ND-45857 (E) CHAPTER 3 Page 23 Revision 3.0 CHAPTER 3 INSTALLATION 1. GENERAL This chapter details the installation procedure and work contents involved in providing ISDN to the PBX. 2. PRECAUTION IN HANDLING The installer must wear the grounded wrist strap to protect the circuit card from static electricity, when handling cards, and the installer must engage in the work on a grounded conductive work surface. (See Figure 3-1). Figure 3-1 Static Electricity Precautions (1/2) CARD FRONT PBX WRIST STRAP • WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD • WHEN HOLDING A CIRCUIT CARD FRAME GROUND SCREW CONNECT THE GROUND WIRE TO THE FRAME EARTH OF THE EQUIPMENT. NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS.
CHAPTER 3 ND-45857 (E) Pag e 2 4 Revision 3.0 INSTALLATION Figure 3-1 Static Electricity Precautions (2/2) The mark shown below is attached to the sheet for the work in which circuit cards are handled. When engaging in such work, the installer must be careful not to cause damage by static electricity. WEAR A WRIST STRAP AND PERFORM THE WORK ON A GROUNDED CONDUCTIVE WORK SURFACE. WHEN CARRYING A CIRCUIT CARD AROUND, KEEP THE CARD IN THE CONDUCTIVE POLYETHYLENE BAG. CONDUCTIVE POLYETHYLENE BAG CIRCUIT CARDCIRCUIT CARD • WHEN SETTING SWITCHES ON A CIRCUIT CARD • WHEN CARRYING A CIRCUIT CARD AT T E N T I O NContents Static Sensitive Handling Precautions Required
ND-45857 (E) CHAPTER 3 Page 25 Revision 3.0 INSTALLATION CARD FRONT PBX NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS. The installer must hold the edge of the circuit card, when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. CAUTION
CHAPTER 3 ND-45857 (E) Page 26 Addendum-001 Revision 3.1 AUGUST, 1998 INSTALLATION 3. REQUIRED EQUIPMENT 3.1 Required Equipment for ISDN with PRI Table 3-1 below shows the equipment required when providing ISDN with Primary Rate Interface to the system. Note:PLO card (PN-CK00) is required when the PBX needs to interface with two clock supply routes with different frequen- cies, e.g., DTI Trunk (1.544 MHz) and BRI Trunk (192 KHz or 2 MHz). For example: T1 at 1.544 MHz, and 192 KHz or 2 MHz for BRI Trunks: In this condition a PLO card is required. 3.2 Required Equipment for ISDN with BRI Table 3-2 shows the equipment required when providing ISDN with Basic Rate Interface to the system. Note:PLO card (PN-CK00) is required when the PBX needs to interface with two clock supply routes with different frequen- cies, e.g., DTI Trunk (1.544 MHz) and BRI Trunk (192 KHz or 2 MHz). For example: T1 at 1.544 MHz, and 192 KHz or 2 MHz for BRI Trunks: In this condition a PLO card is required. Table 3-1 Required Equipment for ISDN with PRI EQUIPMENT DESCRIPTION QUANTITY REMARKS PN-24DTA/24DTA-A (DTI) 24-channel DTI card N N: 1 – 5 PN-SC01 (DCH) D-channel handler card N N: 1 – 5 PN-CK00 (PLO) PLO Card 1 Note Table 3-2 Required Equipment for ISDN with BRI EQUIPMENT DESCRIPTION QUANTITY REMARKS PN-BRTA (BRI) 2-channel BRI card (1 BRI trunk)N N: 1 – 12 PN-2BRTC (BRI) 4-channel BRI card (2 BRI trunks)N N: 1 – 12 PN-CK00 (PLO) PLO Card 1 Note PN-SC02/SC03 (ICH) ISDN Channel Handler Card N N: 1 – 12 PN-2ILCA (ILC) ISDN Line Circuit Card N N: 1 – 12 (Using SC02) 1 – 48 (Using SC03)
CHAPTER 3 ND-45857 (E) Page 28 Addendum-001 Revision 3.1 AUGUST, 1998 INSTALLATION 4. INSTALLATION PROCEDURE 4.1 Installation Procedure for ISDN with PRI Perform the installation procedure shown in Figure 3-2. Note:When requiring Call Recording of ISDN call, execute the installation procedure for SMDR. For details, refer to the SMDR System Manual. Figure 3-2 Installation Procedure for ISDN with PRI END START MOUNTING DTI AND DCH CARD SELECTION OF PLO IN MP CARD CABLE CONNECTION VIA MDFSEE SECTION 4.1.1 SEE SECTION 4.1.2 SEE SECTION 4.1.3 MOUNTING PLO CARDSEE SECTION 4.1.4 Note Note:PLO card (PN-CK00) is required when the PBX needs to interface with two clock supply routes with different frequencies, such as 1.544 MHz, and 192 KHz or 2 MHz.
