Page 281
Problems with the I-ATA / 281 P0603539 02Compact ICS 6.1 Installer Guide 5. Run a maintenance session to ensure the I-ATA is not disabled. Refer to Port/DN status on page 308. Calls cannot be answered (or dial tone is not present when making calls) 1. Check that the I-ATA connections have been made correctly. 2. Replace the analog device with a single-line analog telephone and check for dial tone. 3. Ensure that the analog device is not faulty by connecting it directly to an external line and...
Page 282
282 / Problems with the I-ATA Compact ICS 6.1 Installer GuideP0603539 02 5. Check the internal wiring at the modular jack and the distribution cross-connect. The I-ATA port should have about 31 Vdc across the Tip and Ring when the telephone is disconnected. The voltage should drop when the analog telephone is connected and a call is attempted. 6. Check the requirements of the analog device to see if it is compatible with the I-ATA specifications. Refer to Specifications on page 343.
Page 283
Problems with optional equipment / 283 P0603539 02Compact ICS 6.1 Installer Guide Problems with optional equipment Auxiliary ringer 1. If the auxiliary ringer is used for Schedules (Night, Evening, or Lunch schedule), ensure that Schedules is activated from the control telephone. 2. Check the wiring between the auxiliary ringer generator and the ringing device. Refer to the auxiliary ringer wiring chart. 3. Check the wiring between the auxiliary ringer generator and the distribution block....
Page 284
284 / Problems with optional equipment Compact ICS 6.1 Installer GuideP0603539 02 External paging 1. Use the Button Inquiry feature (²¥â) to verify the feature of a programmable memory button. 2. Check the wiring between the 50-pin connector and the paging amplifier or between the connections shown in the external paging wiring chart. External paging wiring 3. Test external paging ²ßÛ to ensure that it is working. The nominal output signal from the Norstar ICS is 100 mV rms across 600 Ω. Music on...
Page 285
Problems with optional equipment / 285 P0603539 02Compact ICS 6.1 Installer Guide 4. Check the wiring between the music source and the 50-pin connector. See the wiring charts in the Installation section. 5. Ensure that the music source is turned on, is operational, and the volume control is set properly. 6. Any music source with a low-output impedance (for example, less than 3,300 ohms) can be connected. The output level must be less than one volt. KIM not working The key interface module (KIM) that...
Page 286
286 / Problems with optional equipment Compact ICS 6.1 Installer GuideP0603539 02 • KIM single-module coldstart If you just want to coldstart an individual module: While the reset icons are still flashing, simultaneously press the two top and two bottom buttons on the lower button set. The KIM displays a random pattern of icons as the KIM resets. KIM multi-module coldstart If you want to coldstart all the KIMs attached to your telephone: While the rest icons are still flashing, on the first...
Page 287
Problems with Trunk Cartridges / 287 P0603539 02Compact ICS 6.1 Installer Guide Problems with Trunk Cartridges Check first for user configuration problems, then wiring and programming errors before replacing Norstar equipment. Trunk Cartridge trouble 1. Check that the cartridge is properly inserted in the ICS. 2. Run a Maintenance session to ensure that the cartridge is not disabled. If the problem persists: 1. If AC power is present and the LED indicator on the ICS is off, see the section on ICS down...
Page 288
288 / Problems with BRI service Compact ICS 6.1 Installer GuideP0603539 02 Problems with BRI service Each LED on front of a BRI-ST or BRI-U Card corresponds with a loop, or indicates an overall state of the BRI connections. The BRI card is connected to the ISDN network (U-loop) but the LED for one of more loops is not lit Possible problem The physical connection or configuration for the network connection is not correct (no Layer 1). Solution 1. Verify the wiring from the network to the...
Page 289
Problems with BRI service / 289 P0603539 02Compact ICS 6.1 Installer Guide 6. Verify that the loop is properly configured, including the proper loop type, SPIDs, and Network DNs. 7. Disable and re-enable the BRI Card. 8. Disable and enable the module for the Card. Out of service is displayed when a BRI line is selected (LED for loop is lit) Possible problem The loop is configured incorrectly. Layer 1 is present but Layers 2 and 3 are not working. Solution 1. Verify that the SPIDs and Network DNs are...
Page 290
290 / Problems with BRI service Compact ICS 6.1 Installer GuideP0603539 02 2. Replace the card with another card of the same type. Caller hears one ring and then a fast busy signal when placing a call on a BRI line Possible problem CACH or EKTS, which are not supported by Compact ICS, is included in the ISDN services package. Solution 1. Contact your service provider and ensure that CACH or EKTS are not part of the ISDN services package. These services must be turned off at the switch. 2. Verify...