    							ND-45857 (E) CHAPTER 4
    Addendum-001 Page 137
    AUGUST, 1998 Revision 3.1
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Area Code + Local Office Code • YY=05
    00 > 214555
    Last 4 digits of telephone no. + 4 digit SPID • YY=30
    040 > 62040101
    041 > 62050101
    050 > 62060101
    051 > 62070101
    Set as ISDN trunk route.
    Answer signal arrives.
    Incoming connection signaling.
    Hooking signal sending to outside not 
    provided.
    Enable digit conversion.
    Disable trunk queuing outgoing.
    Assign as BRI trunk route.•
    •
    •
    •
    •
    •
    •YY=00
    10 > 00
    11 > 00
    YY=04
    10 > 2
    11 > 2
    YY=09
    10 > 08
    11 > 08
    YY=16
    10 > 0
    11 > 0
    YY=18
    10 > 0
    11 > 0
    YY=28
    10 > 0
    11 > 0
    YY=90
    10 > 2
    11 > 2
    Terminate BRI trunks to station for testing. • Y=0 & Y=1
    6204 > Sta. no.
    6205 > Sta. no.
    6206 > Sta. no.
    6207 > Sta. no.CM50
    CMAC
    A
    CM35
    CM76
    END 
    						
    							CHAPTER 4 ND-45857 (E)
    Page 138 Addendum-001
    Revision 3.1 AUGUST, 1998
    SYSTEM DATA PROGRAMMING
    BRI Trunks in PBX A are:
    Circuit 1: B1  (214) 555-6868
    B2   (214) 555-6869
    Circuit 2: B1  (214) 555-6870
    B2  (214) 555-6871
    Note:You must have this information prior to programming E-CCIS.
    • Home-Side Trunk Programming
    DESCRIPTION DATA
    Assign Home-Side trunks to even numbered 
    addresses.• YY=05
    3200 > D030
    3202 > D031
    3204 > D032
    3206 > D033
    Assign trunks to trunk routes. • YY=00
    030 > 30
    031 > 30
    032 > 30
    033 > 31
    Assign as Tie Line routes. • YY=00
    30 > 04
    31 > 04
    Set route as Dial Pulse.
    Answer signal arrives.
    Incoming connection signaling.
    Seize trunks by lowest numbered trunk.
    Assign as CCIS.•
    •
    •
    •
    •YY=01
    30 > 2
    31 > 2
    YY=04
    30 > 2
    31 > 2
    YY=09
    30 > 06
    31 > 06
    YY=83
    30 > 0
    YY=90
    0 > 0
    31 > 0CM07 START
    A
    CM30
    CM35 
    						
    							ND-45857 (E) CHAPTER 4
    Addendum-001 Page 139
    AUGUST, 1998 Revision 3.1
    SYSTEM DATA PROGRAMMING
    DESCRIPTION DATA
    Assign CCH Channel No.
    Assign as E-CCIS route.•
    •YY=91
    30 > 0
    31 > 0
    YYY=135
    30 > 0
    31 > 0
    Assign CIC no. • YY=35
    030 > 001
    031 > 002
    032 > 003CM35
    CM30
    A
    END 
    						
    							CHAPTER 4 ND-45857 (E)
    Page 140 Addendum-001
    Revision 3.1 AUGUST, 1998
    SYSTEM DATA PROGRAMMING
    • Mate-Side Trunk Programming
    DESCRIPTION DATA
    Assign Mate-Side trunks to odd numbered 
    addresses.• YY=05
    3201 > D040
    3203 > D041
    3205 > D042
    3207 > D043
    Assign trunks to trunk routes.
    Assign last 4 digits of telephone number in 
    PBX A.•
    •YY=00
    040 > 40
    041 > 41
    042 > 42
    043 > 43
    YY=19 
    040 > 6868
    041 > 6869
    042 > 6870
    043 > 6871
    Assign as Tie Line routes.
    Assign abbreviated codes to terminate call to 
    PBX A.
    Note:Terminating number and its memory allo-
    cation are assigned by CM 71 and CM 72.
    Release virtual tie line if there are no calls for a 
    predetermined time.
    Assign as E-CCIS route.•
    •
    •
    •YY=00
    40 > 04
    41 > 04
    42 > 04
    43 > 04
    YY=40
    40 > 00
    41 > 01
    42 > 02
    43 > 03
    YYY=127
    40 > 0
    41 > 0
    42 > 0
    43 > 0
    YYY=135
    40 > 0
    41 > 0
    42 > 0
    43 > 0
    CM07 START
    CM30
    CM35
    END 
    						
