ND-45857 (E) CHAPTER 4 Addendum-001 Page 137 AUGUST, 1998 Revision 3.1 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Area Code + Local Office Code • YY=05 00 > 214555 Last 4 digits of telephone no. + 4 digit SPID • YY=30 040 > 62040101 041 > 62050101 050 > 62060101 051 > 62070101 Set as ISDN trunk route. Answer signal arrives. Incoming connection signaling. Hooking signal sending to outside not provided. Enable digit conversion. Disable trunk queuing outgoing. Assign as BRI trunk route.• • • • • • •YY=00 10 > 00 11 > 00 YY=04 10 > 2 11 > 2 YY=09 10 > 08 11 > 08 YY=16 10 > 0 11 > 0 YY=18 10 > 0 11 > 0 YY=28 10 > 0 11 > 0 YY=90 10 > 2 11 > 2 Terminate BRI trunks to station for testing. • Y=0 & Y=1 6204 > Sta. no. 6205 > Sta. no. 6206 > Sta. no. 6207 > Sta. no.CM50 CMAC A CM35 CM76 END
CHAPTER 4 ND-45857 (E) Page 138 Addendum-001 Revision 3.1 AUGUST, 1998 SYSTEM DATA PROGRAMMING BRI Trunks in PBX A are: Circuit 1: B1 (214) 555-6868 B2 (214) 555-6869 Circuit 2: B1 (214) 555-6870 B2 (214) 555-6871 Note:You must have this information prior to programming E-CCIS. • Home-Side Trunk Programming DESCRIPTION DATA Assign Home-Side trunks to even numbered addresses.• YY=05 3200 > D030 3202 > D031 3204 > D032 3206 > D033 Assign trunks to trunk routes. • YY=00 030 > 30 031 > 30 032 > 30 033 > 31 Assign as Tie Line routes. • YY=00 30 > 04 31 > 04 Set route as Dial Pulse. Answer signal arrives. Incoming connection signaling. Seize trunks by lowest numbered trunk. Assign as CCIS.• • • • •YY=01 30 > 2 31 > 2 YY=04 30 > 2 31 > 2 YY=09 30 > 06 31 > 06 YY=83 30 > 0 YY=90 0 > 0 31 > 0CM07 START A CM30 CM35
ND-45857 (E) CHAPTER 4 Addendum-001 Page 139 AUGUST, 1998 Revision 3.1 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign CCH Channel No. Assign as E-CCIS route.• •YY=91 30 > 0 31 > 0 YYY=135 30 > 0 31 > 0 Assign CIC no. • YY=35 030 > 001 031 > 002 032 > 003CM35 CM30 A END
CHAPTER 4 ND-45857 (E) Page 140 Addendum-001 Revision 3.1 AUGUST, 1998 SYSTEM DATA PROGRAMMING • Mate-Side Trunk Programming DESCRIPTION DATA Assign Mate-Side trunks to odd numbered addresses.• YY=05 3201 > D040 3203 > D041 3205 > D042 3207 > D043 Assign trunks to trunk routes. Assign last 4 digits of telephone number in PBX A.• •YY=00 040 > 40 041 > 41 042 > 42 043 > 43 YY=19 040 > 6868 041 > 6869 042 > 6870 043 > 6871 Assign as Tie Line routes. Assign abbreviated codes to terminate call to PBX A. Note:Terminating number and its memory allo- cation are assigned by CM 71 and CM 72. Release virtual tie line if there are no calls for a predetermined time. Assign as E-CCIS route.• • • •YY=00 40 > 04 41 > 04 42 > 04 43 > 04 YY=40 40 > 00 41 > 01 42 > 02 43 > 03 YYY=127 40 > 0 41 > 0 42 > 0 43 > 0 YYY=135 40 > 0 41 > 0 42 > 0 43 > 0 CM07 START CM30 CM35 END
ND-45857 (E) CHAPTER 4 Addendum-001 Page 141 AUGUST, 1998 Revision 3.1 SYSTEM DATA PROGRAMMING 3.10.2 Program Termination for Incoming E-CCIS Calls 3.10.3 Program Access Code/Terminating Number Assignment for Outgoing E-CCIS Calls 3.10.4 Program Release Timer for Virtual Tie Lines (Home-Side & Mate-Side Trunks)DESCRIPTION DATA Convert received digits to Mate-Side trunks. • Y=0 & Y=1 6204 > B040 6205 > B041 6206 > B042 6207 > B043 DESCRIPTION DATA Allocate memory to store the terminating num- bers of PBX B Note:In the stored number a trunk route access code must be used. E-CCIS will not work if an LCR access code is used. • •66 > 100004 100 > 80,2145556868 101 > 80,2145556869 102 > 80,2145556870 103 > 81,2145556871 DESCRIPTION DATA Release timer for voice channels Release timer for CCH channel• •Y=0 87 > 04 Y=0 89 > 08 CM76 START END CM71 START END CM72 CM41 START END
CHAPTER 4 ND-45857 (E) Page 142 Addendum-001 Revision 3.1 AUGUST, 1998 SYSTEM DATA PROGRAMMING 3.10.5 CCH Data Assignment: Sense Wheel for PN-SC00 is set to 06. Originating Point Code for PBX B is 00002. 3.10.6 Alternative ISDN Route Assignment To provide an ISDN line as an alternative route when the call can not be connected through the virtual tie line, do the programming for Least Cost Routing. Refer to the NEAX2000 IVS Feature Programming Manual. For the call through the alternative ISDN route, the called number which is dialed by the caller is set to the sub- address. DESCRIPTION DATA Assign CCH card. • 06 > 11 Assign CCH channel no. to CCH card. •YY=07 0 > 06 Provide the PBX with CCIS. •53 > 0 Assign trunk to be used as CCH channel. Assign Originating Point Code. Assign Destination Point Code. Assign ACM Signal Waiting Timer. Assign E-CCIS for the CCH channel.• • • • •YY=00 0 > 043 YY=01 0 > 00002 YY=02 0 > 00001 YY=10 0 > 14 YY=27 0 > 0 Assign CCH channel to which a signaling mes- sage is transferred according to the Destination Point Code received.)• 0 > 00001CM05 START CM09 CMA8 CM06 CMA7 END
