0008 - Alarm Report Port Setup
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Available. 384i Available.
INUse Program 0008 - Alarm Report Port Setup to set the options for the alarm report. This program has 5 sepa-
rate menu options (see the following chart). Items 2-4 are available only from the telephone programming. To
view the alarm report from within the PC program, refer to 0092 - View Alarm Report. To upload the alarm re-
port from the system to the PC program, use PC program...

Page 672

Telephone Programming Instructions
To enter data for Program 0008 (Alarm Report Port Setup):
1. Enter the programming mode.
2. 0008 + HOLD.
Menu No?
3. Select the menu for the item you want to program + HOLD.
4. Refer to the chart above (Program 0008 Menu Items) and enter data as required.
5. Repeat from step 3 to program additional menu items.
0000 - Maintenance Options
0008 - Alarm Report Port Setup
636   PROGRAMMING 92000SWG08  Issue 1-0 

Page 673

0009 - Loop Back Testing
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Not available. 384i Available from telephone
programming only.
INUse Program 0009 - Loop Back Testing to perform a loop back diagnostic test on telephones and system
PCBs. This program has 9 separate menu options (see the following chart).
Program 0009 Menu Items
This menu item . . . Lets you . . .  With this data . . . 
1
1 - Analog Set
Loopback 
(CEU to ASTU PCB)Perform a loopback test from the CEU
to the selected...

Page 674

Telephone Programming Instructions
To enter data for Program 0009 (Loop Back Testing):
1. Enter the programming mode.
2. 0009 + HOLD
Menu No?
3. Select the menu for the item you want to program + HOLD.
4. Refer to the chart above (Program 0009 Menu Items) and enter data as required.
5. Repeat from step 3 to program additional menu items.
0000 - Maintenance Options
0009 - Loop Back Testing
638   PROGRAMMING 92000SWG08  Issue 1-0 

Page 675

0010 - Alarm LED Setup
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Not Available. The CPRU PCB does
not have alarm LEDs. 384i Available.
INUse Program 0010 - Alarm LED Setup to assign a status to each of the system alarms. You can designate an
alarm as Major (MAJ) or Minor (MIN). This determines which alarm LED indicates on the CPRU PCB and
CEU if the alarm occurs. In addition, you can also assign an alarm to Alarm LEDs 1-5 on the CPRU PCB (AL1-
AL5). For example, designate alarm 0105...

Page 676

Telephone Programming Instructions
To enter data for Program 0010 (Alarm LED Setup):
1. Enter the programming mode.
2. 0010 + HOLD
Alarm No?
3. Enter the number of the alarm you want to program + HOLD
Type:
4. Enter the type of alarm + HOLD
1 = Major alarm
2 = Minor alarm
Level:
5. Enter the number of the CPRU LED assigned to the alarm (1-5 for AL1-AL5) + HOLD
0000 - Maintenance Options
0010 - Alarm LED Setup
640   PROGRAMMING 92000SWG08  Issue 1-0 

Page 677

0011 - Alarm Display Telephone
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Available. System has 72 station
ports (1-72). 384i Available. System has 256 station
ports (1-256).
INUse Program 0011 - Alarm Display Telephone to assign the display keyset port that should receive system
alarms. The keyset you select will display an alarm if:
•The battery on the CPRU PCB is low
•The periodic maintenance program encounters a disk error (384i only)
•The periodic program disk maintenance fails...

Page 678

0012 - Remote Service Center Phone Number
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Currently not implemented. 384i Currently not implemented.
INUse Program 0012 - Remote Service Center Phone Number to define the Remote Service Center telephone
number. This is the number the system dials for Automatic Fault Reporting. The number can be up to 24 digits
long, using the characters 0-9, # and *.
This option is currently not used.
Conditions
None
Feature Cross Reference
None
Telephone...

Page 679

0013 - Remote Service Center Trunk Group
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Currently not implemented. 384i Currently not implemented.
INProgram 0013 - Remote Service Center Trunk Group defines the trunk group used when placing calls to the
Service Center for Automatic Fault Reporting.
This option is currently not used.
Conditions
None
Feature Cross Reference
None
Telephone Programming Instructions
To enter data for Program 0013 (Remote Service Center Trunk Group):
1. Enter...

Page 680

0014 - Remote Service Center User’s Data
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Currently not implemented. 384i Currently not implemented.
INUse Program 0014 - Remote Service Center User’s Data to define the site identification data sent to the
Service Center when automatically reporting a fault. The data can consist of alphanumeric characters up to
16 digits long.
This option is currently not used.