Page 141

Programming / 141
P0603539  02Compact ICS 6.1 Installer Guide
Entering programming using other passwords
A set of the most often used headings and subheadings is available by using 
a System Coordinator password (see page 120). This level of access is 
designed for the person who takes care of the day-to-day changes to the 
Norstar system, but who is not interested in more advanced programming. 
The default password is ADMIN (23646).
There is also a Basic password that can be used to perform a few...

Page 142

142 / Terminals&Sets
Compact ICS 6.1 Installer GuideP0603539  02
Terminals&Sets
Terminals&Sets allows you to assign settings to each telephone.
Press 
≠ and enter the extension number of the telephone you 
would like to program.
Press 
COPY to duplicate the programming for the telephone and apply it to 
another telephone, a range of telephones or all the telephones on the 
system. For more information about copying set programming, see 
Copying telephone programming on page 128.
Line access
Line access...

Page 143

Terminals&Sets / 143
P0603539  02Compact ICS 6.1 Installer Guide
Line assignment
This setting allows you to assign physical trunks and target lines to each 
telephone. Target lines are assigned and removed in the same manner as 
other lines. Press 
≠ and enter the line number. 
Press 
CHANGE to change the setting for each line: Unassigned, 
Appr&Ring, Appr only, or Ring only. Broadcast ring group ability is 
possible with multiple target line assignment across a group of telephones. 
Tip - Press SCAN to...

Page 144

144 / Terminals&Sets
Compact ICS 6.1 Installer GuideP0603539  02
Appearances
This setting only applies for direct  inward dial (DID) digits mapped onto 
target lines (061-086).
The Norstar system can handle simultaneous calls to a telephone assigned 
with multiple target line appearances . The number of target line 
appearances depends on the line assignment setting , which include: 
Appr&Ring, Ring only, Appr  only.
If Appr&Ring or Appr only is chosen, you can have as many simultaneous 
DID calls as...

Page 145

Terminals&Sets / 145
P0603539  02Compact ICS 6.1 Installer Guide
Prime line
This setting assigns a prime line to the telephone. A prime line is the first 
line that is automatically selected when the handset is lifted. 
Press 
CHANGE to select the setting: None, a line number, 
Pool (A to C), or I/C (intercom). Only assigned lines and line pools appear.
Tip - An assigned prime line is not associated with the 
assignment of a prime telephone.
An external line must be assigned to the telephone in 
Line...

Page 146

146 / Terminals&Sets
Compact ICS 6.1 Installer GuideP0603539  02
Intercom keys
This setting assigns the number of intercom buttons to a telephone. 
Intercom buttons can provide a telephone with access to internal lines and 
line pools. Press 
CHANGE to select the setting: 0, 1, 2, 3, 4, 5, 6, 7, or 8.
Answer DNs
Calls for other Norstar telephones can appear and be answered at the 
telephone being programmed. The DNs of the other telephones are referred 
to as Answer DNs. You can assign up to eight Answer...

Page 147

Terminals&Sets / 147
P0603539  02Compact ICS 6.1 Installer Guide
.
OLI #
When you make an outgoing call on a BRI line, the Call Display 
information which appears on the telephone you are calling is usually 
based on the first Network DN associated with the service profile identifier 
(SPID) and line.
If the SPID and line have more than one Network DN, you can program a 
DN to use a Network DN other than the first one for the outgoing Call 
Display information. When you program the alternate Network DN...

Page 148

148 / Terminals&Sets
Compact ICS 6.1 Installer GuideP0603539  02
Capabilities
Settings that control how the system interacts with individual telephones 
and the calls they receive are found in 
Capabilities. The default settings 
are given in bold in the table below.
SettingDescriptionOptions
Fwd no answer
Fwd toRedirect all incoming calls to this 
telephone when this telephone does not 
answer.Enter DN
None
Forward delaySelect the number of rings before an 
unanswered call is forwarded.2, 3, 4, 6, 10...

Page 149

Terminals&Sets / 149
P0603539  02Compact ICS 6.1 Installer Guide
For more programming information, see the Compact ICS 6.1 System 
Coordinator Guide.
HotlineSelect whether a telephone number will 
be dialed automatically when a  user lifts 
the handset or presses the handsfree 
key.Intrnl, Extrnl 
(enter DN), None
Intrnl #Appears if Hotline is IntrnlEnter DN, None
Extrnl #Appears if ExtrnlNone, 

Aux. ringerSelect whether an auxiliary ringer (if 
installed) will ring for incoming calls at 
this...

Page 150

150 / Terminals&Sets
Compact ICS 6.1 Installer GuideP0603539  02
ATA settings
ATA ans timer
A timer can be used to administer a delay between the last digit you dial on 
a device connected to an analog terminal adapter (ATA) and when the 
system begins to send out tones (DTMF or modem)  on the outgoing line 
without capturing and interpreting them. To change the delay time, press 
CHANGE to select the setting (in seconds): ATA ans timer: 3, 5, 7, or 10.
If the DN you are programming is the internal...