    							ND-45857 (E) CHAPTER 3
    Addendum-001 Page 43
    AUGUST, 1998 Revision 3.1
    INSTALLATION
    4.2.1 Mounting BRI Card
    STEP 1: On the BRI (PN-BRTA/2BRTC) card, set the switches as shown in Figure 3-13.
    Figure 3-13   Switch Settings on the BRI Card (PN-BRTA)
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    RUN
    SET THE KNOB TO MATCH THE
    AP NO. (04-15) TO BE SET BY 
    CM05.SENS
    SENS
    MB
    SW1
    B1
    B2
    D
    ALM
    SW0
    SW1SW0 MB
    UP
    1 234ON
    SEE Table 3-5. :  
    POSITION TO BE SET
    12ON
    SEE Table 3-6
    .
    •   PN-BRTA 
    						
    							CHAPTER 3 ND-45857 (E)
    Page 44 Addendum-001
    Revision 3.1 AUGUST, 1998
    INSTALLATION
    Table 3-5  Switch Settings for SW0-2 and SW0-3 on the BRI Card (PN-BRTA)
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION column
    indicate the standard setting of the switch. When the switch is not set as shown by the figure and   , the set-
    ting of the switch varies with the system concerned.
    Table 3-6  Switch Settings for SW1 on the BRI Card (PN-BRTA)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW1 (Dip SW)
    1For terminating the transmitting side 
    of channels B1 and B2 with 100 ohms.
    OFFTo remove the terminating resistor on 
    the transmitting side of channels B1 
    and B2.
    2For terminating the receiving side of 
    channels B1 and B2 with 100 ohms.
    OFFTo remove the terminating resistor on 
    the receiving side of channels B1 and 
    B2.
    BRI 11
    CONDITIONSSW No. of BRI
    REMARKS
    When only one BRI is
    provided
    When more than one
    BRI is providedOFF ONTo send a clock signal to 
    PLO0 of the MP card.
    To send a clock signal via 
    BRI1 to PLO1 of the MP/
    PLO card, when a clock 
    signal via BRI0 is not 
    supplied due to a trans-
    mission line failure.
    (The clock supply route 0 
    via BRI0 is automati-
    cally changed to the clock 
    supply route 1 via BRI1.)
    SW0-3 SW0-2
    BRI 0
    ON ON
    SW0-3 SW0-2
    BRI 1
    ON OFF
    SW0-3 SW0-2
    BRI 2
    OFF ON
    SW0-3 SW0-2
    ON ON
    12 ON
    ON
    ON 
    						
    							ND-45857 (E) CHAPTER 3
    Addendum-001 Page 44-1
    AUGUST, 1998 Revision 3.1
    INSTALLATION
    Figure 3-13-1  Switch Settings on the BRI Card (PN-2BRTC)
    RU N
    SET THE KNOB TO MATCH THE
    AP NO. (04-15) TO BE SET BY 
    CM05.
    SENS
    MB
    SW0
    D1
    ALM1
    B20
    B10
    SW10SW11 MB
    UP
    4
    ON
    SEE Note and Table 3-6-2.
    :  POSITION TO BE SET
    21
    ON
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions RequiredSENS
    SW11
    3
    2
    1
    SW10
    FOR NO.1 CIRCUIT
    SEE Table 3-6-1.
    21
    ON
    FOR NO.0 CIRCUIT
    SEE Table 3-6-1. SW0
    D0
    ALM0
    B21
    B11
    •  PN-2BRTC 
    						
    							CHAPTER 3 ND-45857 (E)
    Page 44-2 Addendum-001
    Revision 3.1 AUGUST, 1998
    INSTALLATION
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION column indi-
    cate the standard setting of the switch. When the switch is not set as shown by the figure and  , the setting
    of the switch varies with the system concerned.
    Note:The system can supply clock signals from two clock supply routes.
    In normal condition, the system synchronizes to the clock signals supplied on the PLO 0 of MP card via
    the Back Wiring Board, and if the clock signals are failed, the clock supply route takes over to PLO1 au-
    tomatically.
    Table 3-6-1 Switch Settings for SW0 and SW10 on the BRI Card  (PN-2BRTC)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW0, SW10
    (Dip SW)
    1For terminating the transmitting side
    of channels B1 and B2 with 100 ohms.
    OFFTo remove the terminating resistor on
    the transmitting side of channels B1
    and B2.
    2For terminating the receiving side of
    channels B1 and B2 with 100 ohms.
    OFFTo remove the terminating resistor on
    the receiving side of channels B1 and
    B2.
    Table 3-6-2  Switch Setting for SW11-2 and SW11-3 on the BRI Card (PN-2BRTC)
    BRI  0 BRI  1 BRI  2 BRI  11
    REMARKSSW11 
    -2SW11 
    -3SW11 
    -2SW11 
    -3SW11 
    -2SW11 
    -3SW11 
    -2SW11 
    -3
    When one BRI is 
    provided.ON ONThe clock signals are supplied to the
    PLO through No. 0 circuit of the BRI.
    If the clock supply route of No. 0 cir-
    cuit is failed, the clock supply route of
    No. 1 circuit takes over automatical-
    ly.
    When more than 
    one BRI is pro-
    vided.ON ON ON OFF OFF ON OFF ONThe system can supply the clock
    signals from BRI 0 or BRI 1. The
    system is synchronized to the BRI 0
    clock signals normally, and if both
    No. 0 circuit clock supply route and
    No. 1 circuit clock supply route is
    failed, the BRI 1 takes over.
    1ON2
    ON
    ON
    No. of
    BRI
    SW
    CONDITIONS 
    						
