBS 576HD Technical Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Section 700 - Operation Chapter 7. SLT Features 576-50-700 DBS 576HD (USA) issued September 2001 5-79 • Storing a new number erases any previously stored data. • If the called party’s number and name are stored in the PSD code, that information appears on the display when you use the speed dial code. • Speed dial numbers can contain up to 24 characters. The following table reflects which keys to use. * Indicates that the digits that follow are either a feature access code or an extension number. (Not needed if your System is set for Intercom Level.) See Note below. ** Indicates that the digits that follow are for an outside number and the System should seize the next available trunk when dialing. (Not needed if your System is set for CO Level.) See Note below. *** Indicates that the enclosed digits should not be displayed during dialing. Must precede and follow the digits that you do not want displayed. Example: AUTO *2 555-4143 AUTO *2. Note:The System has two levels - CO Level and Intercom Level. If set at CO Level (default), you must enter the code for Intercom Level when programming a feature access code or extension number for speed dialing. If the System is set at Intercom Level, you must enter the MCO Code when programming an outside number for speed dialing. System Speed Dial You can store frequently called numbers using the SSD feature. Either 80 or 800 SSD numbers can be programmed, depending on how the System is configured. In an 80 SSD-number system, the SSD numbers are stored in bins 00-79. In 800 SSD-number systems, the SSD numbers are stored in bins 000-799. Operation To assign SSD numbers:To indicate. . . Enter/Press Shown on Display? Digit or character0, 1 - 9, *, #yes (unless preceded by AUTO * 2 - see *** below) Intercom Level *AUTO * #no MCO Code **AUTO * 0no PauseREDIALno DP - DTMF CodeAUTO * *no SSD CodeAUTO NN(N)no Hyphen (-)PROGyes Display Number (Start / Stop) ***AUTO * 2 DTMF Conversion After the Other Party AnswersAUTO * 3 Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone
5-80 DBS 576HD (USA) issued September 2001 576-50-700 Chapter 7. SLT Features Section 700 - Operation To dial an SSD number by entering the speed dial bin number: To check an SSD number:Action Result 2. (A) Press the PROG key. (B) Press the AUTO key. OR... (A) Enter the Speed Dial Set/Clear code (default = 710). 3. Enter the SSD bin number (00-79 or 000-799).Enter Spd Dial displays 4. Dial the phone number. 5. Press the HOLD key.Stored Spd Dial displays 6. Replace the handset or press the ON/OFF key. Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone 2. If necessary, access an outside line. Outside dial tone 3. Press the AUTO key. OR... Enter the Speed Dial Originate code (default = 80).A displays 4. Enter the SSD bin number (00-79 or 000-799). 5. Complete the call and replace the handset or press the ON/ OFF key. Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone 2. Press the CONF key.C displays 3. Press the AUTO key. 4. Enter the SSD bin number (00-79 or 000-799). Programmed data displays 5. If you want to check the next SSD number, press the HOLD key. 6. Replace the handset or press the ON/OFF key.
Section 700 - Operation Chapter 7. SLT Features 576-50-700 DBS 576HD (USA) issued September 2001 5-81 To delete an SSD number: Hardware Requirements •N/A Related Programming • FF1-0-15, 16, & 17: SSD Blocks • FF1-0-02: SSD Digits • FF1-0-03: Extension COS (SSD Assignment) • FF8-1-02: SSD Number • FF8-1-02: SSD Name Considerations • If numbers do not appear on the display when you use SSD codes (00-79 or 000-799), your extension is not programmed to display that data. • The System can be programmed to allow SSD numbers to override toll restrictions. Speed Dial Linking You can automatically link together up to 6 SSD numbers in 1 PSD bin to handle telephone numbers longer than 24 characters. You can then dial the entire number by pressing the programmed PSD key or by entering the speed dial bin number. Alternatively, any combination of PSDs and SSDs can be manually linked together by pressing the keys in the desired sequence. This can be useful for prepending account codes or long distance carrier access codes, etc. Note:Before linking multiple SSD numbers to a PSD bin, the SSD bins must already have been programmed with the appropriate speed dial information.Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone 2. (A) Press the PROG key. (B) Press the AUTO key. OR... (A) Enter the Speed Dial Set/Clear code (default = 710). 3. Enter the SSD bin number (00-79 or 000-799). 4. Press the HOLD key.Cleared Spd Dial displays 5. Replace the handset or press the ON/OFF key.
