    							ND-45857 (E) CHAPTER 3
    Page 33
    Revision 3.0
    INSTALLATION
    STEP 2: Mount the DTI card and the DCH card in AP slots on PIM0-PIM7.
    After mounting the card, set the SENS switch to match an unequipped slot number in CM05. And set
    the MB switch to down position to put the card in service. For details on mounting locations, refer to
    the Circuit Card Manual.
    Figure 3-5   Mounting Location of DTI/DCH Card
    DTI/DCH
    CARDBUILT-IN BATTERY
    • Mount DTI card in the AP slots (AP0-AP6).
    • Mount DCH card in the AP slots (AP0-AP8).
    • Set the SENS switch on the DTI card and DCH card to match an unequipped slot number in CM05
    as shown below.
    SLOT NUMBER
    SWITCH SETTING VALUE
    04
    4
    05
    5
    06
    6
    07
    7
    08
    8
    09
    9
    10
    A
    11
    B
    12
    C
    13
    D
    14
    E
    15
    F
    PIM
    0 – 7
    • Up to 12 slots are available in PIM0 through PIM7.
    Note:The DTI card (DTI0, DTI1), which sends a clock signal to PLO of the MP card, must be mounted in the
    AP slots on PIM0.
    P
    W
    R
    LT00LT01LT02LT03LT04LT05LT06LT07LT08LT09LT10/AP0LT11/AP1LT12/AP2LT13/AP3LT14/AP4LT15/AP5
    AP6
    MP/FP/AP7BUS/AP8
    ATTENTIONContents
    Static Sensitive
    Handling
    Prec autions  R equire d 
    						
    							CHAPTER 3 ND-45857 (E)
    Page 34 Addendum-001
    Revision 3.1 AUGUST, 1998
    INSTALLATION
    4.1.2 Selection of PLO in MP Card
    STEP 1: On the MP (PN-CP00/CP00-B/CP03) card, set the switches as shown in Figure 3-6.
    Figure 3-6   Switch Settings on the MP Card (1/3)
    RU N
    SW2
    ON 
     
     
     
     
     
     
     
    OFF
    0: ON LINE MODE
    : POSITION TO BE SET
    1 2 3 4
    JP0
    SW3
    CLKIN
    JP0
    RS
    ON: KF MODE
    OFF: PF/MF MODE (STANDARD SETTING
    FOR U.S.A.)
    SW1
    SW2
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    • PN-CP00
    • WHEN USING THE INTERNAL PLO • WHEN USING THE PLO CARD
    SW2-2 SW2-3 SW2-2 SW2-3
    OFF OFF : 1.5 MHz CLOCK
      (FOR 24-DTI)OFF ON
    ON OFF : 192 KHz CLOCK
      (FOR BRTA)
    OFF ON : 2 MHz CLOCK
      (FOR 2BRTC)
    ON ON : NOT USED
    • WHEN NOT USING THE INTERNAL PLO
    AND THE PLO CARD
    SW2-2 SW2-3
    OFF OFF
    RIGHT: NORMAL 
    OPERATION
    : POSITION TO BE SETSW3
     
    
    
     
    						
    							ND-45857 (E) CHAPTER 3
    Addendum-001 Page 35
    AUGUST, 1998 Revision 3.1
    INSTALLATION
    Figure 3-6  Switch Settings on the MP Card (2/3)
    SW3
    RUN
    SW1
    SW2
    CLKIN
    JP0
    0: ON LINE MODE
    JP0
    :  POSITION TO BE SET
    •  PN-CP00-B
    • WHEN USING THE INTERNAL PLO • WHEN USING THE PLO CARD
    SW2-2 SW2-3 SW2-2 SW2-3
    OFF OFF : 1.5 MHz CLOCK
      (FOR 24-DTI)OFF ON
    ON OFF : 192 KHz CLOCK
      (FOR BRTA)
    OFF ON : 2 MHz CLOCK
      (FOR 2BRTC)
    ON ON : NOT USED
    • WHEN THE INTERNAL PLO AND THE
    PLO CARD ARE NOT USED
    SW2-2 SW2-3
    OFF OFF
    SW2OFF
    ON 8
     