    							ND-45857 (E) CHAPTER 3
    Page 45
    Revision 3.0
    INSTALLATION
    STEP 2: Mount the BRI card in AP slots on PIM0-PIM7.
    After mounting the card, set the SENS switch to match an unequipped slot number in CM05. Set the
    MB switch to down position to put the card in service. For details on mounting locations, refer to the
    Circuit Card Manual.
    Figure 3-14   Mounting Location of BRI Card
    BRI
    CARDBUILT-IN BATTERY
    • Mount BRI card in the AP slots (AP0-AP6).
    • Set the SENS switch on the BRI card to match an unequipped slot number in CM05 as shown be-
    low.
    SLOT NUMBER
    SWITCH SETTING VALUE
    04
    4
    05
    5
    06
    6
    07
    7
    08
    8
    09
    9
    10
    A
    11
    B
    12
    C
    13
    D
    14
    E
    15
    F
    PIM
    0 – 7
    • Up to 12 slots are available in PIM0 through PIM7.
    Note:The BRI card (BRI0/BRI1), which sends a clock signal to PLO of the MP card, must be mounted in the AP
    slots on PIM0.
    P
    W
    R
    LT00LT01LT02LT03LT04LT05LT06LT07LT08LT09LT10/AP0LT11/AP1LT12/AP2LT13/AP3LT14/AP4LT15/AP5
    AP6
    MP/FP/AP7BUS/AP8
    ATTENTIONContents
    Static Sensitive
    Handling
    Prec autions  R equire d 
    						
    							CHAPTER 4 ND-45857 (E)
    Page 46 Addendum-001
    Revision 3.1 AUGUST, 1998
    INSTALLATION
    4.2.2 Cable Connection via the MDF for ISDN with BRI
    Connect the cable to a CSU via the MDF as shown in Figure 3-15.
    Figure 3-16 shows LTC connector corresponds with the AP slots, and DTI pin assignment for each AP slot.
    Figure 3-17 shows an example of the cable connection when the BRI card is mounted in the AP0 slot of PIM0.
    Figure 3-15   Cable Connection via the MDF for ISDN with BRI
    NT1 MDF
    LTC1/LTC2 CONNECTORTWISTED-PAIR
    CABLE BRI BWBPBX
    MAX. 3280 ft. (1000 m)
    Note:The NT1 must be installed to interface with the network, and must be installed on the premises where the
    PBX is located. 
    						
    							ND-45857 (E) CHAPTER 3
    Page 47
    Revision 3.0
    INSTALLATION
    Figure 3-16   Location of the AP Slots and the LTC Connectors for BRI
    LT15/AP5FP/AP6MP/FP/AP7BUS/AP8
    LT14/AP4
    LT13/AP3
    LT12/AP2
    LT11/AP1
    LT 0 0 LT 0 1 LT 0 2 LT 0 9
    LT 0 4 LT 0 8
    LT 0 7
    LT 0 3 LT 0 6
    LT 0 5 LT10/AP0
    LT C 1
    LTC1 LTC2
    126
    LT 0 61RA26RB
    LT12/AP2 227 2TA27TB
    328 328
    429 429
    530
    LT 0 75RA30RB
    LT13/AP3 631 6TA31TB
    732 732
    833 833
    934
    LT 0 89RA34RB
    LT14/AP4 10 35 10 TA 35 TB
    11 36 11 36
    12 37 12 37
    13 38
    LT 0 913 RA 38 RB
    LT15/AP5 14 39 14 TA 39 TB
    15 40 15 40
    16 41 16 41
    17 RA 42 RB
    LT10/AP017 RA 42 RB
    AP6 18 TA 43 TB 18 TA 43 TB
    19 44 19 44
    20 45 20 45
    21 RA 46 RB
    LT11/AP121 46
    22 TA 47 TB 22 47
    23 48 23 48
    24 49 24 49
    25 50 25 50
    LTC1 LTC2
    LTC0 LTC2 
    						
    							CHAPTER 3 ND-45857 (E)
    Pag e 4 8
    Revision 3.0
    INSTALLATION
    Figure 3-17   Example of Cable Connection via the MDF for BRI
    43BA1 4342
    BA0 42
    18
    17
    MDF
    AA0 17
    AA1 18
    PIM0
    P BRI
    AP0LT C 1
    J
    RA
    RB
    TA
    TB
    SEND1
    34 32 T0-31
    33RECEIVE
    42 RB 17 RA
    43 TB 18 TA
    44 19
    45 20
    (P)
    17 RA 42 RB
    18 TA 43 TB
    19 44
    20 45
    LTC (J)
    1 LTC1 CONNECTOR
    2 MDF CONNECTOR
    31 32 33 34 35 36 37
    RA RB TA TB
    T0
    2 [LT10]
    TO CSU
    38 39 
    						
    							ND -4 5857 ( E)  CHAPTER 3
    IN STA LL AT ION
    END
    CAB LE CONNEC TION
    M OUNTING  IL C  CARD   SE E S ECTIO N 4.3 .2 
    						
    							CHAPTER 3 ND-45857 (E)
    Pag e 5 0
    Revision 3.0
    INSTALLATION
    4.3.1 Mounting ICH Card
    STEP 1: On the ICH (PN-SC02/SC03) card, set the switches as shown in Figure 3-19.
    Figure 3-19   Switch Settings on the ICH Card (1/2)
    MB
    RU N
    MB
    SW0
    SW
    ON
    OFF
    SET THE SENS SWITCH TO 
    MATCH THE AP NO. (04-15) 
    TO BE SET BY CM05.SENS
    : POSITION TO BE SET
    1 2
    3 4
    SENS
    DOPE1UP
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    DOPE0
    • PN-SC02
    Note:Firmware must be CD1.00 or higher. 
    						
    All NEC manuals Comments (0)