ND -4 5857 ( E) CHAPTER 5 CHAPTER 5 INSTA LLA TIO N T E S T
CHAPTER 5 ND-45857 (E) Pag e 1 44 Revision 3.0 INSTALLATION TEST Table 5-1 Alarm Indications on the PN-24DTA Card LEDLED INDICATION FAULT NORMAL FAULT CAUSE ACTION RUNFlash (120IPM)OffDTI Trunk data is not correctly assigned.1.Reset the MB switch. (Down®UP®Down) 2.Confirm the program data (CM05, CM07 YY = 01) CRC Off OnBit Error Rate exceeds the predetermined value.Check the transmission line and external equipment. PCM Off OnNo PCM signals arrive from the distant office.1.Check to see if the DTI cable is cor- rectly connected. 2.Plug and unplug the DTI cards. Repeat this two or three times. FRM Off OnFrame Alignment signals from the distant office cannot be received.Check the transmission line and external equipment. RMT Off OnFrame Alignment signals cannot be sent to the opposite PBX.Replace the DTI card. AIS Off OnOpposite PBX is in the loop- back test.Check the opposite DTI card.
ND-45857 (E) CHAPTER 5 Page 145 Revision 3.0 INSTALLATION TEST 3.2 PLO Operation Test The following tests should be performed to confirm the PLO operation’s normality. • Clock Signal Generation Test • Clock Signal Synchronization Test To be performed when the PBX is a slave office. • Interoffice Synchronization Test 3.2.1 Clock Signal Generation Test This test checks to see if the PLO keeps generating clock signals at the frequency of the previous master clock, when the external clock signal from the master office and sub-master office have stopped. To perform this test, an “In Service” transmission line is required. STEP 1: On all the DTI cards mounted in the PIM0, set the SW-1 and SW-2 to “OFF” to stop the external clock signal input. – The CLKIN lamp on the MP card goes out. STEP 2: Originate an outgoing call via DTI. STEP 3: After an outgoing connection via DTI has been established, confirm interoffice synchronization and speech quality with the following procedure. On the DTMF telephone set, keep pressing any dial button. Check to see if noise is periodically occurring with the DTMF signals coming from the calling station in the opposite office. Perform the above test again in the opposite direction. STEP 4: On all the DTI cards mounted in the PIM0, restore the SW-1 and SW-2 as the state before testing to input the external clock signals. – The CLKIN lamp on the MP card lights. If noise is periodically occurring, replace the MP card after checking the switch settings on the MP card, and perform the above test again. 1 2 3
CHAPTER 5 ND-45857 (E) Pag e 1 46 Revision 3.0 INSTALLATION TEST 3.2.2 Clock Signal Synchronization Test This test checks to see if the PLO keeps synchronizing with the external clock signals, when the external clock signals from the master/sub-master office has input again after it has stopped once. To perform this test, an “In Service” transmission line is required. (1) When providing one clock supply route (from a master office) STEP 1: On the DTI card extracting clock signals (DTI0), set the SW-1 and SW-2 to “OFF” to stop the exter- nal clock signal input. – The CLKIN lamp on the MP card goes out. STEP 2: Originate an outgoing call via DTI. STEP 3: After an outgoing connection via DTI has been established, confirm interoffice synchronization and speech quality with the following procedure. On the DTMF telephone set, keep pressing any dial button. Check to see if noise is periodically occurring with the DTMF signals coming from the calling station in the opposite office. Perform the above test again in the opposite direction. STEP 4: On the DTI card (DTI0), restore the SW-1 and SW-2 as the state before testing to input the external clock signals. – The CLKIN lamp on the MP card lights. STEP 5: Originate an outgoing call via DTI. STEP 6: After an outgoing connection via DTI has been established, confirm interoffice synchronization and speech quality with the procedure – shown in STEP 3. If noise is periodically occurring, replace the MP card after checking the switch settings on the MP card, and perform the above test again. 1 2 3 13