ND -4 5857 ( E) CHAPTER 3 IN STA LL AT ION MB S E NS SW SWO FF S ET THE KN OB TO M ATCH THE 8 JP SNEU TRA L G ROUND IN G ON LINE IM PE DAN CE: NEU TRAL G ROUND ING ON J P S JP R 0 SW -5 SW -6 SW -7 CABLE LE NGTH JP R 1 JP R1 JP R0 ATTE NTIO N : P OSI TIO N TO BE SET
CHAPTER 3 ND-45857 (E) Pag e 3 0 Revision 3.0 INSTALLATION Figure 3-3 Switch Settings on the DTI Card (2/2) SEE Table 3-4 JPS JPR1 JPR0MB SW CRC PCM FRM AIS [RMT] RMT [AIS] BLOFF ON 8 7 6 5 4 3 2 1 JPS JPR0 SENS RUN SWMB SET THE KNOB TO MATCH THE SLOT NO. (04-15) TO BE SET BY CM05. : POSITION TO BE SET NEUTRAL GROUNDING ON THE TRANSMIT LINE: RIGHT : NOT PROVIDED (OPEN) LEFT : PROVIDED (GROUND) NEUTRAL GROUNDING ON THE RECEIVE LINE: RIGHT : PROVIDED (GROUND) LEFT : NOT PROVIDED (OPEN)SW-5 ON ON ON ON OFF OFFSW-6 ON ON OFF OFF ON OFFSW-7 ON OFF ON OFF ON OFFCABLE LENGTH : POSITION TO BE SET SIGNAL IS NOT SENT 0 – 40 m (0 – 131 ft.) 40 – 80 m (131 – 262 ft.) 80 – 120 m (262 – 393 ft.) 120 – 160 m (393 – 524 ft.) 160 – 200 m (524 – 656 ft.) UP JPR1 LINE IMPEDANCE: RIGHT : NOT USED LEFT : 100 OHMS • PN-24DTA-A RIGHT : FACTORY TESTING LEFT : NORMAL OPERATIONMAS AISSAIS SIGNAL SENDING WHEN MAKE-BUSY OR POWER ON: RIGHT : SENT OUT LEFT : NOT SENT OUT AISS MAS [ ]: CARD ISSUE No. 5A OR EARLIERSENS
ND-45857 (E) CHAPTER 3 Page 31 Revision 3.0 INSTALLATION Table 3-4 Switch Settings for SW-1 and SW-2 on the DTI Card DTI0 DTI1 DTI2 DTI3 DTI4 REMARKS SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 When only one DTI is providedON OFFTo send a clock signal to PLO0 of the MP card. When more than one DTI is provided ON OFF OFF ON OFF OFF OFF OFF OFF OFFTo send a clock signal via DTI1 to PLO1 of the MP/PLO card, when a clock signal via DTI0 is not supplied due to a transmission line failure. (The clock supply route 0 via DTI0 is automatically changed to the clock supply route 1 via DTI1.) No. of DTI SW CONDITIONS
CHAPTER 3 ND-45857 (E) Pag e 3 2 Revision 3.0 INSTALLATION • When providing the DCH card: Figure 3-4 Switch Settings on the DCH Card MB UP SW0 ONOFF SET THE KNOB TO MATCH THE AP NO. (04-15) TO BE SET BY CM05.SENS : POSITION TO BE SET 4 = POSITION TO BE SET. 3 1 12345678 ON SW1 SENS RU N MB SW0 LC LPB ATTENTIONContents Static Sensitive Handling Precautions Required ON OFF: NORTHERN TELECOM INTERFACE : AT&T INTERFACE ON OFF: DELETE FIRST THREE DIGITS : NO DELETION 2 (011) FROM INTERNATIONAL CALLS