    							ND-45857 (E) CHAPTER 4
    Addendum-001 Page 141
    AUGUST, 1998 Revision 3.1
    SYSTEM DATA PROGRAMMING
    3.10.2 Program Termination for Incoming E-CCIS Calls
    3.10.3 Program Access Code/Terminating Number Assignment for Outgoing E-CCIS Calls
    3.10.4 Program Release Timer for Virtual Tie Lines (Home-Side & Mate-Side Trunks)DESCRIPTION DATA
    Convert received digits to Mate-Side trunks. • Y=0 & Y=1
    6204 > B040
    6205 > B041
    6206 > B042
    6207 > B043
    DESCRIPTION DATA
    Allocate memory to store the terminating num-
    bers of PBX B
    Note:In the stored number a trunk route access
    code must be used. E-CCIS will not work
    if an LCR access code is used.
    •
    •66 > 100004
    100 > 80,2145556868
    101 > 80,2145556869
    102 > 80,2145556870
    103 > 81,2145556871
    DESCRIPTION DATA
    Release timer for voice channels
    Release timer for CCH channel•
    •Y=0
    87 > 04
    Y=0
    89 > 08
    CM76 START
    END
    CM71 START
    END
    CM72
    CM41 START
    END 
    						
    							CHAPTER 4 ND-45857 (E)
    Page 142 Addendum-001
    Revision 3.1 AUGUST, 1998
    SYSTEM DATA PROGRAMMING
    3.10.5 CCH Data Assignment:
    Sense Wheel for PN-SC00 is set to 06.
    Originating Point Code for PBX  B is 00002.
    3.10.6 Alternative ISDN Route Assignment
    To provide an ISDN line as an alternative route when the call can not be connected through the virtual tie line,
    do the programming for Least Cost Routing. Refer to the NEAX2000 IVS Feature Programming Manual.
    For the call through the alternative ISDN route, the called number which is dialed by the caller is set to the sub-
    address.
    DESCRIPTION DATA
    Assign CCH card.
    • 06 > 11
    Assign CCH channel no. to CCH card.
    •YY=07
    0 > 06
    Provide the PBX with CCIS.
    •53 > 0
    Assign trunk to be used as CCH channel.
    Assign Originating Point Code.
    Assign Destination Point Code.
    Assign ACM Signal Waiting Timer.
    Assign E-CCIS for the CCH channel.•
    •
    •
    •
    •YY=00 
    0 > 043
    YY=01
    0 > 00002
    YY=02
    0 > 00001
    YY=10
    0 > 14
    YY=27
    0 > 0
    Assign CCH channel to which a signaling mes-
    sage is transferred according to the Destination 
    Point Code received.)• 0 > 00001CM05 START
    CM09
    CMA8
    CM06
    CMA7
    END 
    						