5-82 DBS 576HD (USA) issued September 2001 576-50-700 Chapter 7. SLT Features Section 700 - Operation Operation To link multiple SSD numbers to a PSD bin: To use a PSD Key that links multiple SSDs: To manually link speed dial keys together: Hardware Requirements •N/AAction Result 1. Determine the SSD bin numbers to be linked 2. Lift the handset or press the ON/OFF key. 3. (A) Press the PROG key. (B) Press the AUTO key. OR... (A) Enter the Speed Dial Set/Clear code (default = 710). 4. Enter the PSD bin number (80-90).Enter Spd Dial displays 5. Press the AUTO key. 6. Enter the SSD bin number (00-79 or 000-799) that contains the first part of the number to be dialed. 7. Repeat steps 5-6 up to 5 more times for all additional SSDs to be dialed. 8. Press the HOLD key when finished.Stored PSDXXX displays Action Result 1. If necessary, select the trunk group (9, 81-84). (Normally the trunk is selected by the speed dial numbers.) 2. Press the PSD key. Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone 2. If necessary, access an outside line. 3. If you are using a PSD number, press the one-touch key for the first part of the number. If you are using an SSD number, press the AUTO key, then enter the SSD bin number. 4. Use the one-touch keys or press the AUTO key and enter the SSD codes to dial the parts of the phone number until it is completed.
Section 700 - Operation Chapter 7. SLT Features 576-50-700 DBS 576HD (USA) issued September 2001 5-83 Related Programming •N/A Considerations •N/A Speed Dial Name Assignments You can assign names to PSD numbers from a key telephone without entering the programming mode. If allowed in the Extension Class of Service (COS), you can also assign names to SSD numbers. (PSD names can contain a maximum of 7 characters. SSD names can contain a maximum of 16 characters.) Operation PSD Names: To set PSD names using a large-display or small-display phone: Action Result 1. Lift the handset or press the ON/OFF key. 2. Press the PROG key. 3. Press the * key. 4. Enter 0 for the PSD Name Assignment mode.A B C D E F P80 displays (where P80 = PSD bin 80) 5. Press the VOLUME up or down arrow key to display the desired PSD bin number.A B C D E F PXX displays (where PXX = desired PSD bin number) 6. Enter the extension name: • If using a large-display phone, press the soft key next to the desired row of letters. (See Example 1 on page 5-84.) • If using a small-display phone press the appropriate one-touch key. (See Example 2 on page 5-86.) Note: Press the FLASH key to clear any existing data 7. Use the bottom row of FF keys to select a single letter. • See “Example 1. Large-display phone” on page 5-84. • See “Example 2. Small-display phone” on page 5-86. Notes: • Press the * key to erase a single entry. • Press the # key to enter a space. 8. Repeat steps 6-7 as many times as necessary to enter the desired PSD name. Note: Press the FLASH key to clear the entire entry. 9. Press the HOLD key when finished. Next PSD bin number displays 10. To enter another speed dial name repeat steps 5-9.
