0008 - Alarm Report Port Setup Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0008 - Alarm Report Port Setup to set the options for the alarm report. This program has 5 sepa- rate menu options (see the following chart). Items 2-4 are available only from the telephone programming. To view the alarm report from within the PC program, refer to 0092 - View Alarm Report. To upload the alarm re- port from the system to the PC program, use PC program...
Page 672
Telephone Programming Instructions To enter data for Program 0008 (Alarm Report Port Setup): 1. Enter the programming mode. 2. 0008 + HOLD. Menu No? 3. Select the menu for the item you want to program + HOLD. 4. Refer to the chart above (Program 0008 Menu Items) and enter data as required. 5. Repeat from step 3 to program additional menu items. 0000 - Maintenance Options 0008 - Alarm Report Port Setup 636 PROGRAMMING 92000SWG08 Issue 1-0
Page 673
0009 - Loop Back Testing Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available from telephone programming only. INUse Program 0009 - Loop Back Testing to perform a loop back diagnostic test on telephones and system PCBs. This program has 9 separate menu options (see the following chart). Program 0009 Menu Items This menu item . . . Lets you . . . With this data . . . 1 1 - Analog Set Loopback (CEU to ASTU PCB)Perform a loopback test from the CEU to the selected...
Page 674
Telephone Programming Instructions To enter data for Program 0009 (Loop Back Testing): 1. Enter the programming mode. 2. 0009 + HOLD Menu No? 3. Select the menu for the item you want to program + HOLD. 4. Refer to the chart above (Program 0009 Menu Items) and enter data as required. 5. Repeat from step 3 to program additional menu items. 0000 - Maintenance Options 0009 - Loop Back Testing 638 PROGRAMMING 92000SWG08 Issue 1-0
Page 675
0010 - Alarm LED Setup Sorts Data Updates CEU Can be Copied Description 124i Not Available. The CPRU PCB does not have alarm LEDs. 384i Available. INUse Program 0010 - Alarm LED Setup to assign a status to each of the system alarms. You can designate an alarm as Major (MAJ) or Minor (MIN). This determines which alarm LED indicates on the CPRU PCB and CEU if the alarm occurs. In addition, you can also assign an alarm to Alarm LEDs 1-5 on the CPRU PCB (AL1- AL5). For example, designate alarm 0105...
Page 676
Telephone Programming Instructions To enter data for Program 0010 (Alarm LED Setup): 1. Enter the programming mode. 2. 0010 + HOLD Alarm No? 3. Enter the number of the alarm you want to program + HOLD Type: 4. Enter the type of alarm + HOLD 1 = Major alarm 2 = Minor alarm Level: 5. Enter the number of the CPRU LED assigned to the alarm (1-5 for AL1-AL5) + HOLD 0000 - Maintenance Options 0010 - Alarm LED Setup 640 PROGRAMMING 92000SWG08 Issue 1-0
Page 677
0011 - Alarm Display Telephone Sorts Data Updates CEU Can be Copied Description 124i Available. System has 72 station ports (1-72). 384i Available. System has 256 station ports (1-256). INUse Program 0011 - Alarm Display Telephone to assign the display keyset port that should receive system alarms. The keyset you select will display an alarm if: •The battery on the CPRU PCB is low •The periodic maintenance program encounters a disk error (384i only) •The periodic program disk maintenance fails...
Page 678
0012 - Remote Service Center Phone Number Sorts Data Updates CEU Can be Copied Description 124i Currently not implemented. 384i Currently not implemented. INUse Program 0012 - Remote Service Center Phone Number to define the Remote Service Center telephone number. This is the number the system dials for Automatic Fault Reporting. The number can be up to 24 digits long, using the characters 0-9, # and *. This option is currently not used. Conditions None Feature Cross Reference None Telephone...
Page 679
0013 - Remote Service Center Trunk Group Sorts Data Updates CEU Can be Copied Description 124i Currently not implemented. 384i Currently not implemented. INProgram 0013 - Remote Service Center Trunk Group defines the trunk group used when placing calls to the Service Center for Automatic Fault Reporting. This option is currently not used. Conditions None Feature Cross Reference None Telephone Programming Instructions To enter data for Program 0013 (Remote Service Center Trunk Group): 1. Enter...
Page 680
0014 - Remote Service Center User’s Data Sorts Data Updates CEU Can be Copied Description 124i Currently not implemented. 384i Currently not implemented. INUse Program 0014 - Remote Service Center User’s Data to define the site identification data sent to the Service Center when automatically reporting a fault. The data can consist of alphanumeric characters up to 16 digits long. This option is currently not used. Conditions None Feature Cross Reference None Telephone Programming Instructions To...