    							ND -4 5857 ( E)  CHAPTER 5
    CHAPTER 5  INSTA LLA TIO N T E S T 
    						
    							CHAPTER 5 ND-45857 (E)
    Pag e 1 44
    Revision 3.0
    INSTALLATION TEST
    Table 5-1  Alarm Indications on the PN-24DTA Card
    LEDLED INDICATION FAULT
    NORMAL FAULT CAUSE ACTION
    RUNFlash 
    (120IPM)OffDTI Trunk data is not 
    correctly assigned.1.Reset the MB switch.
    (Down®UP®Down)
    2.Confirm the program data 
    (CM05, CM07 YY = 01)
    CRC Off OnBit Error Rate exceeds the 
    predetermined value.Check the transmission line and external 
    equipment.
    PCM Off OnNo PCM signals arrive from 
    the distant office.1.Check to see if the DTI cable is cor-
    rectly connected.   
    2.Plug and unplug the DTI cards. Repeat 
    this two or three times.
    FRM Off OnFrame Alignment signals 
    from the distant office 
    cannot be received.Check the transmission line and external 
    equipment.
    RMT Off OnFrame Alignment signals 
    cannot be sent to the 
    opposite PBX.Replace the DTI card.
    AIS Off OnOpposite PBX is in the loop-
    back test.Check the opposite DTI card. 
    						
    							ND-45857 (E) CHAPTER 5
    Page 145
    Revision 3.0
    INSTALLATION TEST
    3.2 PLO Operation Test
    The following tests should be performed to confirm the PLO operation’s normality.
    • Clock Signal Generation Test
    • Clock Signal Synchronization Test To be performed when the PBX is a slave office.
    • Interoffice Synchronization Test
    3.2.1 Clock Signal Generation Test
    This test checks to see if the PLO keeps generating clock signals at the frequency of the previous master clock,
    when the external clock signal from the master office and sub-master office have stopped.
    To perform this test, an “In Service” transmission line is required.
    STEP 1: On all the DTI cards mounted in the PIM0, set the SW-1 and SW-2 to “OFF” to stop the external
    clock signal input.
    – The CLKIN lamp on the MP card goes out.
    STEP 2: Originate an outgoing call via DTI.
    STEP 3: After an outgoing connection via DTI has been established, confirm interoffice synchronization and
    speech quality with the following procedure.
    On the DTMF telephone set, keep pressing any dial button.
    Check to see if noise is periodically occurring with the DTMF signals
    coming from the calling station in the opposite office.
    Perform the above test again in the opposite direction.
    STEP 4: On all the DTI cards mounted in the PIM0, restore the SW-1 and SW-2 as the state before testing to
    input the external clock signals.
    – The CLKIN lamp on the MP card lights.
    If noise is periodically occurring, replace the MP card after checking the switch settings on the MP card,
    and perform the above test again.
    1
    2
    3 
    						
    							CHAPTER 5 ND-45857 (E)
    Pag e 1 46
    Revision 3.0
    INSTALLATION TEST
    3.2.2 Clock Signal Synchronization Test
    This test checks to see if the PLO keeps synchronizing with the external clock signals, when the external clock
    signals from the master/sub-master office has input again after it has stopped once.
    To perform this test, an “In Service” transmission line is required.
    (1) When providing one clock supply route (from a master office)
    STEP 1: On the DTI card extracting clock signals (DTI0), set the SW-1 and SW-2 to “OFF” to stop the exter-
    nal clock signal input.
    – The CLKIN lamp on the MP card goes out.
    STEP 2: Originate an outgoing call via DTI.
    STEP 3: After an outgoing connection via DTI has been established, confirm interoffice synchronization and
    speech quality with the following procedure.
    On the DTMF telephone set, keep pressing any dial button.
    Check to see if noise is periodically occurring with the DTMF signals
    coming from the calling station in the opposite office.
    Perform the above test again in the opposite direction.
    STEP 4: On the DTI card (DTI0), restore the SW-1 and SW-2 as the state before testing to input the external
    clock signals.
    – The CLKIN lamp on the MP card lights.
    STEP 5: Originate an outgoing call via DTI.
    STEP 6: After an outgoing connection via DTI has been established, confirm interoffice synchronization and
    speech quality with the procedure  –  shown in STEP 3.
    If noise is periodically occurring, replace the MP card after checking the switch settings on the MP card,
    and perform the above test again.