5-84 DBS 576HD (USA) issued September 2001 576-50-700 Chapter 7. SLT Features Section 700 - Operation SSD Names: To set SSD names using a large-display or small-display phone: Example 1. Large-display phone To e n t e r D: a. Press the first soft key on the top left. Action Result 1. Lift the handset or press the ON/OFF key. 2. Press the PROG key. 3. Press the * key. 4. Enter 1 for the SSD Name Assignment mode.SSD NO.=> SSD NAME displays 5. Enter the speed dial bin number (00-79 or 000-799). 6. Press the HOLD key.-SSDXXX A B C D E F XXX displays (where XXX = specified SSD bin number) 7. Press the FLASH key to clear the current data.A B C D E F XXX displays (where XXX = specified SSD bin number) 8. Enter the speed dial name: • If using a large-display phone, press the soft key next to the desired row of letters. (See Example 1 on page 5-84.) • If using a small-display phone press the appropriate one-touch key. (See Example 2 on page 5-86.) 9. Use the bottom row of FF keys to select a single letter. • See “Example 1. Large-display phone” on page 5-84. • See “Example 2. Small-display phone” on page 5-86. Notes: • Press the * key to erase a single entry. • Press the # key to enter a space. 10. Repeat steps 8-9 as many times as necessary to enter the desired SSD name. Note: Press the FLASH key to clear the entire entry. 11. Press the HOLD key when finished. Next SSD bin number displays 12. To enter another speed dial name, press the CONF key and repeat steps 5-11.SSD NO.=> SSD NAME displays
Section 700 - Operation Chapter 7. SLT Features 576-50-700 DBS 576HD (USA) issued September 2001 5-85 b. Press the fourth FF key from the left on the bottom row. To e n t e r o: a. Press the third soft key from the top right. b. Press the third FF key from the left on the bottom row.
5-86 DBS 576HD (USA) issued September 2001 576-50-700 Chapter 7. SLT Features Section 700 - Operation Example 2. Small-display phone Refer to the following diagram to determine which one-touch key to press. (See step 7-8 above.) To e n t e r D: a. Press the first one-touch key from the left on the bottom row. b. Press the fourth FF key from the left on the bottom row. G H I J K L M N O P Q R S T U V W X A B C D E F Y Z . , ’ - a b c d e fg h i j k lm n o p q rs t u v w xy z : & / sp END MODE
Section 700 - Operation Chapter 7. SLT Features 576-50-700 DBS 576HD (USA) issued September 2001 5-87 To e n t e r o: a. Press the third one-touch key from the left on the top row. b. Press the third FF key from the left on the bottom row. Hardware Requirements •N/A Related Programming • FF1-0-03: Extension COS (User Log-in) • FF3: Extension COS • FF8-1: SSD & PSD Considerations • The ability to assign SSD names is allowed/restricted to anyone with a COS that allows access to User Maintenance features. (See Chapter 4 “User Maintenance” of this document.) Station Lockout Description Use the Station Lockout feature to limit use of your phone by others when you are away from your telephone. When the Station Lockout feature is in use, the TRS Class of your telephone is changed. Anyone using your telephone is limited to the calling abilities defined by this Lockout TRS Class. In addition, with the appropriate COS, you can set or cancel Station Lockout for other telephones. END MODE PROG CONF
5-88 DBS 576HD (USA) issued September 2001 576-50-700 Chapter 7. SLT Features Section 700 - Operation Operation To activate Station Lockout feature: To cancel Station Lockout feature: To activate Station Lockout feature for another extension: To cancel Station Lockout feature for another extension:Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone 2. Enter the Station Lockout feature code (default = 746).St. Lock Set displays 3. Replace the handset or press the ON/OFF key.Lock displays Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone 2. Enter the Station Lockout feature code (default = 746) .Enter ID Code displays 3. Enter the Walking TRS/Station Lockout security code. Cleared St. Lock displays 4. Replace the handset or press the ON/OFF key. The telephone display returns to the nor- mal display. Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone 2. Enter the Station Lockout for another extension feature code (default = 747).Enter Lock EXT # displays 3. Dial the extension number to activate station lockout.St. Lock Set displays 4. Replace the handset or press the ON/OFF key. Action Result 1. Lift the handset or press the ON/OFF key. Intercom dial tone 2. Enter the Station Lockout feature code (default = 748).Enter Lock EXT #displays 3. Enter the extension number to activate station lockout.Enter ID Code displays 4. Enter the Walking TRS/Station Lockout security code. Cleared St. Lock displays 5. Replace the handset or press the ON/OFF key. The telephone display returns to the nor- mal display.