Page 241

System prgming / 241
P0603539  02Compact ICS 6.1 Installer Guide
Alarm 79 will be logged followed by the DN of the set from where 
the session was running
Network Name DisplayInstaller password required
Norstar will display the name of the calling party when it is provided by 
Public ISDN BRI interfaces. The displayed name may includes 
information such as the Receiving Calling Name and Receiving Redirected 
Name.
Receiving Calling Party Name
Network name display allows the name of an incoming BRI call...

Page 242

242 / System prgming
Compact ICS 6.1 Installer GuideP0603539  02
Intrl modemInstaller password required
The internal modem used for remote programming or monitoring can 
operate at two different speeds. The fast speed setting uses the V.32 bis 
modem standard, which supports baud rates of 4.8 kbps to 14.4 kbps. In 
some cases, network limitations may prevent the modem from connecting 
at the fast speed. If you consistently have problems making calls to or from 
particular destinations, select the slow...

Page 243

System prgming / 243
P0603539  02Compact ICS 6.1 Installer Guide
Alarm reportingInstaller password required
The Alarm Reporting subheading will not appear unless your Feature 
Cartridge comes with remote administration enabled, or you have enabled 
the feature using software keys. See the I-RAD chapter and Software Keys 
on page 255 for more information.
The Norstar system can use the internal remote access device 
(I-RAD) to automatically send an alarm code to a remote location when it 
detects a...

Page 244

244 / System prgming
Compact ICS 6.1 Installer GuideP0603539  02
The baud rate you select for the device which will receive the alarm report 
should support the baud rate of the Compact ICS internal modem. See page 
242 for more information.
Auto-report
Press CHANGE to select the setting: OFF or ON.
Phone #1
Press CHANGE and enter the telephone number the system will dial to 
transmit an alarm code. Press 
OK when you have finished entering the 
number. It can be up to 24 digits long.
Press 
CLR to...

Page 245

System prgming / 245
P0603539  02Compact ICS 6.1 Installer Guide
Retry time
Press CHANGE and enter the length of time in minutes the I-RAD will wait 
before trying the pre-programmed telephone number again. Enter a number 
between 1 and 50.
Press 
CLR to reset Retry time to the default (15 minutes).
Num. retries
Press CHANGE to select the number of times the system will retry the 
transmission of the alarm code: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9.
Press 
CLR to reset the number of retries to the default (5...

Page 246

246 / System prgming
Compact ICS 6.1 Installer GuideP0603539  02
Simple or Detailed text. When the default None is selected, no release 
reasons appears on the set. 
Release Reasons can be programmed under System prgrming. With the 
display showing 
System prgming.
1. Press 
‘ until the display shows Release reasons.
2. Press 
≠. The display shows Text: None.
3. Select the text to be displayed as Simple or Detailed.
If you selected Simple text, press 
‘ for Cause code. The Cause 
code 
is for...

Page 247

System prgming / 247
P0603539  02Compact ICS 6.1 Installer Guide
Call restrns
You can set up call restrictions based on room occupancy states. This 
setting affects the Room occupancy feature.
1. At the Hospitality heading, press 
≠ twice. Call restrns 
displays.
2. Press 
≠. Vacant:00 displays.
3. Press 
CHANGE and enter the filter that defines the restrictions for your 
hospitality system. 
4. Repeat steps 2 and 3 for the other room occupancy states.
The table below shows an example of a call...

Page 248

248 / System prgming
Compact ICS 6.1 Installer GuideP0603539  02
Alarms
Use this feature to create the alarm settings that will govern the alarm 
features for both the administrative and room sets.
1. At the Hospitality heading, press 
≠ until Alarm displays.
2. Press 
≠. Attn attempts:3 displays.
3. Press 
CHANGE until you find the number you want (1-5). 
4. Press 
‘. Retry intrvl:4 displays.
5. Press 
CHANGE until you find the number you want (2, 4, 6, or 8). 
6. Press 
‘. Attn duration: 15 displays....

Page 249

ETSI: Network features (profile 2) / 249
P0603539  02Compact ICS 6.1 Installer Guide
ETSI: Network features (profile 2)
If you are using Profile 2 for your system, and your service provider 
supports the features on your ETSI ISDN lines, you can configure  your 
system to allow network diversion and/or Malicious Caller ID (MCID) 
recording.
To program these features:
1. With the display showing 
System prgming press ‘ until the 
display shows 
NetworkServices.
2. Press 
≠.  ETSI displays.
3. Press 
≠...

Page 250

250 / ETSI: Network features  (profile 2)
Compact ICS 6.1 Installer GuideP0603539  02
Feature description
NCD is available only over ETSI ISDN lines. It can be invoked when calls 
are presented to Norstar/BST extensions over ISDN lines. The user must 
program the selected extension.
NCD is integrated with the following existing Norstar Call Forward 
features:
Call Forward All Calls (CFAC)—implemented on Norstar Call 
Forward All Calls (CFAC) 
²Ý, and Selective Line Redirection 
(SLR) 
²¡Ý, also referred...