    7 
    6 
    5 
    4 
    3 
    2 
    1
    : POSITION TO   BE SET
    ON: KF MODE
    OFF: PF/MF MODE (STANDARD SETTING
    FOR U.S.A.)
    UP: NORMAL  OPERATIONSW3
     
    
    
    
    
    
    
    
    
    
     
    
    
     
    						
    							CHAPTER 3 ND-45857 (E)
    Page 36 Addendum-001
    Revision 3.1 AUGUST, 1998
    INSTALLATION
    Figure 3-6  Switch Settings on the MP Card (3/3)
    STEP 2: Mount the MP card on the MP slot of PIM0.
    SW2SW2
    OFFON
    4
     
    3 2 1 
     
    SW3: POSITION TO   BE SET
    :  POSITION TO BE SET
     0: ON LINE MODE
    ON:   KF MODE
    OFF:  PF/MF MODE (STANDARD 
    SETTING FOR U.S.A.) 
    • WHEN USING THE INTERNAL PLO
    SW2-2 SW2-3
    OFF OFF : 1.5 MHz CLOCK
    (FOR 24-DTI)
    ON OFF : 192 KHz CLOCK
    (FOR BRTA)
    OFF ON : 2 MHz CLOCK
    (FOR 2BRTC)
    ON ON : NOT USED
    • WHEN USING THE PLO CARD
    SW2-2 SW2-3
    OFF ON
    • WHEN NOT USING THE INTERNAL PLO AND THE
    PLO CARD
    SW2-2 SW2-3
    OFF OFF
    ON : USING RS 1 PORT FOR BUILT-IN MODEM
    OFF : USING RS 1 PORT FOR RS-232C
    JP0
    JP1
    VR
    JP0
    UP: NORMAL OPERATION
    JP1
    UP:  USING INTERNAL HOLD TONE
    DOWN: USING EXTERNAL HOLD TONE SOURCE
    SW3
    VR
    20
    0
     
    
    
    
    
    
    
    
     
    
    
    
     
    
    
    
     0
    •  PN-CP03
    VARIABLE RESISTER 
    FOR EXTERNAL HOLD 
    TONE SOURCE
    (0-20K
    W - CLOCKWISE) 
    						
    							ND-45857 (E) CHAPTER 3
    Addendum-001 Page 37
    AUGUST, 1998 Revision 3.1
    INSTALLATION
    4.1.3 Cable Connection via the MDF for ISDN with PRI
    When using a twisted-pair cable, connect the cable to a CSU via the MDF as shown in Figure 3-7.
    Figure 3-8 shows LTC connector corresponds with the AP slots, and DTI pin assignment for each AP slot, and
    Figure 3-9 shows an example of the cable connection when the DTI card is mounted in the AP0 slot of PIM0.
    Figure 3-7   Cable Connection via the MDF for ISDN with PRI
    CSU MDF
    TWISTED-PAIR
    CABLE BWBPBX
    (PIM0 - PIM7)
    MAX. 200 m (655 ft.)
    LTC1/LTC2 CONNECTOR
    (SEE FIGURES 3-8 AND 3-9) DTI
    Note:The CSU must be installed to interface with the network, and must be installed on the premises where the PBX
    is located. 
    						
    							CHAPTER 3 ND-45857 (E)
    Pag e 3 8
    Revision 3.0
    INSTALLATION
    Figure 3-8   Location of the AP Slots and the LTC Connectors for DTI
    126
    LT061RA26RB
    LT12/AP2 2 27 2 TA 27 TB
    328 328
    429 429
    530
    LT075RA30RB
    LT13/AP3 6 31 6 TA 31 TB
    732 732
    833 833
    934
    LT089RA34RB
    LT14/AP4 10 35 10 TA 35 TB
    11 36 11 36
    12 37 12 37
    13 38
    LT0913 RA 38 RB
    LT15/AP5 14 39 14 TA 39 TB
    15 40 15 40
    16 41 16 41
    17 RA 42 RB
    LT10/AP017 RA 42 RB
    AP6 18 TA 43 TB 18 TA 43 TB
    19 44 19 44
    20 45 20 45
    21 RA 46 RB
    LT11/AP121 46
    22 TA 47 TB 22 47
    23 48 23 48
    24 49 24 49
    25 50 25 50
    LTC0 LTC2LTC1 PIM
    0 - 7P
    W
    R
    LTC1 LTC2
    LT15/AP5FP/AP6MP/FP/AP7BUS/AP8
    LT14/AP4
    LT13/AP3
    LT12/AP2
    LT11/AP1
    LT00 LT01
    LT02 LT09
    LT04 LT08
    LT07
    LT03 LT06
    LT05 LT10/AP0 
    						
