Nitsuko 124i/384i Software Manual
Here you can view all the pages of manual Nitsuko 124i/384i Software Manual. The Nitsuko manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 731
9. Repeat from step 3 to make additional entries OR HOLD to exit 0100 - Basic Hardware Setup (Part A) 0131 - Unsupervised Conf. CODEC Gain Setup 92000SWG08 Issue 1-0 PROGRAMMING 695
Page 732
0132 - DID Trunk Timers Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0132 - DID Trunk Timers to set the Direct Inward Dialing (DID) Trunk Timers. The settings you make in this program affect all DID trunks in all Tenant Groups. Make sure the DID Trunk Timers are compatible with you local telco. Refer to the following chart for a description of each timer, its range and default setting. DID Trunk Timers Item Description Range Default Item 1Loop...
Page 733
Telephone Programming Instructions To enter data for Program 0132 (DID Trunk Timers): 1. Enter the programming mode. 2. 0132 + HOLD Item No? 3. Enter the number of the timer you want to program (1-5) + HOLD (timer): 4. Enter data for the timer selected + HOLD Refer to the chart above for the timer settings. Item No? 5. Return to step 3 to program another timer. OR HOLD to exit. 0100 - Basic Hardware Setup (Part A) 0132 - DID Trunk Timers 92000SWG08 Issue 1-0 PROGRAMMING 697
Page 734
0133 - Tie Line Timers Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INProgram 0133 - Tie Line Timers sets various timers for Tie Lines. The settings you make in this program af- fect all tie lines in all Tenant Groups. Be sure to set the Tie Line Timers for compatibility with the local telco. Re- fer to the following chart for a description of each timer, its range and default setting. Tie Line Timers Timer Description Range Default Item 1Answer Signal...
Page 735
Tie Line Timers Timer Description Range Default Item 13Wink Duration Time1-255 (8-2040 mS in 8 mS steps) 25 (200 mS) Item 14Incoming Wink Send Time1-255 (100-25500 mS in 100mS steps)10 (1000mS) Item 15Wink Receive Maximum Time (Seizure)1-255 (100-25500 mS in 100mS steps) 48 (4800 mS) Item 16Wink Receive Minimum Time (Receive)1-255 (8-2040 mS in 8 mS steps)12 (96 mS) Item 17Wink Receive Maximum Time (Receive)1-255 (8-2040 mS in 8 mS steps)44 (352mS) Item 18Dial Pulse Make Minimum Time (Receive)1-255...
Page 736
Refer to the chart above for the timer settings. Item No? 5. Return to step 3 to program another timer. OR HOLD to exit. 0100 - Basic Hardware Setup (Part A) 0133 - Tie Line Timers 700 PROGRAMMING 92000SWG08 Issue 1-0
Page 737
0135 - Analog Trunk (ATRU PCB) Timers (Part B) Sorts Data ✔ Updates CEU Can be Copied Description 124i Available. System has 52 trunk ports (1-52). 384i Available. System has 128 trunk ports (1-128). INUse Program 0135 - Analog Trunk (ATRU PCB) Timers (Part A) to set critical timing for the Analog Trunk (ATRU) PCB. The system uses the entries you make in this program for all ATRU PCBs. Refer to the following chart for a description of each timer, its range and default setting. For additional ATRU...
Page 738
Telephone Programming Instructions To enter data for Program 0135 (Analog Trunk Timers [Part B]): 1. Enter the programming mode. 2. 0135 + HOLD Item No? 3. Enter the number of the timer (Item) you want to program + HOLD 4. Enter the desired timer duration + HOLD 5. Repeat from step 3 to make additional entries OR HOLD to exit 0100 - Basic Hardware Setup (Part A) 0135 - Analog Trunk (ATRU PCB) Timers (Part B) 702 PROGRAMMING 92000SWG08 Issue 1-0
Page 739
0136 - T1 Trunk Timers Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0136 - T1 Trunk Timers to set various timers for T1 Trunks. Refer to the following chart for a description of each timer, its range and default setting. T1 Trunk Timers Timer Description Range Default Item 1Tie Line Answer Signal Time1-255 (4-1020 mS in 4 mS steps) 15 (60 mS) Item 2OPX Trunk Answer Signal Time1-255 (4-1020 mS in 4 mS steps15 (60 mS) Item 3Clear Signal (Open...
Page 740
T1 Trunk Timers Timer Description Range Default Item 13Ringing Signal Stop Detection Minimum Time for Loop Start Trunks1-255 (100-25500 mS in 100mS steps)50 (5 S) Item 14Ringing Signal Stop Detection Minimum Time for Ground Start Trunks1-255 (100-25500 mS in 100mS steps)10 (1 S) Item 15Open Loop Time for DID Trunks1-255 (100-25500 mS in 100mS steps) 6 (600 mS) Item 16Close Loop Time for Loop Start Trunks1-255 (4-1020 mS in 4 mS steps)18 (72 mS) Item 17Close Loop Time for DID Trunks1-255 (4-1020 mS...