Page 701

Telephone Programming Instructions
To enter data for Program 0112 (Intercom and Alarm Ring Tone):
1. Enter the programming mode.
2. 0112 + HOLD
Pattern No?
3. To set the Intercom ring tone, enter 1 + HOLD
OR
To set the External Alarm Sensor ring tone, enter 2 + HOLD
Type No?
4. Enter the number of the Type (1-3) you want to program + HOLD
1 = High, 2 = Middle and 3 = Low
Frequency No?
5. Enter the frequency you want to program (1-3) + HOLD
Refer to the Intercom and Alarm Ring Tones chart if necessary.
6....

Page 702

0114 - Analog Trunk (ATRU PCB) Timers (Part A)
 Sorts Data
✔  Updates CEU   Can be Copied
Description
 124i Available. System has 52 trunk ports
(1-52). 384i Available. System has 128 trunk
ports (1-128).
INUse Program 0114 - Analog Trunk (ATRU PCB) Timers (Part A) to set the critical timing for the Analog
Trunk (ATRU) PCB. The system uses the entries you make in this program for all ATRU PCBs. Refer to the fol-
lowing chart for a description of each timer, its range and default setting. For additional...

Page 703

Analog Trunk (ATRU PCB) Timers
Item
(Timer No.)Description Range Default
Item 720 PPS DP Make Time (DP-Make [20])
For 20 PPS Dial Pulse trunks, this sets the digit make
time.1-255 (4-1020
mS in 4 mS
steps)4 (16 mS)
Item 820 PPS DP Interdigit Time (DP-Intdt [20])
For 20 PPS Dial Pulse trunks, this sets the interdigit
time (i.e., the quiet time between DP digits).1-255
(100-25500
mS in 100 mS
steps)5 (500 mS)
Item 9Flash (Hooking 1) 
This sets the flash (Hooking 1) duration for analog
trunk calls. See...

Page 704

Conditions
None
Feature Cross Reference
None
Telephone Programming Instructions
To enter data for Program 0114 (Analog Trunk Timers [Part A]):
1. Enter the programming mode.
2. 0114 + HOLD
Item No?
3. Enter the number of the timer (Item) you want to program + HOLD
4. Enter the desired timer duration + HOLD
5. Repeat from step 3 to make additional entries
OR
HOLD to exit
Ring Off Ring On
Set trunk for Immediate or Extended
Ring Detect in Program 0901 Item 2.
Program 0114 Item 15Program 0114 Item 17...

Page 705

0115 - Analog Station (ASTU) Timers
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Available (except for Item 9). 384i Available.
INUse Program 0115 - Analog Station (ASTU) Timers to set various timing parameters for the Analog Station
(ASTU) PCB. The system uses the entries you make in this program for all ASTU PCBs. Refer to the following
chart for a description of each timer, its range and default setting.
Analog Station (ASTU PCB) Timers
Item
(Timer No.)Description Range Default
Item...

Page 706

Telephone Programming Instructions
To enter data for Program 0115 (Analog Station Timers):
1. Enter the programming mode.
2. 0115 + HOLD
Item No?
3. Enter the timer (Item) you want to program + HOLD
4. Enter the desired timer duration + HOLD
0100 - Basic Hardware Setup (Part A)
0115 - Analog Station (ASTU) Timers
670   PROGRAMMING 92000SWG08  Issue 1-0 

Page 707

0116 - Tone Detection Setup
  Sorts Data   Updates CEU   Can be Copied
Description
 124i Available. 384i  Available.
- Requires Base 2.13, EXCPRU 2.18
or higher.- Requires system software 3.04 or
higher.
INUse this program to set the criteria for DTMF signaling, dial tone detection, and dial, busy and ringback tones.
The system uses this program to filter out invalid tones from connected telco or PBX. For example, an incoming
DTMF tone can only be accepted as valid by the system if it meets the...

Page 708

DTMF and Dial Tone Detection Setup
Item Description Range Default
Item 8Twist Level for OPXs (TWISTLEV[INT])
The level of the two tones in a DTMF burst cannot vary
by more than this setting. If variance in the tone levels
exceeds this setting, the system considers the tone invalid.1-6 (+ 5 to +
10 in 1 dB
steps)6 (+ 10 dB)
Item 9Guard Time for Trunks (GUARDLEV[EXT])
After seizing an outgoing trunk, the system waits this
interval before outputting DTMF digits.1-8 (10-38 mS
in 4 mS steps)4 (22 mS)
Item...

Page 709

DTMF and Dial Tone Detection Setup
Item Description Range Default
Item 18Signal to Noise Ratio for OPX Circuits (S/N[INT])
This option sets the ratio of dial tone to the OPX circuit’s
idle channel noise.1-3 (1=-15
dB, 2=-20 dB,
3=-25dB)2 (-20 dB)
Dial, Busy and Ringback Tone Criteria
For Items 19-32 below, make an entry for each of the three tone types. Each tone type has two
frequencies: Tone A and Tone B.
  Tone Type 1 = RBT (Ringback Tone)
  Tone Type 2 = BT (Busy Tone)
  Tone Type 3 = SDT (Standard...

Page 710

DTMF and Dial Tone Detection Setup
Item Description Range Default
Item 26Dial Tone 1 Minimum Off Time for Tone B
(DTOF_MIN_B)
For the tone type you are programming, set the Tone B
cycle minimum off time. If the cycle off time is less than
this interval, the tone is invalid.1-255
(20-5100 mS
in 20 mS steps)RBT=0
BT=0
SDT=0
Item 27Dial Tone 1 Maximum On Time for Tone A
(DTOF_MAX_A)
For the tone type you are programming, set the Tone A
cucle maximum off time. If the cycle off time is greater
than this...