    							ND-45857 (E) CHAPTER 3
    Page 39
    Revision 3.0
    INSTALLATION
    Figure 3-9   Example of Cable Connection via the MDF for DTI
    TO
    PIM0
    PN-24DTA/24DTA-A
    RECEIVE
    SEND
    TO CSU JP MDFLT C 1
    12
    1
    2
    39 38 37 36 35 34 33 32 31
    TB TA RB RA
    RA
    RB
    TA
    TB T0-31
    32
    33
    34 AA0
    BA0
    AA1
    BA117
    42
    18
    4317
    42
    18
    43
    17
    18
    19
    20RA
    TA42
    43
    44
    45RB
    TB42
    43
    44
    4517
    18
    19
    20RA
    TA RB
    TB LTC1 CONNECTOR
    LTC (J) (P)
    MDF CONNECTOR AP0
    [LT10] 
    						
    							CHAPTER 3 ND-45857 (E)
    Page 40 Addendum-001
    Revision 3.1 AUGUST, 1998
    INSTALLATION
    4.1.4 Mounting PLO Card
    STEP 1: On the PLO (PN-CK00) card, set the switches as shown in Figure 3-10.
    Figure 3-10   Switch Settings on the PLO Card
    STEP 2: On the MP card, set the SW2-2 to OFF and SW2-3 to ON.
    MB
    SW
    SYNC
    PLO0
    PLO1
    OFF
    ON 8 
    7 
    6 
    5 
    4 
    3 
    2 
    1
    SW0MB
    : POSITION TO 
      BE SET
    UP
    ALM
    DRFT
    ATTENTIONContents
    Static Sensitive
    Handling
    Pr ec autions  Re quire d
    • SELECTION OF PLO 0 • SELECTION OF PLO 1
    SW0-1 SW0-2 SW0-3 SW0-4
    ON ON : 2 MHz CLOCK
      (30 DTI/2BRTC)ON ON
    OFF ON : 1.5 MHz CLOCK
      (24 DTI)OFF ON
    ON OFF : 192 KHz CLOCK
      (BRTA)ON OFF
    OFF OFF : NOT USED OFF OFF 
    						
    							ND-45857 (E) CHAPTER 3
    Page 41
    Revision 3.0
    INSTALLATION
    STEP 3: Mount the PLO (PN-CK00) card in an AP slot on PIM0
    After mounting the card, set the MB switch to down position to put the card in service. For details on
    mounting locations, refer to the Circuit Card Manual.
    Figure 3-11   Mounting Location of the PLO Card
    PIM0 
    LT00 LT01
    LT02 LT03 LT04 LT05 LT06 LT07 LT08
    LT09 LT10/AP0
    LT11/AP1
    LT12/AP2 LT13/AP3 LT14/AP4 LT15/AP5AP6 MP/FP/AP7BUS/AP8
    PN-CK00BUILT-IN BATTERY
    PWR
    • Mount the PN-CK00 card in an AP slot (AP0-AP6) on PIM0. 
    CARD
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3  ND -4 5857 ( E)
    IN STA LLA TION
    E N D
    CABLE CONNEC TION
    S E LEC TIO N  OF P LO  IN
    MOUNTI NG P LO CARD
    N ote :  PLO ca rd (P N-CK00 ) i s  r e qu ir e d  when th e P B X is  a ma ste r o ffic e, or wh en  th e P B X r eq uir e s to  int erfa ce 
    						