Page 701
Telephone Programming Instructions To enter data for Program 0112 (Intercom and Alarm Ring Tone): 1. Enter the programming mode. 2. 0112 + HOLD Pattern No? 3. To set the Intercom ring tone, enter 1 + HOLD OR To set the External Alarm Sensor ring tone, enter 2 + HOLD Type No? 4. Enter the number of the Type (1-3) you want to program + HOLD 1 = High, 2 = Middle and 3 = Low Frequency No? 5. Enter the frequency you want to program (1-3) + HOLD Refer to the Intercom and Alarm Ring Tones chart if necessary. 6....
Page 702
0114 - Analog Trunk (ATRU PCB) Timers (Part A) Sorts Data ✔ Updates CEU Can be Copied Description 124i Available. System has 52 trunk ports (1-52). 384i Available. System has 128 trunk ports (1-128). INUse Program 0114 - Analog Trunk (ATRU PCB) Timers (Part A) to set the critical timing for the Analog Trunk (ATRU) PCB. The system uses the entries you make in this program for all ATRU PCBs. Refer to the fol- lowing chart for a description of each timer, its range and default setting. For additional...
Page 703
Analog Trunk (ATRU PCB) Timers Item (Timer No.)Description Range Default Item 720 PPS DP Make Time (DP-Make [20]) For 20 PPS Dial Pulse trunks, this sets the digit make time.1-255 (4-1020 mS in 4 mS steps)4 (16 mS) Item 820 PPS DP Interdigit Time (DP-Intdt [20]) For 20 PPS Dial Pulse trunks, this sets the interdigit time (i.e., the quiet time between DP digits).1-255 (100-25500 mS in 100 mS steps)5 (500 mS) Item 9Flash (Hooking 1) This sets the flash (Hooking 1) duration for analog trunk calls. See...
Page 704
Conditions None Feature Cross Reference None Telephone Programming Instructions To enter data for Program 0114 (Analog Trunk Timers [Part A]): 1. Enter the programming mode. 2. 0114 + HOLD Item No? 3. Enter the number of the timer (Item) you want to program + HOLD 4. Enter the desired timer duration + HOLD 5. Repeat from step 3 to make additional entries OR HOLD to exit Ring Off Ring On Set trunk for Immediate or Extended Ring Detect in Program 0901 Item 2. Program 0114 Item 15Program 0114 Item 17...
Page 705
0115 - Analog Station (ASTU) Timers Sorts Data Updates CEU Can be Copied Description 124i Available (except for Item 9). 384i Available. INUse Program 0115 - Analog Station (ASTU) Timers to set various timing parameters for the Analog Station (ASTU) PCB. The system uses the entries you make in this program for all ASTU PCBs. Refer to the following chart for a description of each timer, its range and default setting. Analog Station (ASTU PCB) Timers Item (Timer No.)Description Range Default Item...
Page 706
Telephone Programming Instructions To enter data for Program 0115 (Analog Station Timers): 1. Enter the programming mode. 2. 0115 + HOLD Item No? 3. Enter the timer (Item) you want to program + HOLD 4. Enter the desired timer duration + HOLD 0100 - Basic Hardware Setup (Part A) 0115 - Analog Station (ASTU) Timers 670 PROGRAMMING 92000SWG08 Issue 1-0
Page 707
0116 - Tone Detection Setup Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. - Requires Base 2.13, EXCPRU 2.18 or higher.- Requires system software 3.04 or higher. INUse this program to set the criteria for DTMF signaling, dial tone detection, and dial, busy and ringback tones. The system uses this program to filter out invalid tones from connected telco or PBX. For example, an incoming DTMF tone can only be accepted as valid by the system if it meets the...
Page 708
DTMF and Dial Tone Detection Setup Item Description Range Default Item 8Twist Level for OPXs (TWISTLEV[INT]) The level of the two tones in a DTMF burst cannot vary by more than this setting. If variance in the tone levels exceeds this setting, the system considers the tone invalid.1-6 (+ 5 to + 10 in 1 dB steps)6 (+ 10 dB) Item 9Guard Time for Trunks (GUARDLEV[EXT]) After seizing an outgoing trunk, the system waits this interval before outputting DTMF digits.1-8 (10-38 mS in 4 mS steps)4 (22 mS) Item...
Page 709
DTMF and Dial Tone Detection Setup Item Description Range Default Item 18Signal to Noise Ratio for OPX Circuits (S/N[INT]) This option sets the ratio of dial tone to the OPX circuit’s idle channel noise.1-3 (1=-15 dB, 2=-20 dB, 3=-25dB)2 (-20 dB) Dial, Busy and Ringback Tone Criteria For Items 19-32 below, make an entry for each of the three tone types. Each tone type has two frequencies: Tone A and Tone B. Tone Type 1 = RBT (Ringback Tone) Tone Type 2 = BT (Busy Tone) Tone Type 3 = SDT (Standard...
Page 710
DTMF and Dial Tone Detection Setup Item Description Range Default Item 26Dial Tone 1 Minimum Off Time for Tone B (DTOF_MIN_B) For the tone type you are programming, set the Tone B cycle minimum off time. If the cycle off time is less than this interval, the tone is invalid.1-255 (20-5100 mS in 20 mS steps)RBT=0 BT=0 SDT=0 Item 27Dial Tone 1 Maximum On Time for Tone A (DTOF_MAX_A) For the tone type you are programming, set the Tone A cucle maximum off time. If the cycle off time is greater than this...