Home > NEC > Communications System > NEC Neax2000 Ivs Feature Programming Manual

NEC Neax2000 Ivs Feature Programming Manual

Here you can view all the pages of manual NEC Neax2000 Ivs Feature Programming Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 431

CHAPTER 2 ND-45670 (E)
Pag e 4 02
Revision 2.0
TRUNK-TO-TRUNK CONNECTION
DESCRIPTION DATA
Assign the Service Restriction Class C to each 
station.• YY = 07
(1) X-XXXX:Primary Extension No.
(2) XX:Service Restriction Class C (00-15)
Provide the switch hook flash capability dur-
ing C.O. line connection, to the required sta-
tions.• YY = 90, 91
(1) 00-15:Service Restriction Class C
(2) 1 :Allowed
Specify the combination of trunk routes al-
lowing the Trunk to Trunk Connection.(1) XX
 XX
Incoming trunk...

Page 432

ND-45670 (E) CHAPTER 2
Page 403
Revision 2.0
TRUNK-TO-TRUNK CONNECTION
DESCRIPTION DATA
Provide the system with Trunk to Trunk Con-
nection when no release signal arrives from 
the incoming trunk route and answer signal ar-
rives from the outgoing trunk route.(1) 324
(2) 0/1 :Available/Not available
Provide the system with Trunk to Trunk Con-
nection transferred by a station or an atten-
dant, when no answer signal arrives and 
release signal arrives from the outgoing trunk 
route.(1) 028
(2) 0/1...

Page 433

CHAPTER 2 ND-45670 (E)
Pag e 4 04
Revision 2.0
TRUNK-TO-TRUNK CONNECTION
To provide the AMP trunk for Trunk-to-Trunk Connection (1500 Series Enhancement):
DESCRIPTION DATA
Assign the Card Number of the AMP trunk 
(PN-2AMP).
Maximum of two digits are available.
Note:The AMP card number must be
assigned to both of the first LEN
(Level 0) and the third LEN (Level 2)
of each slot.(1) LEN (0000-0511)
(2) Card No. of AMP trunk
C100-C115 : For PIM0/1
C116-C131 : For PIM2/3
C132-C147 : For PIM4/5
C148-C163 : For...

Page 434

ND-45670 (E) CHAPTER 2
Page 405
Revision 2.0
TRUNK-TO-TRUNK CONNECTION
DESCRIPTION DATA
Select the Tone Disabler’s mode on each AMP 
pattern.• YY=04
(1) 00-14: AMP pattern No. 00-14
(2) 0:G164
1 : G165
Specify the Detect Timing of Tone Disabler on 
each AMP pattern.• YY=05
(1) 00-14: AMP pattern No. 00-14
(2) 0:0 sec.
1 : 2 sec.
Specify the channels connected to each AMP 
pattern.• YY=06
(1) 00-14: AMP pattern No. 00-14
(2) 0:Incoming route: Tie Line
Outgoing route: C.O. Line
1 :Incoming route: C.O....

Page 435

CHAPTER 2 ND-45670 (E)
Pag e 4 06
Revision 2.0
UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
PROGRAMMING
To activate UCD:
DESCRIPTION DATA
For each UCD Group, assign station numbers, 
one by one, in the order of hunting. 
Note:Up to 60 stations can be assigned
into a single UCD group.
Example:
 For setting Station Numbers 200, 
201, 202 into one UCD Group. 
1st Operation (1) 200 
(2) 200
2nd Operation(1) 201
(2) 202
3rd Operation (1) 202
(2) 200•Y = 0
(1) X-XXXX (Station No.)
(2) X-XXXX (Another Station...

Page 436

ND-45670 (E) CHAPTER 2
Page 407
Revision 2.0
UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
DESCRIPTION DATA
• Y = 6 (Tie Line Incoming Call) 
(1) X-XXXX (Pilot Station No. of the UCD 
Group)
(2) 0/1 : Not to be provided/To be provid-
ed 
• Y = 7 (DID Call) 
(1) X-XXXX (Pilot Station No. of the UCD 
Group)
(2) 0/1 :Not to be provided/To be 
provided
• Y=B (Designation of the number of 
queuing in each UCD group)
(1) X-XXXX (Pilot Station No. of the UCD 
Group)
(2) 0/1 : To be provided (See CM42-16)/
Not...

Page 437

CHAPTER 2 ND-45670 (E)
Pag e 4 08
Revision 2.0
UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
DESCRIPTION DATA
Specify the processing for an incoming call 
when all UCD Stations are busy.(1) 212 
(2) 0/1 :Busy Tone Connection /Queuing
Specify the processing for a held call after set-
ting the UCD Busy-Out.(1) 214 (For the held Call from Tie Line)
(2) 0/1 :Reconnected by Switch Hook 
Flash/Disconnected 
(1) 215 (For the held call from C.O. Line)
(2) 0/1 :Reconnected by Switch Hook 
Flash/Disconnected...

Page 438

ND-45670 (E) CHAPTER 2
Page 409
Revision 2.0
UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
To provide the delay announcement for UCD:
DESCRIPTION DATA
Assign a Digital Announcement Trunk Cir-
cuit No. to each LEN No.(1) 0000-0511 (LEN No.)
(2) EB000-EB127 (Digital Announcement 
Trunk Circuit No.)
Assign the Class of Service for Digital An-
nouncement Trunk Access (Record/Replay/
Delete) to the required station.• CM12 YY=02
(1) X-XXXX: Station No.
(2) XX
XX
*a 
*a: Service Restriction Class (A)
(00-15 )
•...

Page 439

CHAPTER 2 ND-45670 (E)
Pag e 4 10
Revision 2.0
UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
DESCRIPTION DATA
Assign an access code to record, replay, and 
delete the Digital Announcement Trunk.• Y=0-3 (Numbering Plan Group 0-3)
(1) X-XXXX: Access code
(2) A00: Record
A01: Replay
A02: Delete
When transferring the call to an extension or 
Attendant after the 1st interval time of UCD 
Delay Announcement, assign the destination.
Note:This command is only effective when
CM17, Y=A is set to 0 (to be sent pe-...

Page 440

ND-45670 (E) CHAPTER 2
Page 411
Revision 2.0
UNIFORM CALL DISTRIBUTION (UCD) WITH OVERFLOW
To monitor a UCD call, with or without a Warning Tone:
DESCRIPTION DATA
Specify the warning tone sent to connected 
parties (in two-way calling) when monitoring.(1) 259 
(2) 0: No Tone
1 : One Warning Tone 
Assign the Class of Service for monitoring 
stations. • CM12 YY = 02 
(1) X-XXXX: Station number
(2) XX
XX
*a: Service Restriction Class (A) (00-
15 )
• CM15 YYY = 103 
(1) XX: [Service Restriction Class (A)...
Start reading NEC Neax2000 Ivs Feature Programming Manual