0005 - Extension Circuit Type
 Sorts Data Updates CEU Can be Copied
Description
 124i Not available — circuit types auto-
ID. This option is in the 124i PC
Program for reference only. 384i Available
INUse Program 0005 - Extension Circuit Type Setup to set the circuit type for the device at each extension port
(1-256). The following table shows the available circuit types:
This device . . .Use this circuit type . . .
Not set 0
Keyset 1
Keyset with DCI Module 2
500/2500 set 3
3-DCI Module 4
3-ACI Module...

Page 662

Type:
4. Enter the circuit type for the port selected and press HOLD.
Order:
5. Refer to the Understanding Port Assignments table below and enter the Order Number.
STA PORT No?
6. Enter the extension port number you want to program and press HOLD.
OR
Press HOLD to exit program.
Setting the Installation Order Number
Use the following table when assigning the Order Number in step 5 above. Also keep the following in mind:
•The system capacity is 384 physical ports
•The total of extensions ports, trunk...

Page 663

Understanding Port Assignments
Device Physical Port Circuit Type Installation 
Order NumberSoftware Port System Capacity
3-ACI Module Same as station
port into which
3-ACI is plugged511
2
through
641
2
3
4
5
6
190
191
192
Used in Series
1300 Programs64
192 separate ACI
ports, with 3
ports on each
3-ACI
VAU Module Same as station
port into which
VAU is plugged8 Assign Order 1
to the Main VAU
Module
Assign Order 2
to the Plug-in
Expansion Board2-256 1 Main VAU
Module and
1 Plug-in
Expansion Board
2-OPX...

Page 664

0006 - Slot Control
 Sorts Data Updates CEU Can be Copied
Description
 124i Not available 384i Available from telephone
programming only.
INUse Program 0006 - Slot Control to close (turn off) or delete (uninstall) circuit boards (slots 1-25). 
Close lets you block a PCB (just like placing the PCB switch down). Once closed, none of the ports on the PCB
can be used for new calls. Existing calls, however, are not torn down. You can cancel the close command by
placing the PCB switch to the up position....

Page 665

0007 - System Report Port Setup
  Sorts Data   Updates CEU   Can be Copied
Description
 124i The 124i system has an enhanced
system report. This program assigns
the system report printer and
additional report options. Items 2-6
are available from telephone
programming only. 384i Assigns only the system report
printer.
IN384i
Use Program 0007 - System Report Port Setup to indicate to which DCI software port (1-288) you have connected
the system printer. After selecting the DCI port, you can also use...

Page 666

PCB Board Information (Item 3)
>     03/16/94 00:41
Main Software Version : 1.1F
------------------------------------------------------------------------------
CPRU type is BASIC. Backup battery O.K.
- Board install condition -
            1       2       3       4       5       6       7       8
Unit 1  +--DSTU-+-------+-------+--ASTA-+-------+--ATRU-+--PGDU-+--DTDU-+
Version                            0.05            1.00            0.00
Option                                                     DDDD...

Page 667

Program 0007 – 124i System Report Port Setup (Cont’d)
This menu item . . . Lets you . . .  With this data . . .
1
5 - Printout Only
Station and DCI
InformationHave the printer designated in Item 1
output just the Station and DCI section
of the system report (see below).1 + HOLD for Yes
OR
HOLD to cancel without changing
For each station port (1-72), this section shows:
– The cabinet number, slot and station location on PCB  (e.g., 1-1-1 is the Main
  cabinet, slot one, first station on the PCB).
–...

Page 668

- DCI port -
 No. Port Kind     Dial    No. Port Kind     Dial    No. Port Kind     Dial
  1 1-1-1 built-in 601     25 Not assigned           49 Not assigned
  2 Not assigned           26 Not assigned           50 Not assigned
  3 Not assigned           27 Not assigned           51 Not assigned
  4 Not assigned           28 Not assigned           52 Not assigned
  5 Not assigned           29 Not assigned           53 Not assigned
  6 Not assigned           30 Not assigned           54 Not assigned
  7...

Page 669

- VAU port -
       Unit Slot Port
Master   Not assigned
Slave    Not assigned
- Door phone port -    - Speaker port -       - Sensor port -
No.Unit Slot Port      No.Unit Slot Port      No.Unit Slot Port Kind
 1    1    7    1      *1    1    7    1       1    1    7    5  Alarm
 2    1    7    2      *2    1    7    2       2    1    7    6  Alarm
 3    1    7    3      *3    1    7    3       3    1    7    7  Alarm
 4    1    7    4      *4    1    7    4       4    1    7    8  Alarm
 5  Not...

Page 670

Telephone Programming Instructions
To enter data for Program 0007 (System Report Port Setup):
(384i Only)
1. Enter the programming mode.
2. 0007 + HOLD
Print Port:
3. Enter the system report printer DCI port number (System Report Port )
Print?(Yes:1)
4. Press 1 + HOLD to print the report.
OR
Press HOLD to skip printing.
(124i Only)
1. Enter the programming mode.
2. 0007 + HOLD
Menu No?
3. Enter the menu number you want to program (1-6) + HOLD
4.For Item 1
Enter the system report printer DCI port number +...